Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation

被引:46
|
作者
Koppara, Tobias [1 ]
Joner, Michael [1 ]
Bayer, Gerd [2 ]
Steigerwald, Kristin [1 ]
Diener, Tobias [2 ]
Wittchow, Eric [2 ]
机构
[1] Deutsch Herzzentrum Munich, D-80636 Munich, Germany
[2] BIOTRONIK SE & Co KG, Erlangen, Germany
关键词
Porcine model; sirolimus-eluting stents; restenosis; POOLED ANALYSIS; DURABLE POLYMER; CLINICAL-OUTCOMES; RELEASE PROFILES; COATED STENTS; FOLLOW-UP; IN-VITRO; DRUG; RESTENOSIS; TRIAL;
D O I
10.1160/TH12-01-0043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biodegradable stent coatings were recently introduced as a potential solution to overcome sustained inflammatory responses observed with permanent polymer-based drug-eluting stents. In a preliminary study, selected biodegradable or permanent polymer-based sirolimus-eluting stent (SES) formulations were screened for effectiveness in comparison to bare metal stents (BMS) at 28 days. Subsequently, the most favourable SES formulation was compared to commercially available SES (Cypher (TM)) at 28,90 and 180 days to investigate the histopathologic response as well as tissue, blood and organ pharmacokinetics. Overlapping SES implantation was conducted to evaluate vascular healing at 28 days in this particular setting. SES with biodegradable poly (L-lactide) polymer (PLLA) or poly(lactide-co-glycolide) showed the most favourable outcome with regards to reductions in neointimal area in comparison to BMS at 28 days. The PLLA SES showed a similar reduction in neointimal area compared to Cypher (TM) at 28 days, with significant greater reductions at 90 and 180 days (1.7 +/- 0.7 mm(2) vs. 3.1 +/- 1.5 mm(2), p=0.03 and 1.8 +/- 1.2 mm(2) vs. 3.0 +/- 1.5 mm(2), p=0.01, respectively). Sirolimus vascular tissue concentrations were detectable up to 90 days following implantation. Overlapping stented segments showed favourable histopathologic results with respect to fibrin deposition and endothelialisation at 28 days. In conclusion, the use of PLLA as drug-eluting matrix resulted in mild inflammatory responses in the presence of effective sirolimus tissue concentrations. The greater efficacy observed at long-term follow-up in PLLA SES compared to Cypher (TM) may be a multifactorial result of stent design, polymer biocompatibility and improved release kinetics.
引用
收藏
页码:1161 / 1171
页数:11
相关论文
共 50 条
  • [1] Randomised comparison of vascular response to biodegradable polymer sirolimus eluting and permanent polymer everolimus eluting stents: An optical coherence tomography study
    Koppara, Tobias
    Tada, Tomohisa
    Xhepa, Erion
    Kutner, Sebastian
    Byrne, Robert A.
    Ibrahim, Tareq
    Laugwitz, Karl -Ludwig
    Kastrati, Adnan
    Joner, Michael
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 258 : 42 - 49
  • [2] Quantitative assessment of late lumen loss after biodegradable polymer and permanent polymer sirolimus-eluting stents implantation
    Kan Jing
    Chen Feng
    Liu Li-ya
    Xu Hai-mei
    Lin Ling
    Liu Yan
    Zhao Ying-ying
    Cheng Jiu-pei
    Chen Shao-liang
    CHINESE MEDICAL JOURNAL, 2013, 126 (06) : 1081 - 1085
  • [3] Comparative preclinical evaluation of a polymer- free sirolimus-eluting stent in porcine coronary arteries
    Sperling, Christian
    Waliszewski, Matthias W.
    Kherad, Behrouz
    Krackhardt, Florian
    THERAPEUTIC ADVANCES IN CARDIOVASCULAR DISEASE, 2019, 13 : 1 - 13
  • [4] Safety and Efficacy of New Biodegradable Polymer-based Sirolimus-Eluting Stents in a Preclinical Model
    Perez de Prado, Armando
    Perez Martinez, Claudia
    Cuellas Ramon, Carlos
    Regueiro Purrinos, Marta
    Lopez Benito, Maria
    Gonzalo Orden, Jose Manuel
    Rodriguez Altonaga, Jose Antonio
    Estevez Loureiro, Rodrigo
    Benito Gonzalez, Tomas
    Vinuela Baragano, David
    Molina Crisol, Maria
    Amoros Aguilar, Marc
    Perez Serranos, Isabel
    Vidal Parreu, Arnau
    Benavides Montegordo, Ana
    Duocastella Codina, Luis
    Fernandez Vazquez, Felipe
    REVISTA ESPANOLA DE CARDIOLOGIA, 2017, 70 (12): : 1059 - 1066
  • [5] Stent Thrombosis with Biodegradable Polymer Drug-Eluting Stents versus Durable Polymer Sirolimus-Eluting Stents: An Update Meta-Analysis
    Zhu, Lin
    Lv, Yi Ning
    Wang, Li Yu
    CARDIOLOGY, 2015, 130 (02) : 96 - 105
  • [6] Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction
    Pilgrim, Thomas
    Piccolo, Raffaele
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Vuilliomenet, Andre
    Muller, Olivier
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Khattab, Ahmed A.
    Taniwaki, Masanori
    Rigamonti, Fabio
    Nietlispach, Fabian
    Blochlinger, Stefan
    Wenaweser, Peter
    Juni, Peter
    Windecker, Stephan
    EUROINTERVENTION, 2016, 12 (11) : E1343 - E1354
  • [7] Bioresorbable polymer sirolimus-eluting coronary stent compared with permanent polymer everolimus-eluting coronary stent implantation for treatment of small vessel coronary artery disease: CENTURY II trial
    Woehrle, Jochen
    Markovic, Sinisa
    Rottbauer, Wolfgang
    Muramatsu, Toshiya
    Kadota, Kazushige
    Vazquez-Gonzalez, Nicolas
    Odenstedt, Jacob
    Serra, Antonio
    Antoniucci, David
    Varenne, Olivier
    Saito, Shigeru
    Wijns, William
    EUROINTERVENTION, 2016, 12 (02) : E167 - E174
  • [8] Angiographic Outcomes With Biodegradable Polymer and Permanent Polymer Drug-Eluting Stents
    Kufner, Sebastian
    Massberg, Steffen
    Dommasch, Michael
    Byrne, Robert A.
    Tiroch, Klaus
    Ranftl, Sabine
    Fusaro, Massimiliano
    Schoemig, Albert
    Kastrati, Adnan
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 161 - 166
  • [9] Long-Term Effects of Novel Biodegradable, Polymer-Coated, Sirolimus-Eluting Stents on Neointimal Formation in a Porcine Coronary Model
    Peng, Hong-Yu
    Chen, Ming
    Zheng, Bo
    Wang, Xin-Gang
    Huo, Yong
    INTERNATIONAL HEART JOURNAL, 2009, 50 (06) : 811 - 822
  • [10] Safety and efficacy of cobalt chromium alloy based sirolimus-eluting stent with bioabsorbable polymer in porcine model
    Wu Yi-zhe
    Shen Li
    Wang Qi-bing
    Hu Xi
    Xie Jian
    Qian Ju-ying
    Ge Jun-bo
    CHINESE MEDICAL JOURNAL, 2012, 125 (06) : 983 - 989