Validation of reliability and predictivity of membrane septum length measurements for pacemaker need after transcatheter aortic valve replacement

被引:5
作者
Hioki, Hirofumi [1 ]
Watanabe, Yusuke [1 ]
Kozuma, Ken [1 ]
Ryuzaki, Toshinobu [2 ]
Goto, Shinichi [2 ,3 ,4 ]
Inohara, Taku [2 ]
Katsumata, Yoshinori [2 ]
Tsunaki, Tatsuya [5 ]
Kawahata, Ryotaku [6 ]
Kobayashi, Toshihiro [6 ]
Asami, Masahiko [7 ]
Otsuka, Toshiaki [8 ,9 ]
Yamamoto, Masanori [5 ,6 ]
Hayashida, Kentaro [2 ]
机构
[1] Teikyo Univ Hosp, Div Cardiol, Tokyo, Japan
[2] Keio Univ, Dept Cardiol, Sch Med, Tokyo, Japan
[3] Brigham & Womens Hosp, Dept Med, One Brave Idea, 75 Francis St, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Div Cardiovasc Med, 75 Francis St, Boston, MA 02115 USA
[5] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Aichi, Japan
[6] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Aichi, Japan
[7] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[8] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[9] Nippon Med Coll Hosp, Ctr Clin Res, Tokyo, Japan
关键词
aortic stenosis; atrioventricular block; conduction abnormalities; implantation depth; membrane septum; TAVR; Delta MSID; CONDUCTION DISTURBANCES; ATRIOVENTRICULAR-BLOCK; IMPLANTATION; COREVALVE; DEPTH; RISK; SYSTEM;
D O I
10.1002/ccd.30377
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To assess the inter methodological agreement of membrane septum (MS) length measurement and additive value for risk stratification of new pacemaker implantation (PMI) over the established predictors after transcatheter aortic valve replacement (TAVR). Background: Recent studies have suggested MS length and implantation depth (ID) as predictors for PMI after TAVR. However, the measurement of MS length is neither uniform nor validated in different cohort. Methods: We retrospectively analyzed patients who underwent TAVR at five centers. The MS length was measured by two previously proposed methods (corona) and annular view method). Predictive ability of risk factors, including MS length and ID, for new PMI within 30 days after TAVR were evaluated. Results: Among 754 patients of study population, 31 patients (4.1%) required new PMI within 30 days of TAVR. There was a weak correlation (rho = 0.47) and a poor agreement between the two methods. The ID and the difference between MS length and ID (Delta MSID), were independent predictors for new PMI, whereas MS length alone was not. Further, for predicting new PMI after TAVR, discrimination performance was not significantly improved when MS length was added to the model with ID alone (integrated discrimination improvement = 0, p= 0.99; continuous net-reclassification improvement = 0.10, p= 0.62). Conclusions: External validity and predictive accuracy of MS length for PMI after TAVR were not sufficient to provide better risk stratification over the established predictors in our cohort. Moreover, the ID and Delta MSID, but not MS length alone, are predictive of future PMI after TAVR.
引用
收藏
页码:868 / 876
页数:9
相关论文
共 22 条
[1]   Association of Clinical and Economic Outcomes With Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement [J].
Aljabbary, Talal ;
Qiu, Feng ;
Masih, Shannon ;
Fang, Jiming ;
Elbaz-Greener, Gabby ;
Austin, Peter C. ;
Rodes-Cabau, Josep ;
Ko, Dennis T. ;
Singh, Sheldon ;
Wijeysundera, Harindra C. .
JAMA NETWORK OPEN, 2018, 1 (01) :e180088
[2]   Conduction Disturbances After Transcatheter Aortic Valve Replacement Current Status and Future Perspectives [J].
Auffret, Vincent ;
Puri, Rishi ;
Urena, Marina ;
Chamandi, Chekrallah ;
Rodriguez-Gabella, Tania ;
Philippon, Francois ;
Rodes-Cabau, Josep .
CIRCULATION, 2017, 136 (11) :1049-+
[3]   Coronary Cannulation After Transcatheter Aortic Valve Replacement The RE-ACCESS Study [J].
Barbanti, Marco ;
Costa, Giuliano ;
Picci, Andrea ;
Criscione, Enrico ;
Reddavid, Claudia ;
Valvo, Roberto ;
Todaro, Denise ;
Deste, Wanda ;
Condorelli, Antonio ;
Scalia, Matteo ;
Licciardello, Alessandra ;
Politi, Giorgia ;
De Luca, Giuseppe ;
Strazzieri, Orazio ;
Motta, Silvia ;
Garretto, Valeria ;
Veroux, Pierfrancesco ;
Giaquinta, Alessia ;
Giuffrida, Angelo ;
Sgroi, Carmelo ;
Leon, Martin B. ;
Webb, John G. ;
Tamburino, Corrado .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (21) :2542-2555
[4]   Early Conduction Disorders Following Percutaneous Aortic Valve Replacement [J].
Calvi, Valeria ;
Puzzangara, Euglena ;
Pruiti, Giusi Paola ;
Conti, Sergio ;
Di Grazia, Angelo ;
Ussia, Gian Paolo ;
Capodanno, Davide ;
Tamburino, Corrado .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S126-S130
[5]   Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement [J].
Fovino, Luca Nai ;
Cipriani, Alberto ;
Fabris, Tommaso ;
Massussi, Mauro ;
Scotti, Andrea ;
Lorenzoni, Giulia ;
Guerra, Maria Chiara ;
Cardaioli, Francesco ;
Rodino, Giulio ;
Matsuda, Yuji ;
Masiero, Giulia ;
Leoni, Loira ;
Zorzi, Alessandro ;
Fraccaro, Chiara ;
Tarantini, Giuseppe .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (01) :E009028
[6]   Predictors and Course of High-Degree Atrioventricular Block After Transcatheter Aortic Valve Implantation Using the CoreValve Revalving system [J].
Guetta, Victor ;
Goldenberg, Gustavo ;
Segev, Amit ;
Dvir, Danny ;
Kornowski, Ran ;
Finckelstein, Arik ;
Hay, Ilan ;
Goldenberg, Ilan ;
Glikson, Michael .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (11) :1600-1605
[7]   Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation [J].
Hamdan, Ashraf ;
Guetta, Victor ;
Klempfner, Robert ;
Konen, Eli ;
Raanani, Ehud ;
Glikson, Michael ;
Goitein, Orly ;
Segev, Amit ;
Barbash, Israel ;
Fefer, Paul ;
Spiegelstein, Dan ;
Goldenberg, Ilan ;
Schwammenthal, Ehud .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (09) :1218-1228
[8]   Effect of Serum C-Reactive Protein Level on Admission to Predict Mortality After Transcatheter Aortic Valve Implantation [J].
Hioki, Hirofumi ;
Watanabe, Yusuke ;
Kozuma, Ken ;
Yamamoto, Masanori ;
Naganuma, Toru ;
Araki, Motoharu ;
Tada, Norio ;
Shirai, Shinichi ;
Yamanaka, Futoshi ;
Higashimori, Akihiro ;
Mizutani, Kazuki ;
Tabata, Minoru ;
Takagi, Kensuke ;
Ueno, Hiroshi ;
Hayashida, Kentaro .
AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (02) :294-301
[9]   Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation [J].
Iacovelli, Fortunato ;
Pignatelli, Antonio ;
Giugliano, Giuseppe ;
Stabile, Eugenio ;
Cicala, Mariangela ;
Salemme, Luigi ;
Cioppa, Angelo ;
Popusoi, Grigore ;
Pucciarelli, Armando ;
Verdoliva, Sebastiano ;
Bortone, Alessandro Santo ;
Losi, Maria-Angela ;
Coscioni, Enrico ;
Esposito, Giovanni ;
Contegiacomo, Gaetano ;
Tesorio, Tullio .
EUROPACE, 2018, 20 (01) :116-123
[10]   Delayed Coronary Obstruction After Transcatheter Aortic Valve Replacement [J].
Jabbour, Richard J. ;
Tanaka, Akihito ;
Finkelstein, Ariel ;
Mack, Michael ;
Tamburino, Corrado ;
Van Mieghem, Nicolas ;
de Backer, Ole ;
Testa, Luca ;
Gatto, Pamela ;
Purita, Paola ;
Rahhab, Zouhair ;
Veulemans, Verena ;
Stundl, Anja ;
Barbanti, Marco ;
Nerla, Roberto ;
Sinning, Jan Malte ;
Dvir, Danny ;
Tarantini, Giuseppe ;
Szerlip, Molly ;
Scholtz, Werner ;
Scholtz, Smita ;
Tchetche, Didier ;
Castriota, Fausto ;
Butter, Christian ;
Sondergaard, Lars ;
Abdel-Wahab, Mohamed ;
Sievert, Horst ;
Alfieri, Ottavio ;
Webb, John ;
Rodes-Cabau, Josep ;
Colombo, Antonio ;
Latib, Azeem .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (14) :1513-1524