A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles - Results from a 1-Year Observation Period

被引:106
作者
Al-Nawas, Bilal [1 ]
Bragger, Urs [2 ]
Meijer, Henny J. A. [3 ,4 ]
Naert, Ignace [5 ]
Persson, Rigmor [2 ]
Perucchi, Alessandro [6 ]
Quirynen, Marc [5 ]
Raghoebar, Gerry M. [3 ,4 ]
Reichert, Torsten E. [7 ]
Romeo, Eugenio [8 ]
Santing, Hendrik J. [3 ,4 ]
Schimmel, Martin [9 ]
Storelli, Stefano [8 ]
ten Bruggenkate, Christiaan [10 ]
Vandekerckhove, Betty [5 ]
Wagner, Wilfried [1 ]
Wismeijer, Daniel [10 ]
Mueller, Frauke [9 ]
机构
[1] Johannes Gutenberg Univ Mainz, D-55131 Mainz, Germany
[2] Univ Bern, Sch Dent Med, Bern, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Oral Maxillofacial Surg, NL-9713 AV Groningen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Prosthet Dent, NL-9713 AV Groningen, Netherlands
[5] Catholic Univ Louvain, Sch Dent, B-3000 Louvain, Belgium
[6] Luzerner Kantonsspital, Clin Oral & Maxillofacial Surg, Luzern, Switzerland
[7] Univ Regensburg Clin, Regensburg, Germany
[8] Univ Milan, Dent Clin, San Paolo Hosp, Milan, Italy
[9] Univ Geneva, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[10] Acad Ctr Dent Amsterdam, NL-1066 EA Amsterdam, Netherlands
关键词
alloy; bone level implant; double-blind; edentulous mandible; Locator; RCT; Titanium; Zirconium; FOLLOW-UP; OSSEOINTEGRATED IMPLANTS; ZIRCONIUM ALLOYS; SPLIT-MOUTH; ORAL-HEALTH; OVERDENTURES; SUCCESS;
D O I
10.1111/j.1708-8208.2010.00324.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid (TM)) perform at least as well as Titanium Grade IV implants. Methods and Materials: Patients with an edentulous mandible received one TiZr and one Ti Grade IV small-diameter bone level implant (3.3 mm, SLActive (R)) in the interforaminal region. The site distribution was randomized and double-blinded. Outcome measures included change in radiological peri-implant bone level from surgery to 12 months post-insertion (primary), implant survival, success, soft tissue conditions, and safety (secondary). Results: Of 91 treated patients, 87 were available for the 12-month follow-up. Peri-implant bone level change (-0.3 +/- 0.5 mm vs -0.3 +/- 0.6 mm), plaque, and sulcus bleeding indices were not significantly different between TiZr and Ti Grade IV implants. Implant survival rates were 98.9 percent and 97.8 percent, success rates were 96.6 percent and 94.4 percent, respectively. Nineteen minor and no serious adverse events were related to the study devices. Conclusion: This study confirms that TiZr small-diameter bone level implants provide at least the same outcomes after 12 months as Ti Grade IV bone level implants. The improved mechanical properties of TiZr implants may extend implant therapy to more challenging clinical situations.
引用
收藏
页码:896 / 904
页数:9
相关论文
共 38 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   Astra Tech and Branemark system implants:: a 5-year prospective study of marginal bone reactions [J].
Åstrand, P ;
Engquist, B ;
Dahlgren, S ;
Gröndahl, K ;
Engquist, E ;
Feldmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :413-420
[3]  
Astrand Per, 2002, Clin Implant Dent Relat Res, V4, P115, DOI 10.1111/j.1708-8208.2002.tb00161.x
[4]   Implant-supported fixed prostheses in the edentulous maxilla - A 2-year clinical and radiological follow-up of treatment with non-submerged ITI implants [J].
Bergkvist, G ;
Sahlholm, S ;
Nilner, K ;
Lindh, C .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (03) :351-359
[5]   Patterns of tissue remodeling after placement of ITI® dental implants using an osteotome technique:: a longitudinal radiographic case cohort study [J].
Brägger, U ;
Gerber, C ;
Joss, A ;
Haenni, S ;
Meier, A ;
Hashorva, E ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :158-166
[6]   Use of radiographs in evaluating success, stability and failure in implant dentistry [J].
Bragger, U .
PERIODONTOLOGY 2000, 1998, 17 :77-88
[7]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[8]  
Bulard Ronald A, 2005, Compend Contin Educ Dent, V26, P892
[9]   Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants [J].
Buser, D. ;
Weber, H-P ;
Lang, N. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :33-40
[10]   Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533