The Limit of the Lateral Fundamental Frequency and Comfort Analysis of a Straddle-Type Monorail Tour Transit System

被引:5
作者
Guo, Fengqi [1 ]
Ji, Yanqiang [1 ]
Liao, Qiaoyun [2 ]
Liu, Bo [2 ]
Li, Chenjia [1 ]
Wei, Shiqi [1 ]
Xiang, Ping [1 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha 410075, Peoples R China
[2] Zhuzhou CRRC Special Equipment Technol Co Ltd, Zhuzhou 412004, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 20期
关键词
straddle-type monorail tour transit system; lateral vibration; human-induced vibration; comfort level; VERTICAL BENDING VIBRATION; RAILWAY; SUPPRESSION; REDUCTION; BODY;
D O I
10.3390/app122010434
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The straddle-type monorail tour transit system is a light overhead steel structure, and the lateral stiffness is generally low. However, the limit of the lateral natural vibration frequency is not clear in the current codes of China, and designers may ignore it. Weak lateral stiffness will lead to a violent vibration during vehicle operation and crowds walking, affecting human comfort and structural safety. Based on a practical project, we tested the acceleration of a monorail vehicle under full load conditions, and its running stability and ride comfort were assessed. Then, the impact of pedestrians on lateral vibration under some working conditions was measured and analyzed. Furthermore, the influence of different structural parameters on the lateral fundamental frequency was investigated. The results showed the following: (i) The vehicle's running stability and riding comfort was good. However, human comfort was poor due to the weak lateral stiffness of the structure, which was affected by human-induced vibration. (ii) The comprehensive response of the structure increased with the increase in walking frequency, increased with the increase in the number of people working or weight, and the growth speed slowed down. (iii) The structural stiffness was most sensitive to the change in steel column diameter. (iv) The recommended value of the lateral fundamental frequency limit for different spans of the straddle-type monorail tour transit system was put forward. The recommended lower limit of fundamental frequency for a 15 m span is 5.0 Hz, for an 18 m span it is 3.5 Hz, and for a 25 m span it is 2.8 Hz.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Aida K.Y., 2015, Q REP RTRI, V56, P262, DOI [10.2219/rtriqr.56.4_262, DOI 10.2219/RTRIQR.56.4_262]
  • [2] [Anonymous], 2017, 512342017 GBT
  • [3] [Anonymous], 2019, ACM Trans. Intell. Syst. Technol., DOI DOI 10.1145/3298981
  • [4] Cao L, 2010, CHINA CIVIL ENG J, VS1, P334
  • [5] Running Safety and Comfort Analysis of Railway Vehicles Moving on Curved Tracks
    Cheng, Yung-Chang
    Hsu, Chin-Te
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2014, 14 (04)
  • [6] Dumitriu Madalina, 2019, Materials Science Forum, V957, P53, DOI 10.4028/www.scientific.net/MSF.957.53
  • [7] Vertical bending vibration analysis of the car body of railway vehicle
    Dumitriu, M.
    Stanica, D. I.
    [J]. INNOVATIVE MANUFACTURING ENGINEERING AND ENERGY (IMANEE 2019) - 50 YEARS OF HIGHER TECHNICAL EDUCATION AT THE UNIVERSITY OF PITESTI, 2019, 564
  • [8] Dumitriu Madalina, 2018, Applied Mechanics and Materials, V880, P207, DOI 10.4028/www.scientific.net/AMM.880.207
  • [9] Ride comfort enhancement in railway vehicle by the reduction of the car body structural flexural vibration
    Dumitriu, M.
    [J]. MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING V, 2017, 227
  • [10] Dumitriu M., 2020, UPB SCI B D, V82, P81