Simulation of energy saving potential of a centralized HVAC system in an academic building using adaptive cooling technique

被引:26
作者
Bhaskoro, Petrus Tri [1 ]
Gilani, Syed Ihtsham Ul Haq [1 ]
Aris, Mohd Shiraz [1 ]
机构
[1] Univ Teknol PETRONAS, Dept Mech Engn, Kuala Lumpur, Malaysia
关键词
Transient cooling load characteristic; HVAC system; Adaptive cooling technique; Energy saving potentials; Academic building; THERMAL COMFORT; RESIDENTIAL BUILDINGS; MODEL; LOAD; CONSERVATION; ENVIRONMENT; EFFICIENCY; STANDARDS; CLIMATES;
D O I
10.1016/j.enconman.2013.06.054
中图分类号
O414.1 [热力学];
学科分类号
摘要
Application of adaptive comfort temperature as room temperature set points potentially reduce energy usage of the HVAC system during a cooling and heating period. The savings are mainly due to higher indoor temperature set point during hot period and lower indoor temperature set point during cold period than the recommended value. Numerous works have been carried out to show how much energy can be saved during cooling and heating period by applying adaptive comfort temperature. The previous work, however, focused on a continuous cooling load as found in many office and residential buildings. Therefore, this paper aims to simulate the energy saving potential for an academic glazed building in tropical Malaysian climate by developing adaptive cooling technique. A building simulation program (TRNSYS) was used to model the building and simulate the cooling load characteristic using current and proposed technique. Two experimental measurements were conducted and the results were used to validate the model. Finally, cooling load characteristic of the academic building using current and proposed technique were compared and the results showed that annual energy saving potential as much as 305,150 kW h can be achieved. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 628
页数:12
相关论文
共 39 条
[1]  
Al Riza DF., 2010, EFEEA 10 INT S ENV F
[2]  
[Anonymous], CONSTR DRAW
[3]  
[Anonymous], AIR COND VENT DRAW
[4]  
[Anonymous], MAT SPEC
[5]  
[Anonymous], 2005, VENT ACC IND AIR QUA
[6]   Simulation of a VAV air conditioning system in an existing building for the cooling mode [J].
Aynur, Tolga N. ;
Hwang, Yunho ;
Radermacher, Reinhard .
ENERGY AND BUILDINGS, 2009, 41 (09) :922-929
[7]  
Bhaskoro P. T., 2010, ICPER KUAL LUMP MAL
[8]   Investigation of some large building energy conservation opportunities using the DOE-2 model [J].
Carriere, M ;
Schoenau, GJ ;
Besant, RW .
ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (08) :861-872
[9]  
Cengel YA, 2008, Thermodynamics: an engineering approach 6th editon (SI units)
[10]  
Crawley DB, 2005, 9 INT IBPSA C BUILD