Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation

被引:46
|
作者
Koppara, Tobias [1 ]
Joner, Michael [1 ]
Bayer, Gerd [2 ]
Steigerwald, Kristin [1 ]
Diener, Tobias [2 ]
Wittchow, Eric [2 ]
机构
[1] Deutsch Herzzentrum Munich, D-80636 Munich, Germany
[2] BIOTRONIK SE & Co KG, Erlangen, Germany
关键词
Porcine model; sirolimus-eluting stents; restenosis; POOLED ANALYSIS; DURABLE POLYMER; CLINICAL-OUTCOMES; RELEASE PROFILES; COATED STENTS; FOLLOW-UP; IN-VITRO; DRUG; RESTENOSIS; TRIAL;
D O I
10.1160/TH12-01-0043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biodegradable stent coatings were recently introduced as a potential solution to overcome sustained inflammatory responses observed with permanent polymer-based drug-eluting stents. In a preliminary study, selected biodegradable or permanent polymer-based sirolimus-eluting stent (SES) formulations were screened for effectiveness in comparison to bare metal stents (BMS) at 28 days. Subsequently, the most favourable SES formulation was compared to commercially available SES (Cypher (TM)) at 28,90 and 180 days to investigate the histopathologic response as well as tissue, blood and organ pharmacokinetics. Overlapping SES implantation was conducted to evaluate vascular healing at 28 days in this particular setting. SES with biodegradable poly (L-lactide) polymer (PLLA) or poly(lactide-co-glycolide) showed the most favourable outcome with regards to reductions in neointimal area in comparison to BMS at 28 days. The PLLA SES showed a similar reduction in neointimal area compared to Cypher (TM) at 28 days, with significant greater reductions at 90 and 180 days (1.7 +/- 0.7 mm(2) vs. 3.1 +/- 1.5 mm(2), p=0.03 and 1.8 +/- 1.2 mm(2) vs. 3.0 +/- 1.5 mm(2), p=0.01, respectively). Sirolimus vascular tissue concentrations were detectable up to 90 days following implantation. Overlapping stented segments showed favourable histopathologic results with respect to fibrin deposition and endothelialisation at 28 days. In conclusion, the use of PLLA as drug-eluting matrix resulted in mild inflammatory responses in the presence of effective sirolimus tissue concentrations. The greater efficacy observed at long-term follow-up in PLLA SES compared to Cypher (TM) may be a multifactorial result of stent design, polymer biocompatibility and improved release kinetics.
引用
收藏
页码:1161 / 1171
页数:11
相关论文
共 50 条
  • [21] Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model
    Carter, AJ
    Aggarwal, M
    Kopia, GA
    Tio, F
    Tsao, PS
    Kolata, R
    Yeung, AC
    Llanos, G
    Dooley, L
    Falotico, R
    CARDIOVASCULAR RESEARCH, 2004, 63 (04) : 617 - 624
  • [22] Vascular response and mechanical integrity of the new biodegradable polymer coated sirolimus-eluting PROLIM stent implanted in porcine coronary arteries
    Milewski, Krzysztof
    Gorycki, Bogdan
    Buszman, Piotr P.
    Jelonek, Michal
    Beaudry, Diane
    Lapointe, Jean-Martin
    Guy, Louis-Georges
    Abusamra, Motaz
    Pajak, Jacek
    Kinasz, Wojciech
    Wojakowski, Wojciech
    Leclerc, Guy
    Gil, Robert J.
    Buszman, Pawel E.
    KARDIOLOGIA POLSKA, 2012, 70 (07) : 703 - 711
  • [23] Early thrombogenicity of coronary stents: comparison of bioresorbable polymer sirolimus-eluting and bare metal stents in an aortic rat model
    Verhaegen, Carole
    Kautbally, Shakeel
    Zapareto, Diego Castanares
    Brusa, Davide
    Courtoy, Guillaume
    Aydin, Selda
    Bouzin, Caroline
    Oury, Cecile
    Bertrand, Luc
    Jacques, Pascal J.
    Beauloye, Christophe
    Horman, Sandrine
    Kefer, Joelle
    AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE, 2020, 10 (02): : 72 - 83
  • [24] Ultrathin, Biodegradable-Polymer Sirolimus-Eluting Stent vs Thin, Durable-Polymer Everolimus-Eluting Stent
    Nakamura, Masato
    Kadota, Kazushige
    Nakagawa, Yoshihisa
    Tanabe, Kengo
    Ito, Yoshiaki
    Amano, Tetsuya
    Maekawa, Yuichiro
    Takahashi, Akihiko
    Shiode, Nobuo
    Otsuka, Yoritaka
    Kawasaki, Tomohiro
    Hikichi, Yutaka
    Shite, Junya
    Kozuma, Ken
    Iijima, Raisuke
    Murakami, Yoshitaka
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (13) : 1324 - 1334
  • [25] Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography
    Tada, Tomohisa
    Kastrati, Adnan
    Byrne, Robert A.
    Schuster, Tibor
    Cuni, Rezarta
    King, Lamin A.
    Cassese, Salvatore
    Joner, Michael
    Pache, Jurgen
    Massberg, Steffen
    Schoemig, Albert
    Mehilli, Julinda
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (03) : 495 - 504
  • [26] Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations
    Costopoulos, Charis
    Latib, Azeem
    Naganuma, Toru
    Sticchi, Alessandro
    Ferrarello, Santo
    Regazzoli, Damiano
    Chieffo, Alaide
    Figini, Filippo
    Carlino, Mauro
    Montorfano, Matteo
    Naim, Charbel
    Kawaguchi, Masanori
    Gerasimou, Argyrios
    Giannini, Francesco
    Godino, Cosmo
    Colombo, Antonio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (06) : 889 - 895
  • [27] Efficacy and safety of a biodegradable polymer sirolimus-eluting stent in primary percutaneous coronary intervention: a randomized controlled trial
    Li, Qiang
    Tong, Zichuan
    Wang, Lefeng
    Zhang, Jianjun
    Ge, Yonggui
    Wang, Hongshi
    Li, Weiming
    Xu, Li
    Ni, Zhuhua
    Yang, Xinchun
    ARCHIVES OF MEDICAL SCIENCE, 2013, 9 (06) : 1040 - 1048
  • [28] Late neointimal volume reduction is observed following biodegradable polymer-based drug eluting stent in porcine model
    Ijichi, Takeshi
    Nakazawa, Gaku
    Torii, Sho
    Nagamatsu, Hirofumi
    Yoshikawa, Ayako
    Nakamura, Shintaro
    Souba, Junko
    Isobe, Atsushi
    Hagiwara, Hitomi
    Ikari, Yuji
    IJC HEART & VASCULATURE, 2021, 34
  • [29] Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention The SORT OUT VII Trial
    Jensen, Lisette Okkels
    Thayssen, Per
    Maeng, Michael
    Ravkilde, Jan
    Krusell, Lars Romer
    Raungaard, Bent
    Junker, Anders
    Terkelsen, Christian Juhl
    Veien, Karsten Tange
    Villadsen, Anton Boel
    Kaltoft, Anne
    Tilsted, Hans-Henrik
    Hansen, Knud Norregaard
    Aaroe, Jens
    Kristensen, Steen Dalby
    Hansen, Henrik Steen
    Jensen, Svend Eggert
    Madsen, Morten
    Botker, Hans Erik
    Berencsi, Klara
    Lassen, Jens Flensted
    Christiansen, Evald Hoj
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [30] Integrity of stent polymer layer after drug-eluting stent implantation: In vivo comparison of sirolimus-, paclitaxel-, zotarolimus- and everolimus-eluting stents
    Watanabe T.
    Fujita M.
    Awata M.
    Iida O.
    Okamoto S.
    Ishihara T.
    Uematsu M.