Retinal Nerve Fiber Layer Converges More Convexly on Normal Smaller Optic Nerve Head

被引:3
作者
Jung, Kyoung In [1 ]
Shin, Jeong Ah [1 ]
Park, Hae-Young Lopilly [1 ]
Park, Chan Kee [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
关键词
convexity; cup-to-disc ratio; optic disc size; optic nerve head; retinal nerve fiber layer; retinal nerve fiber layer configuration; NEURORETINAL RIM; COHERENCE TOMOGRAPHY; DISK SIZE; THICKNESS; CUP; REPRODUCIBILITY; DIAMETER; GLAUCOMA; AREA; CLASSIFICATION;
D O I
10.1097/IJG.0000000000000011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To investigate retinal nerve fiber layer (RNFL) configuration in the optic nerve head (ONH) and peripapillary area according to disc size and to determine whether it explains cup discrepancy among eyes with different disc sizes.Methods:Horizontal and vertical RNFL curvature and mean thickness were measured using confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph) in 63 normal subjects grouped by disc size. Average and quadrant RNFL thickness, disc size, average cup-to-disc ratio (CDR), and convergence angle at the optic disc were also measured using Cirrus HD-optical coherence tomography. The relationships between disc size and RNFL curvature, thickness, angle at optic disc, and CDR were evaluated. RNFL curvature and convergence angle reflects convexity on and into the optic disc, respectively.Results:CDR was smaller for small discs and was positively correlated with disc size (P<0.001). Horizontal and vertical RNFL curvatures were significantly more convex for small than large discs (P=0.001, 0.017). Horizontal and vertical RNFL angles at the optic disc were positively correlated with disc size (P<0.001, P=0.012). Optic disc area was negatively correlated with mean RNFL thickness at the optic disc margin measured by HRT (P=0.002), but not in the peripapillary area by optical coherence tomography.Conclusions:Using imaging techniques, we demonstrated that the shape of the RNFLs converging on and entering into the optic disc was more convex for small optic discs compared with large discs. A low CDR for small discs could be mediated by these RNFL profiles at the ONH, which may guide the clinical evaluation of glaucomatous ONH damage.
引用
收藏
页码:448 / 454
页数:7
相关论文
共 35 条
[1]  
AIRAKSINEN PJ, 1985, AM J OPHTHALMOL, V99, P1
[2]  
BENGTSSON B, 1976, ACTA OPHTHALMOL, V54, P804
[3]   BIOMETRIC STUDY OF THE DISK CUP IN OPEN-ANGLE GLAUCOMA [J].
BETZ, P ;
CAMPS, F ;
COLLIGNONBRACH, J ;
LAVERGNE, G ;
WEEKERS, R .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1982, 218 (02) :70-74
[4]   THE AREA OF THE NEURORETINAL RIM OF THE OPTIC-NERVE IN NORMAL EYES [J].
BRITTON, RJ ;
DRANCE, SM ;
SCHULZER, M ;
DOUGLAS, GR ;
MAWSON, DK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (04) :497-504
[5]   Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT [J].
Budenz, Donald L. ;
Anderson, Douglas R. ;
Varma, Rohit ;
Schuman, Joel ;
Cantor, Louis ;
Savell, Jonathan ;
Greenfeld, David S. ;
Patella, Vincent Michael ;
Quigley, Harry A. ;
Tielsch, James .
OPHTHALMOLOGY, 2007, 114 (06) :1046-1052
[6]   LASER SCANNING TOMOGRAPHY AND STEREOPHOTOGRAMMETRY IN 3-DIMENSIONAL OPTIC DISC ANALYSIS [J].
BURK, ROW ;
ROHRSCHNEIDER, K ;
TAKAMOTO, T ;
VOLCKER, HE ;
SCHWARTZ, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (04) :193-198
[7]   Topographic differences between large and normal optic discs: a confocal scanning laser ophthalmoscopy study [J].
Cankaya, Ali Bulent ;
Simsek, Tuley .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (01) :63-69
[8]  
CAPRIOLI J, 1987, ARCH OPHTHALMOL-CHIC, V105, P1683
[9]   Custom measurement of retinal nerve fiber layer thickness using STRATUS OCT in normal eyes [J].
Carpineto, P ;
Ciancaglini, M ;
Aharrh-Gnama, A ;
Cirone, D ;
Mastropasqua, L .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (03) :360-366
[10]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836