Using a DFIG based wind turbine for grid current harmonics filtering

被引:31
|
作者
Kesraoui, M. [1 ]
Chaib, A. [1 ]
Meziane, A. [2 ]
Boulezaz, A. [2 ]
机构
[1] Univ MHamed Bougara, Lab Automat Appl, Boumerdes, Algeria
[2] Univ Mhamed Bougara, IGEE, Boumerdes, Algeria
关键词
DFIG; Wind power system; Power generation; Harmonics filtering; High selectivity filter; GENERATION; SYSTEM;
D O I
10.1016/j.enconman.2013.07.090
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper a variable speed doubly fed induction generator (DFIG) based wind energy conversion system (WECS) is employed for simultaneous power generation and grid harmonic current filtering. WECS active and reactive powers are controlled using vector control strategy. An improved harmonic isolator in the time domain, based on a new high selective signal detector or filter (HSF) has been used. Since the polluting currents contain direct and reverse harmonics of (6k +/- 1) order, the HSF can be used to isolate one particular harmonic or the whole harmonic components. The compensation technique of the whole harmonic components of the grid current is chosen. The rotor side converter (RSC) control structure has been modified in order to include the filtering task. Simulation for a 3 MW WECS with DFIG at two different wind speeds (8 m/s and 12 m/s) has been performed. Results showed that in addition to power generation, grid current harmonics filtering action is achieved by the WECS and a decrease by 4% of the total harmonic distortion is obtained. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:968 / 975
页数:8
相关论文
共 50 条
  • [41] Limiting the Fault Current of a DFIG Wind Turbine System Using Resistive Ladder Network
    Thapaliya, Sudeep
    Rahim, A. H. M. A.
    2022 INTERNATIONAL CONFERENCE ON ENERGY AND POWER ENGINEERING, ICEPE, 2022,
  • [42] An integral backstepping algorithm for a DFIG-based wind turbine connected to the undisturbed utility grid
    Boulaoutaq, El Mahfoud
    Kourchi, Mustapha
    Rachdy, Azeddine
    Test Engineering and Management, 2019, 81 (11-12): : 4446 - 4460
  • [43] Control strategy of an active crowbar for DFIG based wind turbine under grid voltage dips
    Peng, Zhou
    He Yikang
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1489 - 1494
  • [44] A DFIG-based Wind Turbine Operation under Balanced and Unbalanced Grid Voltage Conditions
    Boukili, Yassine
    Aguiar, A. Pedro
    Carvalho, Adriano
    IFAC PAPERSONLINE, 2020, 53 (02): : 12835 - 12840
  • [45] Mitigation of Torsional Vibrations in the Drivetrain of DFIG-based Grid-Connected Wind Turbine
    Fateh, Fariba
    White, Warren N.
    Gruenbacher, Don
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4159 - 4164
  • [46] Control and Protection of a DFIG-Based Wind Turbine under Unbalanced Grid Voltage Dips
    Zhou, Peng
    He, Yikang
    Sun, Dan
    Zhu, Jianguo
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 2375 - +
  • [47] Fault Diagnosis of Wind Turbine Gearboxes Based on DFIG Stator Current Envelope Analysis
    Cheng, Fangzhou
    Qu, Liyan
    Qiao, Wei
    Wei, Chun
    Hao, Liwei
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2019, 10 (03) : 1044 - 1053
  • [48] Fault Management in DFIG Based Wind Turbine Using Sophisticated Advanced solid State Fault Current Limiter
    Shobug, Md Asaduzzaman
    Sheikh, M. R., I
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1660 - 1663
  • [49] Improved Control of Grid-connected DFIG-based Wind Turbine using Proportional-Resonant Regulators during Unbalanced Grid
    El Karkri, Yassir
    Rey-Boue, Alexis B.
    El Moussaoui, Hassan
    Stoeckl, Johannes
    Strasser, Thomas, I
    ENERGIES, 2019, 12 (21)
  • [50] A robust direct current control of DFIG wind turbine with low current THD based predictive approach
    Zarei, Mohammad Ebrahim
    Asaei, Behzad
    WIND ENERGY, 2016, 19 (07) : 1181 - 1199