Food analysis on microchip electrophoresis: An updated review

被引:49
作者
Martin, Aida [1 ]
Vilela, Diana [1 ]
Escarpa, Alberto [1 ]
机构
[1] Univ Alcala, Dept Analyt Chem & Chem Engn, E-28871 Madrid, Spain
关键词
Electrochemical detection; Food analysis; Microchip electrophoresis; Optical detection; FIELD-STRENGTH GRADIENTS; GENETICALLY-MODIFIED ORGANISMS; CAPILLARY-ELECTROPHORESIS; GEL-ELECTROPHORESIS; CHIP; SEPARATION; IDENTIFICATION; ELECTRODE; SYSTEMS; NITRITE;
D O I
10.1002/elps.201200049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
From 2008 to date, basically, single-cross microchip electrophoresis (ME) design has been used for food analysis with electrochemicaland laser-induced fluorescencedetection being the most commonprinciples coupled. In the last 4 years, the main outlines were: (i) the exploration of new analytes such as heavy metals, nitrite, micotoxins, microorganisms, and allergens; (ii) the development of electrokinetic microfluidic (bio-) sensors into microchip format for the detection of toxins; and interestingly (iii) although sample preparation is still performed off-chip, an important increase in works dealing with complicated food samples has been clearly noticed. Although microchip technology based on electrokinetics is emerging from important fields such as authentication of foods, detection of frauds, toxics, and allergens; the marriage between micro- and nanotechnologies and total integration approaches has not reached the expected impact in the field but it is still a great promise for the development of ME of new generations for food analysis.
引用
收藏
页码:2212 / 2227
页数:16
相关论文
共 42 条
[1]   Microfluidic analytical systems for food analysis [J].
Atalay, Yegermal T. ;
Vermeir, Steven ;
Witters, Daan ;
Vergauwe, Nicolas ;
Verbruggen, Bert ;
Verboven, Pieter ;
Nicolai, Bart M. ;
Lammertyn, Jeroen .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2011, 22 (07) :386-404
[2]   Modeling and optimization of a multi-enzyme electrokinetically driven multiplexed microchip for simultaneous detection of sugars [J].
Atalay, Yegermal Tesfaw ;
Verboven, Pieter ;
Vermeir, Steven ;
Vergauwe, Nicolas ;
Nicolai, Bart ;
Lammertyn, Jeroen .
MICROFLUIDICS AND NANOFLUIDICS, 2009, 7 (03) :393-406
[3]   Fast single run of vanilla fingerprint markers on microfluidic-electrochemistry chip for confirmation of common frauds [J].
Avila, Monica ;
Zougagh, Mohammed ;
Escarpa, Alberto ;
Rios, Angel .
ELECTROPHORESIS, 2009, 30 (19) :3413-3418
[4]  
Blasco A., 2005, ELECTROCHEMICAL DETE
[5]   Fast and simultaneous detection of prominent natural antioxidants using analytical microsystems for capillary electrophoresis with a glassy carbon electrode:: A new gateway to food environments [J].
Blasco, AJ ;
Barrigas, I ;
González, MC ;
Escarpa, A .
ELECTROPHORESIS, 2005, 26 (24) :4664-4673
[6]   Fast and simultaneous detection of heavy metals using a simple and reliable microchip-electrochemistry route: An alternative approach to food analysis [J].
Chailapakul, Orawon ;
Korsrisakul, Sarawadee ;
Siangproh, Weena ;
Grudpan, Kate .
TALANTA, 2008, 74 (04) :683-689
[7]   Fast Analysis of Phenolic Acids by Microchip Capillary Electrophoresis with Serpentine Channel and End Wrapped Electrode [J].
Cheng, Hsien-Yu ;
Chen, Show-Chuen ;
Lee, Hui-Ling .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (3A) :371-377
[8]   Microchip capillary electrophoresis (Lab-on-chip®) improves detection of celery (Apium graveolens L.) and sesame (Sesamum indicum L.) in foods [J].
Coisson, J. D. ;
Cereti, E. ;
Garino, C. ;
D'Andrea, M. ;
Recupero, M. ;
Restani, P. ;
Arlorio, M. .
FOOD RESEARCH INTERNATIONAL, 2010, 43 (05) :1237-1243
[9]   Food analysis on microfluidic devices using ultrasensitive carbon nanotubes detectors [J].
Crevillen, A. Gonzalez ;
Avila, Monica ;
Pumera, Martin ;
Gonzalez, Maria Cristina ;
Escarpa, Alberto .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7408-7415
[10]   The preferential electrocatalytic behaviour of graphite and multiwalled carbon nanotubes on enediol groups and their analytical implications in real domains [J].
Crevillen, Agustin G. ;
Pumera, Martin ;
Gonzalez, M. Cristina ;
Escarpa, Alberto .
ANALYST, 2009, 134 (04) :657-662