MONTE CARLO-BASED INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTION OF HIGH ENERGY BRACHYTHERAPY SOURCES

被引:9
|
作者
Chattaraj, Arghya [1 ,2 ]
Selvam, T. Palani [1 ,2 ]
Datta, D. [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Safety & Environm Grp, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, Maharashtra, India
关键词
RELATIVE BIOLOGICAL EFFECTIVENESS; SINGLE EVENT SPECTRA; CO-60; GAMMA-RAYS; WALL-LESS; X-RAYS; I-125; PD-103; SIMULATION; PARAMETERS; PHOTONS;
D O I
10.1093/rpd/ncz148
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
FLUKA-based Monte Carlo calculations were carried out to study microdosimetric distributions in air and in water for encapsulated high energy brachytherapy sources (Co-60, Cs-137, Ir-192 and Yb-169) by simulating a Tissue Equivalent Proportional Counter (Model LET1/2) having sensitive diameter of 1. 27 cm for a site size of 1 mu m. The study also included microdosimetric distributions of bare sources. When the sources are in air, for a given source, the source geometry does not affect the (y) over bar (F) and (y) over bar (D) values significantly. When the encapsulated Ir-192, Cs-137 and Co-60 sources are in water, (y) over bar (F) and (y) over bar (D) values increase with distance in water which is due to degradation in the energy of photons. Using the calculated values of (y) over bar, relative biological effectiveness (RBE) was obtained for the investigated sources. When Co-60, Cs-137 and Ir-192 sources are in water, RBE increases from 1.03 +/- 0.01 to 1.17 +/- 0.01, 1.24 +/- 0.01 to 1.46 +/- 0.02 and 1.50 +/- 0.01 to 1.75 +/- 0.03, respectively, when the distance was increased from 3-15 cm, whereas for Yb-169, RBE is about 2, independent of distance in water.
引用
收藏
页码:115 / 128
页数:14
相关论文
共 50 条
  • [1] FLUKA-BASED MONTE CARLO INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTIONS OF TELECOBALT BEAM
    Selvam, T. Palani
    Chattaraj, Arghya
    Datta, D.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (04) : 430 - 440
  • [2] Intratumoral Injection of Low-Energy Photon-Emitting Gold Nanoparticles: A Microdosimetric Monte Carlo-Based Model
    Laprise-Pelletier, Myriam
    Ma, Yunzhi
    Lagueux, Jean
    Cote, Marie-France
    Beaulieu, Luc
    Fortin, Marc-Andre
    ACS NANO, 2018, 12 (03) : 2482 - 2497
  • [3] A Monte Carlo-based dosimetric characterization of Esteya®, an electronic surface brachytherapy unit
    Valdes-Cortez, Christian
    Niatsetski, Yury
    Perez-Calatayud, Jose
    Ballester, Facundo
    Vijande, Javier
    MEDICAL PHYSICS, 2019, 46 (01) : 356 - 369
  • [4] A comparison of the relative biological effectiveness of low energy electronic brachytherapy sources in breast tissue: a Monte Carlo study
    White, Shane A.
    Reniers, Brigitte
    de Jong, Evelyn E. C.
    Rusch, Thomas
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) : 383 - 399
  • [5] A new Monte Carlo-based fitting method
    Pedroni, P.
    Sconfietti, S.
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2020, 47 (05)
  • [6] Monte Carlo-Based Radiobiological Investigation of the Most Optimal Ion Beam Forming SOBP for Particle Therapy
    Kantemiris, Ioannis
    Pappas, Eleftherios P. P.
    Lymperopoulou, Georgia
    Thanasas, Dimitrios
    Karaiskos, Pantelis
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (01):
  • [7] Automation of Monte Carlo-based treatment plan verification for proton therapy
    Kaluarachchi, Maduka
    Moskvin, Vadim
    Pirlepesov, Fakhriddin
    Wilson, Lydia J.
    Xie, Fang
    Faught, Austin M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (08): : 131 - 138
  • [8] Monte Carlo-based sensitivity analysis of an electrochemical capacitor
    Kannan, Vishvak
    Somasundaram, Karthik
    Fisher, Adrian
    Birgersson, Erik
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (11) : 16947 - 16962
  • [9] The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources
    Landry, Guillaume
    Reniers, Brigitte
    Pignol, Jean-Philippe
    Beaulieu, Luc
    Verhaegen, Frank
    MEDICAL PHYSICS, 2011, 38 (03) : 1526 - 1533
  • [10] A parallel approach for Monte Carlo-based photon propagation simulation
    Rusu, Ionela
    Pentiuc, Stefan-Gheorghe
    Ungurean, Ioan
    Craciun, Elena-Gina
    2012 5TH ROMANIA TIER 2 FEDERATION GRID, CLOUD & HIGH PERFORMANCE COMPUTING SCIENCE (RO-LCG), 2012, : 78 - 81