Total Petroleum Hydrocarbon Concentration Prediction in Soils Using Diffuse Reflectance Infrared Spectroscopy

被引:47
|
作者
Forrester, Sean T. [1 ]
Janik, Les J. [1 ]
McLaughlin, Michael J. [1 ,2 ]
Soriano-Disla, Jose M. [1 ,3 ]
Stewart, Richard [4 ]
Dearman, Ben
机构
[1] CSIRO Land & Water, CSIRO Water Healthy Country Flagship Program, Urrbrae, SA 5064, Australia
[2] Univ Adelaide, Glen Osmond, SA 5064, Australia
[3] Univ Miguel Hernandez Elche, Dep Agrochemistry & Environm, Elche 03202, Spain
[4] Ziltek Pty Ltd, Kent, SA 5071, Australia
关键词
PARTIAL LEAST-SQUARES; REGRESSION; DIESEL;
D O I
10.2136/sssaj2012.0201
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Partial least squares (PLS) calibration models, from diffuse reflectance infrared Fourier-transform (DRIFT) spectra, were developed for the prediction of total petroleum hydrocarbon (TPH) concentrations in contaminated soils. Soils were collected from sites in southeastern Australia known to be contaminated with TPH. Regression models were derived for concentration ranges of 0 to 32,600, 0 to 5000, 0 to 15,000, and 15,000 to 32,600 mg kg(-1). For each range, PLS models using selected near-infrared (NIR) and mid-infrared (MIR) frequencies were tested. The aliphatic alkyl stretching vibration regions were the most sensitive to TPH: NIR frequencies at 4500 to 4100 cm(-1) and MIR at 3000 to 4600 cm(-1). The MIR range included two -CH3 peaks, one at 2950 cm(-1) and the other near 2730 cm(-1), having strong correlation with TPH at low and high TPH concentrations, respectively. These peaks were considered to be either weak or absent in natural soil organic matter relative to the usual -CH2 region at 2930 to 2850 cm(-1). The PLS regression analysis using the combined 2980 to 2950 and 2777 to 2650 cm(-1) MIR frequency regions for the 0 to 15,000 mg kg(-1) set resulted in a ratio of prediction deviation of 3.7 ("analytical quality"), coefficient of determination (R-2) = 0.93, and root mean square error of cross-validation of 564 mg kg(-1). Using these MIR frequencies, the DRIFT infrared technique showed the potential to be a rapid and accurate nondestructive method to determine TPH concentrations in contaminated soils, potentially adaptable to in-field use.
引用
收藏
页码:450 / 460
页数:11
相关论文
共 50 条
  • [21] Assessing spatial variability of soil petroleum contamination using visible near-infrared diffuse reflectance spectroscopy
    Chakraborty, Somsubhra
    Weindorf, David C.
    Zhu, Yuanda
    Li, Bin
    Morgan, Cristine L. S.
    Ge, Yufeng
    Galbraith, John
    JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (11): : 2886 - 2892
  • [22] INFRARED SPECTROSCOPY OF METEORITES USING ATTENUATED TOTAL REFLECTANCE
    Reach, W. T.
    Rossman, G. R.
    METEORITICS & PLANETARY SCIENCE, 2010, 45 : A169 - A169
  • [23] Organic matter prediction for Korean soils using visible-near infrared reflectance spectroscopy
    Chun, H. C.
    Hong, S. Y.
    Song, K. C.
    Kim, Y. H.
    Hyun, B. K.
    Minasny, B.
    DIGITAL SOIL ASSESSMENTS AND BEYOND, 2012, : 377 - 380
  • [24] Prediction of lead concentration in soil using reflectance spectroscopy
    Al Maliki, Ali
    Bruce, David
    Owens, Gary
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2014, 1-2 : 8 - 15
  • [25] Specular reflection and diffuse reflectance spectroscopy of soils
    Reeves, JB
    Francis, BA
    Hamilton, SK
    APPLIED SPECTROSCOPY, 2005, 59 (01) : 39 - 46
  • [26] The use of diffuse reflectance mid-infrared spectroscopy for the prediction of the concentration of chemical elements estimated by X-ray fluorescence in agricultural and grazing European soils
    Soriano-Disla, J. M.
    Janik, L.
    McLaughlin, M. J.
    Forrester, S.
    Kirby, J.
    Reimann, C.
    APPLIED GEOCHEMISTRY, 2013, 29 : 135 - 143
  • [27] GEMAS: PREDICTION OF SOLID-SOLUTION PARTITIONING COEFFICIENTS (Kd) FOR CATIONIC METALS IN SOILS USING MID-INFRARED DIFFUSE REFLECTANCE SPECTROSCOPY
    Janik, Leslie J.
    Forrester, Sean T.
    Soriano-Disla, Jose M.
    Kirby, Jason K.
    McLaughlin, Michael J.
    Reimann, Clemens
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2015, 34 (02) : 224 - 234
  • [28] Rapid measurement of zinc contents in soils by near-infrared diffuse reflectance spectroscopy
    Huang, Fu-Rong
    Pan, Tao
    Zhang, Gan-Lin
    Pan, Xian-Zhang
    Liu, Deng-Fei
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (03): : 586 - 592
  • [29] Prediction of tablets disintegration times using near-infrared diffuse reflectance spectroscopy as a nondestructive method
    Donoso, M
    Ghaly, ES
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2005, 10 (02) : 211 - 217
  • [30] Prediction of tablet hardness and porosity using near-infrared diffuse reflectance spectroscopy as a nondestructive method
    Donoso, M
    Kildsig, DO
    Ghaly, ES
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2003, 8 (04) : 357 - 366