Influence of ion stimulated gas desorption from residual gas analyzer on partial pressure measurement

被引:2
|
作者
Kurokouchi, S
Kato, S
机构
[1] RIKEN, Inst Phys & Chem Res, Wako, Saitama 3510106, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS | 2001年 / 19卷 / 06期
关键词
D O I
10.1116/1.1407241
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The influence of ion stimulated gas desorption (ISD) from the ion-extraction plate of a residual gas analyzer (RGA) ion source on partial pressure measurement was evaluated, using a modified RGA. ISD from the extraction plate occurs due to bombardment with ionized gas molecules, and is thought to be closely related to physical sputtering and chemical reactions on the plate surface. Our experimental results indicate that partial pressure detection limits deteriorate due to an ISD signal increase, which in turn is dependent on total pressure, the species and kinetic energy of the ion, and the temperature of the ion-extraction plate. Where the ion-extraction plate is heated to 250 degreesC and the dominant gas species is massive or reactive, ISD signals account for an amount on the order of 100 ppm of partial pressure signal intensity. This ISD problem can affect the accuracy of partial pressure measurement in all pressure ranges. However, there are several methods to reduce ISD. Among the possible methods, a simple modification of the ion source to restrict the ion-bombarded area would diminish ISD the most effectively. (C) 2001 American Vacuum Society.
引用
收藏
页码:2820 / 2825
页数:6
相关论文
共 50 条
  • [1] Residual gas analyzer
    不详
    MICRO, 1995, 13 (10): : 24 - &
  • [2] Residual gas analyzer
    不详
    MICRO, 1995, 13 (02): : 47 - 47
  • [3] ION CURRENT MODULATION OF A RESIDUAL-GAS ANALYZER
    WATANABE, F
    ISHIMARU, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1985, 3 (06): : 2192 - 2195
  • [4] STUDY ON MAXIMUM TOLERABLE PRESSURE IN A RESIDUAL GAS ANALYZER
    WERNER, HW
    LINSSEN, AJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1974, 11 (04): : 843 - 847
  • [5] Measurement of partial pressures in extremely high vacuum region using a modified residual gas analyzer
    Watanabe, S
    Oyama, H
    Kato, S
    Aono, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1880 - 1884
  • [6] Influence of the Residual Gas Composition and the Getter-Ion Effect on the Measurement of the Internal Pressure in Vacuum Interrupters
    Eichhoff, D.
    Gentsch, D.
    Weuffel, M.
    Schnettler, A.
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 457 - 460
  • [7] PARTIAL PRESSURE CALIBRATION FOR RESIDUAL GAS ANALYZERS
    MORRISON, CF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1969, 6 (01): : 79 - &
  • [8] PARTIAL PRESSURE CALIBRATION FOR RESIDUAL GAS ANALYZERS
    MORRISON, CF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1968, 5 (05): : 173 - &
  • [9] Deuterium Gas Analysis by Residual Gas Analyzer
    Das, B. K.
    Shukla, R.
    Das, R.
    Shyam, A.
    Rao, A. D. P.
    INTERNATIONAL SYMPOSIUM ON VACUUM SCIENCE AND TECHNOLOGY AND ITS APPLICATION FOR ACCELERATORS (IVS 2012), 2012, 390
  • [10] APPLICATION OF ION COUNTING TECHNIQUES TO AN UHV RESIDUAL GAS ANALYZER
    TORNEY, FL
    ROEHRIG, JR
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1969, 6 (05): : 906 - &