Effect of successful coronary angioplasty and stent implantation on QT dispersion

被引:12
|
作者
Yesilbursa, D [1 ]
Serdar, A [1 ]
Aydinlar, A [1 ]
机构
[1] Uludag Univ, Fac Med, Dept Cardiol, Bursa, Turkey
关键词
QT dispersion; coronary angioplasty; stent implantation;
D O I
10.1097/00019501-199907000-00010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background QT dispersion (defined as maximal QT interval minus minimal QT interval), as assessed using the surface EGG, has been shown to reflect regional inhomogeneities in ventricular repolarization. The aim of this study was to show the effect of coronary revascularization, by successful coronary angioplasty or stent implantation, on QT dispersion. Methods QT dispersion was defined on each ECG as the difference between the maximal and minimal measurements of QT interval. Of 135 patients studied, 52 patients underwent coronary angioplasty and 84 patients underwent stent implantation. Maximum and minimal QT interval and QT dispersion were measured using 12-lead electrocardiography before and 24 h after each successful procedure. Results QT dispersion decreased from 51 +/- 12 ms at baseline to 37 +/- 10 ms 24 after the procedure (P < 0.001). Before the procedure, the QT dispersion of patients undergoing angioplasty and stent implantation was 50 +/- 13 and 52 +/- 10 ms, respectively After the procedure, the QT dispersions were 34 +/- 9 and 38 +/- 10 ms, respectively (P<0.001). QT dispersion was significantly lower in both groups after the procedure, No differences were observed between the QT dispersions of patients undergoing angioplasty and of those undergoing stent implantation. Conclusions Successful coronary angioplasty and stent implantation significantly reduced QT dispersion. The decreased QT dispersion may have been caused by improvements in myocardial perfusion and may be beneficial in reducing the likelihood of arrhythmias occurring. Coronary Artery Dis 10:335-337 (C) 1999 Lippincott Williams & Wilkins.
引用
收藏
页码:335 / 337
页数:3
相关论文
共 50 条
  • [1] Effect of coronary angioplasty on QT dispersion
    Kelly, RF
    Parillo, JE
    Hollenberg, SM
    AMERICAN HEART JOURNAL, 1997, 134 (03) : 399 - 405
  • [2] Effect of repeated coronary angioplasty on QT dispersion
    Soliman, E. Z.
    Abdel-Salam, M.
    CIRCULATION, 2008, 118 (12) : E241 - E241
  • [3] Effect of coronary angioplasty on precordial QT dispersion
    Yunus, A
    Gillis, AM
    Traboulsi, M
    Duff, HJ
    Wyse, DG
    Knudtson, ML
    Mitchell, LB
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (10): : 1339 - 1342
  • [4] CORONARY ANGIOPLASTY WITH STENT IMPLANTATION
    TEBBE, U
    SCHATZ, RA
    SCHOLZ, KH
    BRUNE, S
    SAUER, G
    KREUZER, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1990, 115 (27) : 1054 - 1058
  • [5] The effect of acute coronary occlusion at angioplasty on QT dispersion.
    Tarabey, R
    Sukenik, D
    Syed, M
    Molnar, J
    Somberg, J
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (07) : A374 - A374
  • [6] Clinical outcome after successful coronary angioplasty: Impact of intracoronary stent implantation
    Nilsson, JB
    Eriksson, A
    Ramberg, CJ
    Eriksson, P
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (02) : 178 - 181
  • [7] REDUCTION IN QT INTERVAL DISPERSION BY SUCCESSFUL CORONARY ANGIOPLASTY IN UNSTABLE ANGINA OR MYOCARDIAL INFACTION
    Yasping Lan Changzong Chui Dongqi Wang Rirst Teaching Hospital Xian Mediacl UniversityXian China
    中国介入心脏病学杂志, 1998, (04) : 183 - 183
  • [8] Stent implantation after successful balloon angioplasty of a chronic coronary occlusion - A randomized trial
    Sievert, H
    Rohde, S
    Schulze, R
    Utech, A
    Ensslen, R
    Spies, H
    Scherer, D
    Schrader, R
    Merle, H
    Fach, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 90427 - 90427
  • [9] Effect of intracoronary balloon inflation at percutaneous transluminal coronary angioplasty on QT dispersion
    Tarabey, R
    Sukenik, D
    Molnar, J
    Somberg, JC
    AMERICAN HEART JOURNAL, 1998, 135 (03) : 519 - 522
  • [10] Shortening of prolonged QT dispersion after coronary angioplasty
    Daniarov, B
    Hilbel, T
    Brachmann, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 88152 - 88152