The Role of Axial Resolution of Optical Coherence Tomography on the Measurement of Corneal and Epithelial Thicknesses

被引:49
作者
Ge, Lili [1 ]
Yuan, Yimin [1 ]
Shen, Meixiao [1 ]
Tao, Aizhu [1 ]
Wang, Jianhua [2 ]
Lu, Fan [1 ]
机构
[1] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Univ Miami, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL USA
关键词
HIGH-SPEED; TOPOGRAPHICAL THICKNESS; AUTOMATIC SEGMENTATION; REFRACTIVE SURGERY; CONTACT-LENSES; ORBSCAN-II; PACHYMETRY; KERATOCONUS; REPEATABILITY; RELIABILITY;
D O I
10.1167/iovs.11-9308
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Our purpose was to investigate the role of the axial resolution of optical coherence tomography (OCT) on the measurement of corneal and epithelial thickness by evaluating the repeatability and agreement among different OCT devices with different axial resolutions. METHODS. Twenty right eyes of 20 healthy subjects (age: 22.3 +/- 1.3 years) and 18 eyes of 18 patients (age: 25.7 +/- 6.8 years) after laser in situ keratomileusis (LASIK) refractive surgery were tested. Each subject was imaged using four OCT devices: ultra-high resolution OCT (UHR-OCT), ultra-long scan depth OCT (UL-OCT), commercial RTVue, and Visante. The OCT images obtained from UHR-OCT, UL-OCT, and RTVue were processed with a custom automated algorithm for measuring the central corneal thickness (CCT) and central epithelial thickness (ET). CCT measurements from pachymetry maps that were generated by RTVue and Visante were also obtained. RESULTS. For both groups, the CCT and ET measured by UHR-OCT and UL-OCT were highly correlated with RTVue when the automated image processing algorithm was used. The CCT measurements from the RTVue and Visante pachymetry were thicker than those measurements obtained from the automatic algorithm. The coefficient of repeatability was less than 4.9 mu m in the healthy subjects and 7.9 mu m in the LASIK patients, and the associated intraclass correlation coefficient (ICC) was greater than 0.992 in both groups for the CCT measurements. For the ET measurements using UHR-OCT, UL-OCT and RTVue, the coefficient of repeatability was less than 2.2 mu m in the healthy subjects and 4.8 mu m in the LASIK patients with an ICC that was greater than 0.84. CONCLUSIONS. The axial resolution of OCT may play a role in determining the precision with which the CCT and the ET can be measured, although it may not affect the measurement of results. (Invest Ophthalmol Vis Sci. 2013; 54: 746-755) DOI:10.1167/iovs.11-9308
引用
收藏
页码:746 / 755
页数:10
相关论文
共 56 条
[1]   Diagnosis and Management of Conjunctival and Corneal Intraepithelial Neoplasia Using Ultra High-Resolution Optical Coherence Tomography [J].
Abou Shousha, Mohamed ;
Karp, Carol L. ;
Perez, Victor L. ;
Hoffmann, Rodrigo ;
Ventura, Roberta ;
Chang, Victoria ;
Dubovy, Sander R. ;
Wang, Jianhua .
OPHTHALMOLOGY, 2011, 118 (08) :1531-1537
[2]   Use of Ultra-High-Resolution Optical Coherence Tomography to Detect In Vivo Characteristics of Descemet's Membrane in Fuchs' Dystrophy [J].
Abou Shousha, Mohamed ;
Perez, Victor L. ;
Wang, Jianhua ;
Ide, Takeshi ;
Jiao, Shuliang ;
Chen, Qi ;
Chang, Victoria ;
Buchser, Nancy ;
Dubovy, Sander R. ;
Feuer, William ;
Yoo, Sonia H. .
OPHTHALMOLOGY, 2010, 117 (06) :1220-1227
[3]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Ultrahigh-Resolution Measurement by Optical Coherence Tomography of Dynamic Tear Film Changes on Contact Lenses [J].
Chen, Qi ;
Wang, Jianhua ;
Tao, Aizhu ;
Shen, Meixiao ;
Jiao, Shuliang ;
Lu, Fan .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (04) :1988-1993
[6]   Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry [J].
Chen, Shihao ;
Huang, Jinhai ;
Wen, Daizong ;
Chen, Wuhe ;
Huang, David ;
Wang, Qinmei .
ACTA OPHTHALMOLOGICA, 2012, 90 (05) :449-455
[7]   POSITIVE CORRELATION OF CORNEAL THICKNESS AND ENDOTHELIAL-CELL LOSS - SERIAL MEASUREMENTS AFTER CATARACT-SURGERY [J].
CHENG, H ;
BATES, AK ;
WOOD, L ;
MCPHERSON, K .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (07) :920-922
[8]   Ultrahigh-resolution optical coherence tomography [J].
Drexler, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :47-74
[9]   Vertical and Horizontal Corneal Epithelial Thickness Profiles Determined by Ultrahigh Resolution Optical Coherence Tomography [J].
Du, Chixin ;
Wang, Jianhua ;
Cui, Lele ;
Shen, Meixiao ;
Yuan, Yimin .
CORNEA, 2012, 31 (09) :1036-1043
[10]   Corneal, limbal, and conjunctival epithelial thickness from Optical Coherence Tomography [J].
Feng, Yunwei ;
Simpson, Trefford L. .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (09) :880-883