Wrist-based cut-points for moderate- and vigorous-intensity physical activity for the Actical accelerometer in adults

被引:14
|
作者
Diaz, Keith M. [1 ]
Krupka, David J. [1 ]
Chang, Melinda J. [1 ]
Kronish, Ian M. [1 ]
Moise, Natalie [1 ]
Goldsmith, Jeff [2 ]
Schwartz, Joseph E. [1 ,3 ]
机构
[1] Columbia Univ, Dept Med, Med Ctr, Ctr Behav Cardiovasc Hlth, New York, NY 10032 USA
[2] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY 10032 USA
[3] SUNY Stony Brook, Dept Psychiat, Stony Brook, NY 11794 USA
基金
美国国家卫生研究院;
关键词
Physical activity; accelerometer; calibration; validation; adults; OPERATING CHARACTERISTIC CURVES; SEDENTARY BEHAVIOR; OLDER-ADULTS; CALIBRATION; HIP; VALIDATION; VALIDITY; WALKING; AGE;
D O I
10.1080/02640414.2017.1293279
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Wrist-based accelerometers are increasingly used to assess physical activity (PA) in population-based studies; however, cut-points to translate wrist-based accelerometer counts into PA intensity categories are still needed. The purpose of this study was to determine wrist-based cut-points for moderate-and vigorous-intensity ambulatory PA in adults for the Actical accelerometer. Healthy adults (n = 24) completed a four-phase treadmill exercise protocol (1.9, 3.0, 4.0 and 5.2 mph) while wearing an Actical accelerometer on their wrist. Metabolic equivalent of task (MET) levels were assessed by indirect calorimetry. Receiver operating characteristics (ROC) curves were generated to determine accelerometer counts that maximised sensitivity and specificity for classification of moderate (>= 3 METs) and vigorous (>6 METs) ambulatory activity. The area under the ROC curves to discriminate moderate-and vigorous-intensity ambulatory activity were 0.93 (95% confidence interval [CI]: 0.90-0.97; P < 0.001) and 0.96 (95% CI: 0.94-0.99; P < 0.001), respectively. The identified cut-point for moderate-intensity ambulatory activity was 1031 counts per minute, which had a corresponding sensitivity and specificity of 85.6% and 87.5%, respectively. The identified cut-point for vigorous intensity ambulatory activity was 3589 counts per minute, which had a corresponding sensitivity and specificity of 88.0% and 98.7%, respectively. This study established intensity-specific cut-points for wrist-based wear of the Actical accelerometer which are recommended for quantification of moderate-and vigorous-intensity ambulatory activity.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [1] Moderate and vigorous physical activity intensity cut-points for the Actical accelerometer
    Colley, Rachel C.
    Tremblay, Mark S.
    JOURNAL OF SPORTS SCIENCES, 2011, 29 (08) : 783 - 789
  • [2] Wrist-based accelerometer cut-points for quantifying moderate-to-vigorous intensity physical activity in Parkinson's disease
    Jeng, Brenda
    Cederberg, Katie L. J.
    Lai, Byron
    Sasaki, Jeffer E.
    Bamman, Marcas M.
    Motl, Robert W.
    GAIT & POSTURE, 2022, 91 : 235 - 239
  • [3] Do moderate- to vigorous-intensity accelerometer count thresholds correspond to relative moderate- to vigorous-intensity physical activity?
    Raiber, Lilian
    Christensen, Rebecca A. G.
    Randhawa, Arshdeep K.
    Jamnik, Veronica K.
    Kuk, Jennifer L.
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2019, 44 (04) : 407 - 413
  • [4] Physical Activity Intensity Cut-Points for Wrist-Worn GENEActiv in Older Adults
    Fraysse, Francois
    Post, Dannielle
    Eston, Roger
    Kasai, Daiki
    Rowlands, Alex V.
    Parfitt, Gaynor
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 2
  • [5] Evaluation of Wrist Accelerometer Cut-Points for Classifying Physical Activity Intensity in Youth
    Trost, Stewart G.
    Brookes, Denise S. K.
    Ahmadi, Matthew N.
    FRONTIERS IN DIGITAL HEALTH, 2022, 4
  • [6] Moderate and Vigorous Physical Activity Intensity Cut-Points for Hip-, Wrist-, Thigh-, and Lower Back Worn Accelerometer in Very Old Adults
    Skjodt, Mathias
    Brond, Jan Christian
    Tully, Mark A.
    Tsai, Li-Tang
    Koster, Annemarie
    Visser, Marjolein
    Caserotti, Paolo
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2025, 35 (01)
  • [7] Wrist-Based Accelerometer Cut-Points to Identify Sedentary Time in 5-11-Year-Old Children
    Chandler, Jessica
    Beets, Michael
    Saint-Maurice, Pedro
    Weaver, Robert
    Cliff, Dylan
    Drenowatz, Clemens
    Moore, Justin B.
    Sui, Xuemei
    Brazendale, Keith
    CHILDREN-BASEL, 2018, 5 (10):
  • [8] Development of cut-points for determining activity intensity from a wrist-worn ActiGraph accelerometer in free-living adults
    Montoye, Alexander H. K.
    Clevenger, Kimberly A.
    Pfeiffer, Karin A.
    Nelson, Michael Benjamin
    Bock, Joshua M.
    Imboden, Mary T.
    Kaminsky, Leonard A.
    JOURNAL OF SPORTS SCIENCES, 2020, 38 (22) : 2569 - 2578
  • [9] Preliminary Investigations of the Validity and Interinstrument Reliability for Classification of Accelerometer Physical Activity Cut-Points Against Indirect Caliometry in Healthy Adults
    McDevitt, Brid
    Connolly, James
    Duddy, Damien
    Doherty, Ronan
    Condell, Joan
    2022 33RD IRISH SIGNALS AND SYSTEMS CONFERENCE (ISSC), 2022,
  • [10] Wrist Acceleration Cut Points for Moderate-to-Vigorous Physical Activity in Youth
    Okely, Anthony D.
    Batterham, Marijka J.
    Hinkley, Trina
    Ekelund, Ulf
    Brage, Soren
    Reilly, John J.
    Trost, Stewart G.
    Jones, Rachel A.
    Janssen, Xanne
    Cliff, Dylan P.
    Van Loo, Christiana Maria Theodora
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (03): : 609 - 616