Measurements of the optical performance of bolometers for SPICA/SAFARI

被引:4
|
作者
Audley, Michael D. [1 ]
de Lange, Gert [1 ]
Gao, Jian-Rong [2 ,3 ]
Khosropanah, Pourya [2 ]
Ridder, Marcel [2 ]
Ferrari, Lorenza [1 ]
Laauwen, Wouter M. [1 ]
Ranjan, Manisha [1 ]
Mauskopf, Philip D. [4 ]
Morozov, Dmitry [4 ]
Trappe, Neil A. [5 ]
机构
[1] SRON Netherlands Inst Space Res, Postbus 800, NL-9700 AV Groningen, Netherlands
[2] SRON Netherlands Inst Space Res, NL-3584 CA Utrecht, Netherlands
[3] Delft Univ Technol, Kavli Inst Nanosci, NL-2628CJ Delft, Netherlands
[4] Cardiff Univ, Sch Phys & Astron, Cardiff CF24 3AA, Wales
[5] Natl Univ Ireland, Dept Expt Phys, Maynooth, Kildare, Ireland
来源
MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI | 2012年 / 8452卷
关键词
Transition edge sensor; bolometer; SAFARI; optical testing; cryogenic illuminator;
D O I
10.1117/12.925234
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We have measured the optical response of detectors designed for SAFARI, the far-infrared imaging spectrometer for the SPICA satellite. To take advantage of SPICA's cooled optics, SAFARI's three bolometer arrays are populated with extremely sensitive (NEP similar to 2x10(-19) W/root Hz) transition edge sensors with a transition temperature close to 100 mK. The extreme sensitivity and low saturation power (similar to 4 fW) of SAFARI's detectors present challenges to characterizing them. We have therefore built up an ultra-low background test facility with a cryogen-free high-capacity dilution refrigerator, paying careful attention to stray-light exclusion. Our use of a pulse-tube cooler to pre-cool the dilution refrigerator required that the SAFARI Detector System Test Facility provide a high degree electrical, magnetic, and mechanical isolation for the detectors. We have carefully characterized the performance of the test facility in terms of background power loading. The test facility has been designed to be flexible and easily reconfigurable with internal illuminators that allow us to characterize the optical response of the detectors. We describe the test facility and some of the steps we took to create an ultra-low background test environment. We have measured the optical response of two detectors designed for SAFARI's short-wave wavelength band in combination with a spherical backshort and conical feedhorn. We find an overall optical efficiency of 40% for both, compared with an ideal-case predicted optical efficiency of 66%.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Exoplanetary Systems with SAFARI: A Far Infrared Imaging Spectrometer for SPICA
    Goicoechea, J. R.
    Swinyard, B.
    PATHWAYS TOWARDS HABITABLE PLANETS, 2010, 430 : 448 - +
  • [32] FPGA-BASED DIGITAL PROCESSING UNIT FOR SPICA SAFARI
    Di Giorgio, A. M.
    Irelli, P. Cerulli
    De Luca, M.
    Nuzzolo, F.
    Orfei, R.
    Spinoglio, L.
    SPICA JOINT EUROPEAN/JAPANESE WORKSHOP, 2009,
  • [33] The DCU: The Detector Control Unit of the SAFARI instrument onboard SPICA
    Clenet, A.
    Ravera, L.
    Bertrand, B.
    Cros, A.
    Hou, R.
    Jackson, B. D.
    van Leeuwen, B. J.
    van Loon, D.
    Parot, Y.
    Pointecouteau, E.
    Sournac, A.
    Ta, N.
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI, 2012, 8452
  • [34] TES Arrays for the Short Wavelength Band of the SAFARI Instrument on SPICA
    Khosropanah, P.
    Hijmering, R.
    Ridder, M.
    Gao, J. R.
    Morozov, D.
    Mauskopf, P. D.
    Trappe, N.
    O'Sullivan, C.
    Murphy, A.
    Griffin, D.
    Goldie, D.
    Glowacka, D.
    Withington, S.
    Jackson, B. D.
    Audley, M. D.
    de Lange, G.
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI, 2012, 8452
  • [35] OBSERVATIONS OF EXOPLANETS TRANSITS IN THE FAR INFRARED WITH SPICA-SAFARI
    Pezzuto, Stefano
    SPICA JOINT EUROPEAN/JAPANESE WORKSHOP, 2009,
  • [36] Simulation of the Cosmic Ray Impact on the TES Detectors of SPICA/SAFARI
    T. A. Stockmans
    A. Almasi
    S. L. Stever
    P. Khosropanah
    Journal of Low Temperature Physics, 2022, 209 : 482 - 492
  • [37] SAFARI new and improved; extending the capabilities of SPICA's Imaging Spectrometer
    SPACE TELESCOPES AND INSTRUMENTATION 2014: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2014, 9143
  • [38] BASEBAND FEEDBACK FOR SAFARI-SPICA USING FREQUENCY DOMAIN MULTIPLEXING
    Bounab, A.
    de Korte, P.
    Cros, A.
    van der Kuur, J.
    van Leeuwen, B. J.
    Monna, B.
    Mossel, R.
    Nieuwenhuizen, A.
    Ravera, L.
    ASTROPHYSICS DETECTOR WORKSHOP 2008, 2009, 37 : 101 - +
  • [39] SAFARI: INSTRUMENT DESIGN OF THE FAR-INFRARED IMAGING SPECTROMETER FOR SPICA
    Jellema, W.
    Pastor, C.
    Naylor, D.
    Jackson, B.
    Sibthorpe, B.
    Roelfsema, P.
    INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [40] Fabrication of Low-Noise TES Arrays for the SAFARI Instrument on SPICA
    M. L. Ridder
    P. Khosropanah
    R. A. Hijmering
    T. Suzuki
    M. P. Bruijn
    H. F. C. Hoevers
    J. R. Gao
    M. R. Zuiddam
    Journal of Low Temperature Physics, 2016, 184 : 60 - 65