Effect of successful coronary angioplasty and stent implantation on QT dispersion

被引:12
|
作者
Yesilbursa, D [1 ]
Serdar, A [1 ]
Aydinlar, A [1 ]
机构
[1] Uludag Univ, Fac Med, Dept Cardiol, Bursa, Turkey
关键词
QT dispersion; coronary angioplasty; stent implantation;
D O I
10.1097/00019501-199907000-00010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background QT dispersion (defined as maximal QT interval minus minimal QT interval), as assessed using the surface EGG, has been shown to reflect regional inhomogeneities in ventricular repolarization. The aim of this study was to show the effect of coronary revascularization, by successful coronary angioplasty or stent implantation, on QT dispersion. Methods QT dispersion was defined on each ECG as the difference between the maximal and minimal measurements of QT interval. Of 135 patients studied, 52 patients underwent coronary angioplasty and 84 patients underwent stent implantation. Maximum and minimal QT interval and QT dispersion were measured using 12-lead electrocardiography before and 24 h after each successful procedure. Results QT dispersion decreased from 51 +/- 12 ms at baseline to 37 +/- 10 ms 24 after the procedure (P < 0.001). Before the procedure, the QT dispersion of patients undergoing angioplasty and stent implantation was 50 +/- 13 and 52 +/- 10 ms, respectively After the procedure, the QT dispersions were 34 +/- 9 and 38 +/- 10 ms, respectively (P<0.001). QT dispersion was significantly lower in both groups after the procedure, No differences were observed between the QT dispersions of patients undergoing angioplasty and of those undergoing stent implantation. Conclusions Successful coronary angioplasty and stent implantation significantly reduced QT dispersion. The decreased QT dispersion may have been caused by improvements in myocardial perfusion and may be beneficial in reducing the likelihood of arrhythmias occurring. Coronary Artery Dis 10:335-337 (C) 1999 Lippincott Williams & Wilkins.
引用
收藏
页码:335 / 337
页数:3
相关论文
共 50 条
  • [41] Stent implantation reduces restenosis in patients with suboptimal results following coronary angioplasty
    Knight, CJ
    Curzen, NP
    Groves, PH
    Patel, DJ
    Goodall, AH
    Wright, C
    Clarke, D
    Oldershaw, PJ
    Fox, KM
    EUROPEAN HEART JOURNAL, 1999, 20 (24) : 1783 - 1790
  • [42] A randomized comparison of balloon angioplasty and stent implantation in the percutaneous treatment of coronary bifurcations
    Dens, J
    Dubois, C
    Vermeersch, P
    Coussement, P
    Vrolix, M
    Janssens, L
    Desmet, W
    Piessens, J
    ACTA CARDIOLOGICA, 2005, 60 (04) : 379 - 385
  • [43] Comparative pathologic studies of chronic tissue responses to successful stent implantation and balloon angioplasty
    Inoue, K
    Ando, K
    Shirai, S
    Nakanishi, M
    Yokoi, H
    Nakagawa, Y
    Hamasaki, N
    Kimura, T
    Nosaka, H
    Nobuyoshi, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 83A - 83A
  • [44] The effect of epinephrine and coronary occlusion on QT dispersion.
    Cao, W
    Ranade, V
    Somberg, JC
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (07) : A349 - A349
  • [45] THE EFFECT OF TIROFIBAN ON QT DISPERSION IN ACUTE CORONARY SYNDROMES
    Ozbay, Y.
    Akbulut, M.
    Kutlu, M.
    Erdem, K.
    Kobat, M. A.
    Cekici, Y.
    ATHEROSCLEROSIS SUPPLEMENTS, 2008, 9 (01) : 218 - 219
  • [46] Comparison of the Efficacies of Irbesartan and Olmesartan after Successful Coronary Stent Implantation
    Morii, Joji
    Miura, Shin-ichiro
    Ike, Amane
    Shiga, Yuhei
    Sugihara, Makoto
    Iwata, Atsushi
    Kawamura, Akira
    Nishikawa, Hiroaki
    Saku, Keijiro
    INTERNAL MEDICINE, 2013, 52 (07) : 713 - 719
  • [47] QT interval dispersion as a new marker of restenosis after percutaneous transluminal coronary angioplasty
    Grygier, M
    Lesiak, M
    Podzerek, T
    Kowal, J
    Pyda, M
    Skorupski, W
    Grajek, S
    Cieslinski, A
    EUROPEAN HEART JOURNAL, 2003, 24 : 684 - 684
  • [48] QT dispersion before and after coronary artery angioplasty: A case study from Iran
    Monshizadeh, E.
    Arefi, H.
    Moghadam, M.
    Hassanijirdehi, M.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2012, 61 (01): : 27 - 31
  • [49] Coronary artery aneurysm development after successful primary stent implantation
    Nisanci, Y
    Coskun, I
    Oncul, A
    Umman, S
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 42 (04): : 420 - 422
  • [50] QT interval dispersion as a new marker of restenosis after percutaneous transluminal coronary angioplasty
    Krishnamoorthy, K. M.
    Dash, P. K.
    CARDIOLOGY, 2007, 108 (01) : 71 - 72