Test, modeling, and analysis of air-coupled ultrasonic transducer based on piezoelectret film

被引:3
|
作者
Zhang, Fenglin [1 ]
Pan, Yongdong [1 ]
Zhao, Jinfeng [1 ]
Zhang, Xiaoqing [2 ]
机构
[1] Tongji Univ, Sch Aerosp Engn & Appl Mech, Shanghai 200092, Peoples R China
[2] Tongji Univ, Sch Phys Sci & Engn, Shanghai Key Lab Special Artificial Microstruct M, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
LAMB; FERROELECTRETS; GENERATION; WAVES;
D O I
10.1063/5.0004688
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Piezoelectrets, a new type of electromechanical transducer material with low acoustic impedance and high piezoelectric d(33) and g(33) coefficients, are promising candidates for developing high-performance air-coupled ultrasonic transducers. In this work, we design polypropylene-piezoelectret-film based air-coupled transducers (ACTs) with two different structures and investigate the influence of boundary conditions of the film with experimental measurement, electromechanical equivalent circuit modeling (EECM), and finite element analysis (FEA) for both inverse and direct piezoelectric effects. The experimental data are in great agreement with the results of EECM and FEA. The resonant frequency of the ACT with a free-front-clamped-back (FFCB) film is about half of that of the device with a free-front-free-back (FFFB) film, the response peak of the FFCB device is higher than that of the FFFB device, and the -3dB bandwidth of the former is much narrower than that of the latter. The results show that the experimental measurements can be predicted by EECM and FEA, which can provide the basis for the development of high-performance air-coupled ultrasonic transducers based on piezoelectret films.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Univ of Strathclyde, Glasgow, United Kingdom
    IEEE Trans Ultrason Ferroelectr Freq Control, 6 (1549-1558):
  • [32] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Galbraith, W
    Hayward, G
    Benny, G
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 917 - 920
  • [33] Noncontact photoacoustic angiography with an air-coupled ultrasonic transducer for evaluation of burn injury
    Ma, Haigang
    Xiong, Kedi
    Wu, Junwei
    Ji, Xuanrong
    Yang, Sihua
    APPLIED PHYSICS LETTERS, 2019, 114 (13)
  • [34] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Galbraith, W
    Hayward, G
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (06) : 1549 - 1558
  • [35] Investigation of acoustic field calculation and measurement method for air-coupled ultrasonic transducer
    Kong, Tao
    Xu, Chunguang
    Zhang, Yuntao
    Xu, Hanhui
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (22): : 19 - 24
  • [37] Noise analysis in air-coupled PVDF ultrasonic sensors
    Fiorillo, AS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (06) : 1432 - 1437
  • [38] Design and Fabrication of Air-Based 1-3 Piezoelectric Composite Transducer for Air-Coupled Ultrasonic Applications
    He, Cunfu
    Wang, Yaoyao
    Lu, Yan
    Liu, Yuepeng
    Wu, Bin
    JOURNAL OF SENSORS, 2016, 2016
  • [39] Residual bias phenomenon in air-coupled ultrasonic capacitive film transducers
    Holland, SD
    Song, JH
    Chimenti, DE
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 916 - 921
  • [40] Analysis of Air-Coupled Transducer-Based Elastic Waves Generation in CFRP Plates
    Wandowski, Tomasz
    Mindykowski, Damian
    Kudela, Pawel
    Radzienski, Maciej
    SENSORS, 2021, 21 (21)