Effect of successful coronary angioplasty and stent implantation on QT dispersion

被引:12
|
作者
Yesilbursa, D [1 ]
Serdar, A [1 ]
Aydinlar, A [1 ]
机构
[1] Uludag Univ, Fac Med, Dept Cardiol, Bursa, Turkey
关键词
QT dispersion; coronary angioplasty; stent implantation;
D O I
10.1097/00019501-199907000-00010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background QT dispersion (defined as maximal QT interval minus minimal QT interval), as assessed using the surface EGG, has been shown to reflect regional inhomogeneities in ventricular repolarization. The aim of this study was to show the effect of coronary revascularization, by successful coronary angioplasty or stent implantation, on QT dispersion. Methods QT dispersion was defined on each ECG as the difference between the maximal and minimal measurements of QT interval. Of 135 patients studied, 52 patients underwent coronary angioplasty and 84 patients underwent stent implantation. Maximum and minimal QT interval and QT dispersion were measured using 12-lead electrocardiography before and 24 h after each successful procedure. Results QT dispersion decreased from 51 +/- 12 ms at baseline to 37 +/- 10 ms 24 after the procedure (P < 0.001). Before the procedure, the QT dispersion of patients undergoing angioplasty and stent implantation was 50 +/- 13 and 52 +/- 10 ms, respectively After the procedure, the QT dispersions were 34 +/- 9 and 38 +/- 10 ms, respectively (P<0.001). QT dispersion was significantly lower in both groups after the procedure, No differences were observed between the QT dispersions of patients undergoing angioplasty and of those undergoing stent implantation. Conclusions Successful coronary angioplasty and stent implantation significantly reduced QT dispersion. The decreased QT dispersion may have been caused by improvements in myocardial perfusion and may be beneficial in reducing the likelihood of arrhythmias occurring. Coronary Artery Dis 10:335-337 (C) 1999 Lippincott Williams & Wilkins.
引用
收藏
页码:335 / 337
页数:3
相关论文
共 50 条
  • [31] QT dispersion plus ST-segment depression: A new predictor of restenosis after successful percutaneous transluminal coronary angioplasty
    Aytemir, K
    Özer, N
    Aksöyek, S
    Özkutlu, H
    Oto, A
    Özmen, F
    CLINICAL CARDIOLOGY, 1999, 22 (06) : 409 - 412
  • [32] Intravenous nicorandil can reduce the occurrence of ventricular fibrillation and QT dispersion in patients with successful coronary angioplasty in acute myocardial infarction
    Ueda, H
    Nakayama, Y
    Tsumura, K
    Yoshimaru, K
    Hayashi, T
    Yoshikawa, J
    CANADIAN JOURNAL OF CARDIOLOGY, 2004, 20 (06) : 625 - 629
  • [33] THE EFFECT OF SUCCESSFUL CORONARY ANGIOPLASTY ON FEELINGS OF EXHAUSTION
    KOP, WJ
    APPELS, APWM
    DELEON, CFM
    DESWART, H
    BAR, FW
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1993, 42 (03) : 269 - 276
  • [34] RELATIONSHIP OF CHANGES OF QT DISPERSION AND PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY ON SHORT TIME
    Zhenxu Yang Min Li Yongshong SongCentral Hospitalof Feicheng Cale MineTaian China
    中国介入心脏病学杂志, 1998, (04) : 186 - 186
  • [35] Nicorandil, a potent cardioprotective agent, reduces QT dispersion during coronary angioplasty
    Kato, T
    Kamiyama, T
    Maruyama, Y
    Tanaka, S
    Yoshimoto, N
    AMERICAN HEART JOURNAL, 2001, 141 (06) : 940 - 943
  • [36] Cutting balloon angioplasty is superior to balloon angioplasty or stent implantation for small coronary artery disease
    Iijima, R
    Ikari, Y
    Wada, M
    Shiba, M
    Nakamura, M
    Hara, K
    CORONARY ARTERY DISEASE, 2004, 15 (07) : 435 - 440
  • [37] Effect of balloon inflation-induced acute ischemia on QT dispersion during percutaneous transluminal coronary angioplasty
    Aytemir, K
    Bavafa, V
    Ozer, N
    Aksoyek, S
    Oto, A
    Ozmen, F
    CLINICAL CARDIOLOGY, 1999, 22 (01) : 21 - 24
  • [38] QT dispersion and prognosis after coronary stent placement in acute myocardial infarction
    Ueda, Hiroyasu
    Hayashi, Tomoshige
    Tsumura, Kei
    Kaitani, Kazuaki
    Yoshimaru, Kiyomichi
    Nakayama, Yasunori
    Yoshiyama, Minoru
    CLINICAL CARDIOLOGY, 2007, 30 (05) : 229 - 233
  • [39] CORONARY STENT IMPLANTATION IN ACUTE VESSEL CLOSURE 48 HOURS AFTER AN UNSATISFACTORY CORONARY ANGIOPLASTY
    HAUDE, M
    ERBEL, R
    STRAUB, U
    DIETZ, U
    SCHATZ, R
    MEYER, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 21 (04): : 263 - 265
  • [40] Self-expanding coronary Stent (radius) implantation with cutting balloon angioplasty
    Lee, SH
    Choi, SH
    Ko, YG
    Choi, DH
    Jang, YS
    Shim, WH