Split-Dose Bowel Preparation Reduces the Need for Early Repeat Colonoscopy Without Improving Adenoma Detection Rate

被引:4
作者
Wang, Li [1 ]
Sprung, Brandon S. [2 ]
DeCross, Arthur J. [2 ]
Marino, Danielle [2 ]
机构
[1] Univ Massachusetts, Dept Med, Internal Med Residency Program, 55 North Lake Ave, Worcester, MA 01655 USA
[2] Univ Rochester, Med Ctr, Div Gastroenterol & Hepatol, 601 Elmwood Ave,Box 646, Rochester, NY 14642 USA
关键词
Adenoma detection rate; Boston Bowel Preparation Scale; Early repeat colonoscopy; High baseline ADR; RANDOMIZED CONTROLLED-TRIAL; COLORECTAL-CANCER; POLYETHYLENE-GLYCOL; WATER EXCHANGE; SCREENING COLONOSCOPY; QUALITY INDICATORS; RISK; MULTICENTER; METAANALYSIS; INTERVAL;
D O I
10.1007/s10620-017-4877-3
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Split-dose bowel preparation is associated with improved mucosal visualization and patient tolerance, becoming a standard of care. However, quality measures data associated with this preparation are limited. At our academic tertiary-care facility, we aim to study the effect of changing from single- to split-dose preparation on colonoscopy quality measures. A retrospective cohort study with quality indicators was conducted using electronic medical record data. Cases were identified via ICD9 code V76.51, "Special screening for malignant neoplasms of colon." Single-dose preparation data was collected from 9/1/13 to 8/31/14. Split-dose preparation was implemented 11/2014, and data were collected from 1/1/15 to 8/31/15. A total of 1602 colonoscopies in the single-dose group and 1061 colonoscopies in the split-dose group were analyzed. The Boston Bowel Preparation Scale was significantly improved in the split-dose group 8.64 +/- SD 1.25 versus 8.25 +/- SD 1.61, p < 0.001. There was no significant difference in adenoma detection rate 40.7% (95% CI 37.8-43.7%) versus 40.5% (95% CI 38.1-42.9%), p = 0.92; however, the rate for recommending an early repeat examination due to an inadequate bowel preparation was significantly decreased to 3.9% (95% CI 2.7-5.0%) versus 8.9% (95% CI 1.52-2.97%), p < 0.001. While split-dose preparation significantly improves overall bowel cleanliness, there is no significant adenoma detection rate improvement with high baseline rate, suggesting a threshold which may not improve with enhanced preparations. Split-dose preparation significantly reduces the frequency with which inadequate preparation prompts an early repeat examination, which has important clinical implications on performance, costs, and patient experience, providing further evidence supporting split-dose preparation use.
引用
收藏
页码:1320 / 1326
页数:7
相关论文
共 28 条
  • [1] [Anonymous], 2015, Gastrointest Endoscopy, V81, P31
  • [2] Colonoscopic withdrawal times and adenoma detection during screening colonoscopy
    Barclay, Robert L.
    Vicari, Joseph J.
    Doughty, Andrea S.
    Johanson, John F.
    Greenlaw, Roger L.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (24) : 2533 - 2541
  • [3] Association of Colonoscopy and Death From Colorectal Cancer
    Baxter, Nancy N.
    Goldwasser, Meredith A.
    Paszat, Lawrence F.
    Saskin, Refik
    Urbach, David R.
    Rabeneck, Linda
    [J]. ANNALS OF INTERNAL MEDICINE, 2009, 150 (01) : 1 - W1
  • [4] Protection From Right- and Left-Sided Colorectal Neoplasms After Colonoscopy: Population-Based Study
    Brenner, Hermann
    Hoffmeister, Michael
    Arndt, Volker
    Stegmaier, Christa
    Altenhofen, Lutz
    Haug, Ulrike
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2010, 102 (02) : 89 - 95
  • [5] Water exchange for screening colonoscopy increases adenoma detection rate: a multicenter, double-blinded, randomized controlled trial
    Cadoni, Sergio
    Falt, Premysl
    Rondonotti, Emanuele
    Radaelli, Franco
    Fojtik, Petr
    Gallittu, Paolo
    Liggi, Mauro
    Amato, Arnaldo
    Paggi, Silvia
    Smajstrla, Vit
    Urban, Ondrej
    Erriu, Matteo
    Koo, Malcolm
    Leung, Felix W.
    [J]. ENDOSCOPY, 2017, 49 (05) : 456 - 467
  • [6] Cohen Benjamin, 2012, J Interv Gastroenterol, V2, P177
  • [7] Dawwas MF, 2014, NEW ENGL J MED, V370, P2539, DOI [10.1056/NEJMc1405329, 10.1056/NEJMoa1309086]
  • [8] 4-Liter Split-Dose Polyethylene Glycol Is Superior to Other Bowel Preparations, Based on Systematic Review and Meta-analysis
    Enestvedt, Brintha K.
    Tofani, Christina
    Laine, Loren A.
    Tierney, Ann
    Fennerty, M. Brian
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2012, 10 (11) : 1225 - 1231
  • [9] Increased adenoma detection rate with system-wide implementation of a split-dose preparation for colonoscopy
    Gurudu, Suryakanth R.
    Ramirez, Francisco C.
    Harrison, M. Edwyn
    Leighton, Jonathan A.
    Crowell, Michael D.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2012, 76 (03) : 603 - +
  • [10] Prospective multicenter randomized controlled trial comparing adenoma detection rate in colonoscopy using water exchange, water immersion, and air insufflation
    Hsieh, Yu-Hsi
    Tseng, Chih-Wei
    Hu, Chi-Tan
    Koo, Malcolm
    Leung, Felix W.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2017, 86 (01) : 192 - 201