A rapid and simple LC-MS/MS method for personalized busulfan dosing in pediatric patients undergoing hematopoietic stem cell transplantation (HSCT)

被引:7
|
作者
Xiao, Yi [1 ]
Li, Xiaohan [2 ]
Fu, Xiaowei [1 ,3 ]
机构
[1] Childrens Hosp Los Angeles, Dept Pathol & Lab Med, 4650 Sunset Blvd MS 32, Los Angeles, CA 90027 USA
[2] China Med Univ, Shengjing Hosp, Dept Pathol, Shenyang 110004, Liaoning, Peoples R China
[3] Univ Southern Calif, Keck Sch Med, Dept Pathol, Los Angeles, CA 90089 USA
关键词
Busulfan; High performance liquid chromatography-mass spectrometry; BONE-MARROW-TRANSPLANTATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; HEPATIC VENOOCCLUSIVE DISEASE; INTRAVENOUS BUSULFAN; HUMAN-PLASMA; DECREASED INCIDENCE; MASS-SPECTROMETRY; DOSE ADJUSTMENT; ORAL BUSULFAN; PHARMACOKINETICS;
D O I
10.1016/j.cca.2018.01.020
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Busulfan is commonly used as a conditioning regimen before hematopoietic stem cell transplantation (HSCT). There is a big inter-individual variability in busulfan exposure and the narrow therapeutic index, especially in pediatric population. Therefore, to achieve therapeutic efficacy and safety concurrently, personalized busulfan dosing, guided by pharmacokinetic study with serial plasma samples, is needed a few hours afterwards. Methods: A fast, sensitive, and accurate method for busulfan measurement was developed, validated, and implemented with liquid-chromatography-mass spectrometry (HPLC-MS/MS). The sample preparation procedure involves only protein precipitation and dilution, and the HPLC MS/MS method takes 3 min/sample. The assay was linear from 10 ng/ml to 7500 ng/ml (R-2 = 0.99). Recoveries were above 90%. The precision was determined at 3 levels (30, 300 and 4000 ng/ml): the intra-day variability (%CV) ranged from 1.4% to 2.5% (n = 20); the inter-day variability ranged from 2.2% to 5.5% (n = 20). The accuracy of the HPLC MS/MS test was evaluated with an old HPLC-fluorescence method (n = 84), and a Correlation Coefficient (R) of 0.99 was observed. Conclusions: The analytical performance of the assay allows for timely dose adjustment and has been implemented in clinical service for better clinical outcome.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [41] Development of a Simple and Rapid Method to Measure the Free Fraction of Tacrolimus in Plasma Using Ultrafiltration and LC-MS/MS
    Stienstra, Nicolaas A.
    Sikma, Maaike A.
    van Dapperen, Anouk L.
    de lange, Dylan W.
    van Maarseveen, Erik M.
    THERAPEUTIC DRUG MONITORING, 2016, 38 (06) : 722 - 727
  • [42] Population pharmacokinetics analysis of intravenous busulfan in Chinese patients undergoing hematopoietic stem cell transplantation
    Wu, Xuemei
    Xie, Helin
    Lin, Weiwei
    Yang, Ting
    Li, Nainong
    Lin, Shanshan
    Yuan, Xiaohong
    Ren, Jinhua
    Li, Xiaofan
    Huang, Xian
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2017, 44 (05): : 529 - 538
  • [43] Pediatric patients undergoing hematopoietic stem cell transplantation can greatly benefit from a novel once-daily intravenous busulfan dosing nomogram
    Rhee, Su-jin
    Lee, Ji Won
    Yu, Kyung-Sang
    Hong, Kyung Taek
    Choi, Jung Yoon
    Hong, Che Ry
    Park, Kyung Duk
    Shin, Hee Young
    Song, Sang Hoon
    Kang, Hyoung Jin
    Lee, Howard
    AMERICAN JOURNAL OF HEMATOLOGY, 2017, 92 (07) : 607 - 613
  • [44] Simple, sensitive and rapid LC-MS method for the quantitation of indapamide in human plasma - application to pharmacokinetic studies
    Chen, Wei-Dong
    Liang, Yan
    Zhang, Hong
    Li, Hao
    Xiong, Ye
    Wang, Guang-Ji
    Xie, Lin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (01): : 58 - 63
  • [45] Simple, sensitive, and rapid LC-MS method for the quantitation of indapamide in human plasma - Application to pharmacokinetic studies
    Liang, Yan
    Li, Hao
    Chen, Wei-Dong
    Liu, Xiao-Dong
    Wang, Guang-Ji
    Xie, Lin
    ANALYTICAL LETTERS, 2006, 39 (07) : 1365 - 1379
  • [46] Therapeutic monitoring of serum digoxin for patients with heart failure using a rapid LC-MS/MS method
    Li, Shuijun
    Liu, Gangyi
    Jia, Jingying
    Miao, Yi
    Gu, Shuiming
    Miao, Peizhi
    Shi, Xueying
    Wang, Yiping
    Yu, Chen
    CLINICAL BIOCHEMISTRY, 2010, 43 (03) : 307 - 313
  • [47] A simple and rapid LC-MS/MS method for the simultaneous determination of eight antipsychotics in human serum, and its application to therapeutic drug monitoring
    Cao, Yunfeng
    Zhao, Furong
    Chen, Jianxing
    Huang, Ting
    Zeng, Jia
    Wang, Lu
    Sun, Xiaoyu
    Miao, Yanming
    Wang, Shuang
    Chen, Chunwu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1147
  • [48] Development of simple and rapid LC-MS/MS method for determination of celecoxib in human plasma and its application to bioequivalence study
    Park, Mi-Sun
    Shim, Wang-Seob
    Yim, Sung-Vin
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 137 - 141
  • [49] A simple, rapid and sensitive HILIC LC-MS/MS method for simultaneous determination of 16 purine metabolites in plasma and urine
    Li, Xiaona
    Liu, Zhini
    Li, Zhuo
    Xiong, Xin
    Zhang, Xianhua
    Yang, Changqing
    Zhao, Libo
    Zhao, Rongsheng
    TALANTA, 2024, 267
  • [50] Development and validation of a sensitive and simple LC-MS/MS method for simultaneous quantitation of valsartan, sacubitril and sacubitrilat in pediatric population
    Yang, Quancheng
    Cao, Peng
    Lv, Yi
    Peng, Hua
    Zhai, Xuejia
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 238