Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences

被引:8
|
作者
Liu, Jin [1 ]
Wei, Yang [2 ]
Ma, Ya-Jun [3 ]
Zhu, Yan-Chun [3 ]
Zhou, Quan [1 ]
Zhao, Ying-Hua [1 ,3 ]
机构
[1] Southern Med Univ, Dept Radiol, Affiliated Hosp 3, Acad Orthoped, Guangzhou 510630, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
Ultrashort echo time; T2*relaxation time; Zone of calcified cartilage; Articular cartilage; ARTICULAR-CARTILAGE; SUBCHONDRAL BONE; RESOLUTION;
D O I
10.1097/CM9.0000000000000103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The zone of calcified cartilage (ZCC) plays an important role in the pathogenesis of osteoarthritis (OA) but has never been imaged in vivo with magnetic resonance (MR) imaging techniques. We investigated the feasibility of direct imaging of the ZCC in both cadaveric whole knee specimens and in vivo healthy knees using a 3-dimensional ultrashort echo time cones (3D UTE-Cones) sequence on a clinical 3T scanner. Methods: In all, 12 cadaveric knee joints and 10 in vivo healthy were collected. At a 3T MR scanner with an 8-channel knee coil, a fat-saturated 3D dual-echo UTE-Cones sequence was used to image the ZCC, following with a short rectangular pulse excitation and 3D spiral sampling with conical view ordering. The regions of interests (ROIs) were delineated by a blinded observer. Single-component T2* and T2 values were calculated from fat-saturated 3D dual-echo UTE-Cones and a Carr-Purcell-Meiboom-Gill (T2 C:PMG) data using a semi-automated MATLAB code. Results: The single-exponential fitting curve of ZCC was accurately obtained with R2 of 0.989. For keen joint samples, the ZCC has a short T2* ranging from 0.62 to 2.55 ms, with the mean +/- standard deviation (SD) of 1.49 +/- 0.66 ms, and with 95% confidence intervals (CI) of 1.20-1.78 ms. For volunteers, the short T2* ranges from 0.93 to 3.52 ms, with the mean +SD of 2.09 +/- 0.56 ms, and the 95% CI is 1.43 to 2.74 ms in ZCC. Conclusions: The high-resolution 3D UTE-Cones sequence might be used to directly image ZCC in the human knee joint on a clinical 3T scanner with a scan time of more than 10 min. Using this non-invasive technique, the T2* relaxation time of the ZCC can he further detected.
引用
收藏
页码:562 / 568
页数:7
相关论文
共 50 条
  • [21] Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging
    Afsahi, Amir Masoud
    Ma, Yajun
    Jang, Hyungseok
    Jerban, Saeed
    Chung, Christine B.
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (06) : 1597 - 1612
  • [22] Comparative analysis of magnetic resonance imaging in normal and osteoarthritis cartilage of the knee joint
    Guo, Juan
    Wang, Xiaodong
    Qian, Lixia
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (12): : 9706 - 9712
  • [23] Three-dimensional ultrashort echo time cones T1ρ (3D UTE-cones-T1ρ) imaging
    Ma, Ya-Jun
    Carl, Michael
    Shao, Hongda
    Tadros, Anthony S.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2017, 30 (06)
  • [24] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Ha, Ji Young
    Ryu, Kyeong Hwa
    Kim, Ho Cheol
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2253 - 2262
  • [25] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Ji Young Ha
    Kyeong Hwa Ryu
    Ho Cheol Kim
    European Radiology, 2019, 29 : 2253 - 2262
  • [26] Ultrashort echo time magnetization transfer imaging of knee cartilage and meniscus after long-distance running
    Zhu, Dantian
    Wu, Wenhao
    Yu, Wenjun
    Hong, Guobin
    Fang, Yijie
    Li, Shaolin
    Ma, Yajun
    EUROPEAN RADIOLOGY, 2023, 33 (07) : 4842 - 4854
  • [27] Magnetic resonance imaging of short T2 relaxation components in tissue using ultrashort echo time (UTE) pulse sequences
    Bydder, M
    Znamirowski, RM
    Bydder, GM
    CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (01) : 79 - 90
  • [28] Clinical application of ultrashort echo time (UTE) and zero echo time (ZTE) magnetic resonance (MR) imaging in the evaluation of osteoarthritis
    Cheng, Karen Y. Y.
    Moazamian, Dina
    Ma, Yajun
    Jang, Hyungseok
    Jerban, Saeed
    Du, Jiang
    Chung, Christine B. B.
    SKELETAL RADIOLOGY, 2023, 52 (11) : 2149 - 2157
  • [29] Quantitative 3D Ultrashort Echo Time Magnetization Transfer Imaging for Evaluation of Knee Cartilage Degeneration In Vivo
    Xue, Yan-Ping
    Ma, Ya-Jun
    Wu, Mei
    Jerban, Saeed
    Wei, Zhao
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (04) : 1294 - 1302
  • [30] Magic angle effect on adiabatic T1ρ imaging of the Achilles tendon using 3D ultrashort echo time cones trajectory
    Wu, Mei
    Ma, Yajun
    Wan, Lidi
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (08)