The biomechanical effects of allograft wedges used for large corrections during medial opening wedge high tibial osteotomy

被引:9
作者
Belsey, James [1 ,2 ]
Kaze, Arnaud Diffo [3 ,4 ]
Jobson, Simon [1 ]
Faulkner, James [1 ]
Maas, Stefan [3 ]
Khakha, Raghbir [2 ]
Pape, Dietrich [4 ]
Wilson, Adrian J. [5 ]
机构
[1] Univ Winchester, Dept Sport Exercise & Hlth, Winchester, Hants, England
[2] Basingstoke & North Hampshire Hosp, Basingstoke, Hants, England
[3] Univ Luxembourg, Fac Sci Technol & Commun, Luxembourg, Luxembourg
[4] Ctr Hosp Luxembourg, Dept Orthopaed Surg, Luxembourg, Luxembourg
[5] Hampshire Clin, Basing Rd, Basingstoke, Hants, England
关键词
FULL WEIGHT-BEARING; FIXATION; FRACTURES; DEVICE;
D O I
10.1371/journal.pone.0216660
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The inclusion of an allograft wedge during medial opening wedge high tibial osteotomy has been shown to lead to satisfactory time-to-union in larger corrections (> 10 degrees). Such large corrections are associated with greater incidences of intraoperative hinge fracture and reduced construct stability. The purpose of this study was to investigate the biomechanical stability that an allograft wedge brings to an osteotomy. Ten medium-size fourth generation artificial sawbone tibiae underwent 12 mm biplanar medial opening wedge high tibial osteotomy with a standard Tomofix plate. Five tibiae had an allograft wedge inserted into the osteotomy gap prior to plate fixation (allograft group). The gap in the remaining tibiae was left unfilled (control group). Each group underwent static compression testing and cyclical fatigue testing until failure of the osteotomy. Peak force, valgus malrotation, number of cycles, displacement and stiffness around the tibial head were analysed. Intraoperative hinge fractures occurred in all specimens. Under static compression, the allograft group withstood higher peak forces (6.01 kN) compared with the control group (5.12 kN). Valgus malrotation was lower, and stiffness was higher, in the allograft group. During cyclical fatigue testing, results within the allograft group were more consistent than within the control group. This may indicate more predictable results in large osteotomies with an allograft. Tibial osteotomies with allograft wedges appear beneficial for larger corrections, and in cases of intraoperative hinge fracture, due to the added construct stability they provide, and the consistency of results compared with tibial osteotomies without a graft.
引用
收藏
页数:14
相关论文
共 32 条
[1]   Results of high tibial osteotomy: review of the literature [J].
Amendola, Annunziato ;
Bonasia, Davide Edoardo .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (02) :155-160
[2]  
Baleani M, 2003, HIP Int, V13, P159
[3]   Medial Opening Wedge High Tibial Osteotomy for Medial Compartment Overload/Arthritis in the Varus Knee Prognostic Factors [J].
Bonasia, Davide Edoardo ;
Dettoni, Federico ;
Sito, Gabriele ;
Blonna, Davide ;
Marmotti, Antongiulio ;
Bruzzone, Matteo ;
Castoldi, Filippo ;
Rossi, Roberto .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (03) :690-698
[4]   Early full weight bearing is safe in open-wedge high tibial osteotomy [J].
Brinkman, Justus-Martijn ;
Luites, Joan W. H. ;
Wymenga, Ate B. ;
van Heerwaarden, Ronald J. .
ACTA ORTHOPAEDICA, 2010, 81 (02) :193-198
[5]   Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: Prospective evaluation of bone union, precision and maintenance of correction in 51 cases [J].
Brosset, T. ;
Pasquier, G. ;
Migaud, H. ;
Gougeon, F. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (07) :705-711
[6]   Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing [J].
Dexel, Julian ;
Fritzsche, Hagen ;
Beyer, Franziska ;
Harman, Melinda K. ;
Luetzner, Joerg .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) :832-837
[7]   Static and fatigue strength of a novel anatomically contoured implant compared to five current open-wedge high tibial osteotomy plates [J].
Diffo Kaze A. ;
Maas S. ;
Belsey J. ;
Hoffmann A. ;
Pape D. .
Journal of Experimental Orthopaedics, 4 (1)
[8]   Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy [J].
Diffo Kaze A. ;
Maas S. ;
Waldmann D. ;
Zilian A. .
Journal of Experimental Orthopaedics, 2 (1) :1-17
[9]   Opening-wedge high tibial osteotomy without bone graft [J].
El-Assal, Maher A. ;
Khalifa, Yaser E. ;
Abdel-Hamid, Mohamed M. ;
Said, Hatem G. ;
Bakr, Hatem M. A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (07) :961-966
[10]   Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia Models [J].
Gardner, Matthew P. ;
Chong, Alexander C. M. ;
Pollock, Anthony G. ;
Wooley, Paul H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) :613-620