Experimental Evaluation of High Intensity Ultrasound Source System using Acoustic Waveguide and Concave Transducer with 100 mm Diameter for Calibration of Hydrophone

被引:0
作者
Igarashi, Shigeru [1 ]
Morishita, Takeshi [2 ]
Takeuchi, Shinichi [2 ]
机构
[1] Polytech Univ, Elect Circuit Engn Unit, Kodaira, Tokyo, Japan
[2] Toin Univ Yokohama, Fac Biomed Engn, Dept Clin Engn, Yokohama, Kanagawa, Japan
来源
2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2018年
关键词
Ultrasound source; Acoustic waveguide; Concave Transducer; Calibration; Hydrophone;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, equipments using high intensity ultrasound have been increasing in medical and industrial fields. A high intensity ultrasound source for calibrating a hydrophone to evaluate a high intensity ultrasound field is required. Especially, to calibrate the receiving sensitivity of the membrane type hydrophone as the primary standard, it is necessary to vibrate the required area of acoustic receiving surface on the primary standard hydrophone uniformly. We proposed and developed a high intensity ultrasound source system using a cylindrical acoustic waveguide and a concave transducer. In this system, the output ultrasound wave forms main beam similar to that formed by a flat type transducer and is expected to increase the ultrasound power acoustically by using of the concave transducer with larger diameter. We constructed an experimental system using an 1 MHz concave transducer with an effective diameter of 40 mm, and confirmed the peak acoustic pressure of 670 kPa at the position of 10 mm from the transmitting aperture. Furthermore, we constructed an experimental system using a concave transducer with an effective diameter of 100 mm, and measured the acoustic pressure distribution on the lateral axis at distances of 10, 20, and 30 mm from the transmitting aperture. As the result, it was confirmed that the -6 dB beam width become almost equal to the conventional source system with the effective diameter of 40 mm and the transmitting sensitivity increased about 2-fold with that.
引用
收藏
页数:4
相关论文
共 21 条
  • [11] Monitoring of high-intensity focused ultrasound treatment by shear wave elastography induced by two-dimensional-array therapeutic transducer
    Iwasaki, Ryosuke
    Takagi, Ryo
    Nagaoka, Ryo
    Jimbo, Hayato
    Yoshizawa, Shin
    Saijo, Yoshifumi
    Umemura, Shin-ichiro
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (07)
  • [12] Kikuchi T., 2009, JPN J MED ULTRASON, V36, P637
  • [13] Development of anticavitation hydrophone using a titanium front plate: Effect of the titanium front plate in high-intensity acoustic field with generation of acoustic cavitation
    Shiiba, Michihisa
    Okada, Nagaya
    Kurosawa, Minoru
    Takeuchi, Shinichi
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (07)
  • [14] Frequency characteristics of receiving sensitivity and waveform of an anti-acoustic cavitation hydrophone
    Shiiba, Michihisa
    Okada, Nagaya
    Uchida, Takeyoshi
    Kikuchi, Tsuneo
    Kurosawa, Minoru
    Takeuchi, Shinichi
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [15] Study on cavitation behavior during high-intensity focused ultrasound exposure by using optical and ultrasonic imaging
    Taguchi, Kei
    Takagi, Ryo
    Yasuda, Jun
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (07)
  • [16] Tangsopa W., 2018, EARTH ENV SCI, V159
  • [17] Control of treatment size in cavitation-enhanced high-intensity focused ultrasound using radio-frequency echo signals
    Tomiyasu, Kentaro
    Takagi, Ryo
    Iwasaki, Ryosuke
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [18] Tsybry K., 2017, MATER SCI ENG, V177
  • [19] Effect of Pretrapping of Microbubbles in Sonoporation Using N-Isopropylacrylamide Gel Flow Channel Phantom
    Yamakoshi, Yoshiki
    Miwa, Takashi
    Yoshizawa, Nobuyuki
    Inoguchi, Hiroki
    Zhang, Dongyu
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (07)
  • [20] Yasuda J., 2016, JPN J APPL PHYS, V55