In matrix derivatization of trichloroethylene metabolites in human plasma with methyl chloroformate and their determination by solid-phase microextraction-gas chromatography-electron capture detector

被引:15
作者
Mudiam, Mohana Krishna Reddy [1 ]
Jain, Rajeev [1 ,2 ]
Varshney, Meenu [3 ]
Ch, Ratnasekhar [1 ]
Chauhan, Abhishek [1 ]
Goyal, Sudhir Kumar [3 ]
Khan, Haider A. [2 ]
Murthy, R. C. [1 ]
机构
[1] CSIR Indian Inst Toxicol Res, Analyt Chem Sect, Lucknow 226001, UP, India
[2] Jamia Hamdard, Dept Med Elementol & Toxicol, New Delhi 110006, India
[3] CSIR Indian Inst Toxicol Res, Lucknow 226001, UP, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2013年 / 925卷
关键词
TCE metabolites; Methyl chloroformate derivatization; SPME; Central composite design; GC-ECD; MASS-SPECTROMETRY; TRICHLOROACETIC-ACID; CHLORAL HYDRATE; URINE; WATER; OPTIMIZATION; SAMPLES; BLOOD;
D O I
10.1016/j.jchromb.2013.02.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Trichloroethylene (ICE) is a common industrial chemical that has been widely used as metal degreaser and for many industrial purposes. In humans, TCE is metabolized into dichloroacetic acid (DCA), trichloroacetic acid (TCA) and trichloroethanol (TCOH). A simple and rapid method has been developed for the quantitative determination of TCE metabolites. The procedure involves the in situ derivatization of TCE metabolites with methyl chloroformate (MCF) directly in diluted plasma samples followed by extraction and analysis with solid-phase microextraction (SPME) coupled to gas chromatography-electron capture detector (GC-ECD). Factors which can influence the efficiency of derivatization such as amount of MCF and pyridine (PYR), ratio of water/methanol were optimized. The factors which can affect the extraction efficiencies of SPME were screened using 2(7-4) Placket-Burman Design (PBD). A central composite design (CCD) was then applied to further optimize the most significant factors for optimum SPME extraction. The optimum factors for the SPME extraction were found to be 562.5 mg of NaCl, pH at 1 and an extraction time of 22 min. Recoveries and detection limits of all three analytes in plasma were found to be in the range of 92.69-97.55% and 0.036-0.068 mu g mL(-1) of plasma, respectively. The correlation coefficients were found to be in the range of 0.990-0.995. The intra- and inter-day precisions for TCE metabolites were found to be in the range of 2.37-4.81% and 5.13-7.61%, respectively. The major advantage of this method is that MCF derivatization allows conversion of TCE metabolites into their methyl esters in very short time (<= 30s) at room temperature directly in the plasma samples, thus makes it a solventless analysis. The method developed was successfully applied to the plasma samples of humans exposed to TCE. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 26 条
[1]   Simultaneous determination of aliphatic and aromatic amines in water and sediment samples by ion-pair extraction and gas chromatography-mass spectrometry [J].
Akyuz, Mehmet ;
Atu, Sevket .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1129 (01) :88-94
[2]  
Amy D.D., 2005, BIOMED CHROMATOGR, V19, P617
[3]  
[Anonymous], 1998, FITN PURP AN METH LA
[4]  
Aurthur C.L., 1990, ANAL CHEM, V62, P2145
[5]   Response surface methodology (RSM) as a tool for optimization in analytical chemistry [J].
Bezerra, Marcos Almeida ;
Santelli, Ricardo Erthal ;
Oliveira, Eliane Padua ;
Villar, Leonardo Silveira ;
Escaleira, Luciane Amlia .
TALANTA, 2008, 76 (05) :965-977
[6]   ON THE EXPERIMENTAL ATTAINMENT OF OPTIMUM CONDITIONS [J].
BOX, GEP ;
WILSON, KB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1951, 13 (01) :1-45
[7]  
Citova I., 2006, ANAL CHIM ACTA, V231, P573
[8]   DETERMINATION OF CHLORAL HYDRATE, TRICHLOROACETIC ACID, AND TRICHLOROETHANOL [J].
FRIEDMAN, PJ ;
COOPER, JR .
ANALYTICAL CHEMISTRY, 1958, 30 (10) :1674-1676
[9]   Chloroformates in gas chromatography as general purpose derivatizing agents [J].
Husek, P .
JOURNAL OF CHROMATOGRAPHY B, 1998, 717 (1-2) :57-91
[10]   DETERMINATION OF 2,2,2-TRICHLOROETHANOL IN PLASMA AND URINE BY ION-EXCLUSION CHROMATOGRAPHY [J].
ITOH, H ;
IKEDA, S ;
ICHINOSE, N .
ANALYST, 1994, 119 (03) :409-413