Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences

被引:8
|
作者
Liu, Jin [1 ]
Wei, Yang [2 ]
Ma, Ya-Jun [3 ]
Zhu, Yan-Chun [3 ]
Zhou, Quan [1 ]
Zhao, Ying-Hua [1 ,3 ]
机构
[1] Southern Med Univ, Dept Radiol, Affiliated Hosp 3, Acad Orthoped, Guangzhou 510630, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
Ultrashort echo time; T2*relaxation time; Zone of calcified cartilage; Articular cartilage; ARTICULAR-CARTILAGE; SUBCHONDRAL BONE; RESOLUTION;
D O I
10.1097/CM9.0000000000000103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The zone of calcified cartilage (ZCC) plays an important role in the pathogenesis of osteoarthritis (OA) but has never been imaged in vivo with magnetic resonance (MR) imaging techniques. We investigated the feasibility of direct imaging of the ZCC in both cadaveric whole knee specimens and in vivo healthy knees using a 3-dimensional ultrashort echo time cones (3D UTE-Cones) sequence on a clinical 3T scanner. Methods: In all, 12 cadaveric knee joints and 10 in vivo healthy were collected. At a 3T MR scanner with an 8-channel knee coil, a fat-saturated 3D dual-echo UTE-Cones sequence was used to image the ZCC, following with a short rectangular pulse excitation and 3D spiral sampling with conical view ordering. The regions of interests (ROIs) were delineated by a blinded observer. Single-component T2* and T2 values were calculated from fat-saturated 3D dual-echo UTE-Cones and a Carr-Purcell-Meiboom-Gill (T2 C:PMG) data using a semi-automated MATLAB code. Results: The single-exponential fitting curve of ZCC was accurately obtained with R2 of 0.989. For keen joint samples, the ZCC has a short T2* ranging from 0.62 to 2.55 ms, with the mean +/- standard deviation (SD) of 1.49 +/- 0.66 ms, and with 95% confidence intervals (CI) of 1.20-1.78 ms. For volunteers, the short T2* ranges from 0.93 to 3.52 ms, with the mean +SD of 2.09 +/- 0.56 ms, and the 95% CI is 1.43 to 2.74 ms in ZCC. Conclusions: The high-resolution 3D UTE-Cones sequence might be used to directly image ZCC in the human knee joint on a clinical 3T scanner with a scan time of more than 10 min. Using this non-invasive technique, the T2* relaxation time of the ZCC can he further detected.
引用
收藏
页码:562 / 568
页数:7
相关论文
共 50 条
  • [31] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Sun, Yan
    Chen, Yujie
    Li, Xuesheng
    Liao, Yi
    Chen, Xijian
    Song, Yu
    Liang, Xinyue
    Dai, Yongming
    Chen, Dapeng
    Ning, Gang
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [32] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Yan Sun
    Yujie Chen
    Xuesheng Li
    Yi Liao
    Xijian Chen
    Yu Song
    Xinyue Liang
    Yongming Dai
    Dapeng Chen
    Gang Ning
    BMC Medical Imaging, 23
  • [33] Deep Convolutional Neural Network for Dedicated Regions-of-Interest Based Multi-Parameter Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Knee Joint
    Lu, Xing
    Ma, Yajun
    Chang, Eric Y.
    Athertya, Jiyo
    Jang, Hyungseok
    Jerban, Saeed
    Covey, Dana C.
    Bukata, Susan
    Chung, Christine B.
    Du, Jiang
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (05): : 2126 - 2134
  • [34] Tibial cartilage volume measurement in knee osteoarthritis using magnetic resonance imaging
    Vanichtantikul, Varalee
    Hongvilai, Sarit
    Numkarunarunrote, Numphung
    ASIAN BIOMEDICINE, 2015, 9 (01) : 41 - 47
  • [35] Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures
    Hao Wu
    Yu-min Zhong
    Quan-min Nie
    Wei-bo Chen
    Lie-mei Guo
    Xi Yang
    Hong Zhang
    Yi Lin
    Jian-rong Xu
    Yong-ming Dai
    Ming Zhu
    European Radiology, 2016, 26 : 138 - 146
  • [36] Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures
    Wu, Hao
    Zhong, Yu-min
    Nie, Quan-min
    Chen, Wei-bo
    Guo, Lie-mei
    Yang, Xi
    Zhang, Hong
    Lin, Yi
    Xu, Jian-rong
    Dai, Yong-ming
    Zhu, Ming
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 138 - 146
  • [37] Macromolecular fraction (MMF) from 3D ultrashort echo time cones magnetization transfer (3D UTE-Cones-MT) imaging predicts meniscal degeneration and knee osteoarthritis
    Zhang, X.
    Ma, Y. -J.
    Wei, Z.
    Wu, M.
    Ashir, A.
    Jerban, S.
    Li, S.
    Chang, E. Y.
    Du, J.
    OSTEOARTHRITIS AND CARTILAGE, 2021, 29 (08) : 1173 - 1180
  • [38] Cartilage Thickness of the Knee Joint in Juvenile Idiopathic Arthritis: Comparative Assessment by Ultrasonography and Magnetic Resonance Imaging
    Pradsgaard, Dan Ostergaard
    Fiirgaard, Bente
    Spannow, Anne Helen
    Heuck, Carsten
    Herlin, Troels
    JOURNAL OF RHEUMATOLOGY, 2015, 42 (03) : 534 - 540
  • [39] Comparison of T2*mapping between regular echo time and ultrashort echo time with 3D cones at 3 tesla for knee meniscus
    Yi, Jisook
    Lee, Young Han
    Song, Ho-Taek
    Suh, Jin-Suck
    MEDICINE, 2018, 97 (48)
  • [40] Quantitative magnetization transfer ultrashort echo time imaging using a time-efficient 3D multispoke Cones sequence
    Ma, Ya-Jun
    Chang, Eric Y.
    Carl, Michael
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 692 - 700