Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter

被引:63
作者
Anter, Elad [1 ]
Tschabrunn, Cory M. [1 ]
Contreras-Valdes, Fernando M. [1 ]
Li, Jianqing [1 ]
Josephson, Mark E. [1 ]
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Cardiovasc Div,Dept Med,Harvard Thorndike Electro, Boston, MA 02215 USA
关键词
Atrial fibrillation; Pulmonary vein isolation; Rhythmia; Orion; Lasso; Basket catheter; PAROXYSMAL ATRIAL-FIBRILLATION; ABLATION;
D O I
10.1016/j.hrthm.2015.05.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVT. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. OBJECTIVE The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. METHODS In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. RESULTS At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. CONCLUSION The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation.
引用
收藏
页码:1927 / 1934
页数:8
相关论文
共 6 条
[1]   Acute pulmonary vein reconnection is a predictor of atrial fibrillation recurrence following pulmonary vein isolation [J].
Anter, Elad ;
Contreras-Valdes, Fernando M. ;
Shvilkin, Alexei ;
Tschabrunn, Cory M. ;
Josephson, Mark E. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (03) :225-232
[2]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[3]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[4]   Rapid High Resolution Electroanatomical Mapping Evaluation of a New System in a Canine Atrial Linear Lesion Model [J].
Nakagawa, Hiroshi ;
Ikeda, Atsushi ;
Sharma, Tushar ;
Lazzara, Ralph ;
Jackman, Warren M. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (02) :417-424
[5]   Complete isolation of left atrium surrounding the pulmonary veins -: New insights from the double-lasso technique in paroxysmal atrial fibrillation [J].
Ouyang, FF ;
Bänsch, D ;
Ernst, S ;
Schaumann, A ;
Hachiya, H ;
Chen, ML ;
Chun, JL ;
Falk, P ;
Khanedani, A ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 110 (15) :2090-2096
[6]   Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: Verification of intracardiac signals with a second circular mapping catheter [J].
Rosso, Raphael ;
Halkin, Amir ;
Michowitz, Yoav ;
Belhassen, Bernard ;
Glick, Aharon ;
Viskin, Sami .
HEART RHYTHM, 2014, 11 (04) :559-565