Smartphone-Based Optofluidic Lab-on-a-Chip for Detecting Pathogens from Blood

被引:34
作者
Stemple, C. Christopher [1 ]
Angus, Scott V. [2 ]
Park, Tu San [2 ]
Yoon, Jeong-Yeol [1 ,2 ]
机构
[1] Univ Arizona, Biomed Engn Grad Interdisciplinary Program, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
来源
JALA | 2014年 / 19卷 / 01期
关键词
cell phone-based detection; Plasmodium falciparum; histidine-rich protein 2; HRP-2; microfluidic; immunoagglutination; Mie scatter; CELL-PHONE; SENSITIVE DETECTION; MALARIA; DIAGNOSIS; CELLPHONE; PLATFORM; SYSTEM;
D O I
10.1177/2211068213498241
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel smartphone-based detection device was created to detect infectious pathogens directly from diluted (10%) human whole blood. The model pathogen was histidine-rich protein 2 (HRP-2), an antigen specific to Plasmodium falciparum (malaria). Anti-HRP-2-conjugated submicrobeads were mixed with HRP-2-infused 10% blood in a lab-on-a-chip device. The white LED flash and the digital camera of the smartphone were used as light source and detector, which delivered light to and from the bead and blood mixture via optofluidic channels in the lab-on-a-chip. The optofluidic channels were angled at 45 degrees to capture the Mie scatter from the sample. Considering the absorption and scattering characteristics of blood (red/infrared preferred) and the Mie scatter simulations for microbead immunoagglutination (UV preferred), blue detection showed the best results. The detection limit was 1 pg/mL in 10% blood. The linear range was from 1 pg/mL to 10 ng/mL. A handheld device, easily attachable to a single smartphone, was finally designed and fabricated using optical mirrors and lenses and successfully detected the HRP-2 from 10% blood. The total assay time was approximately 10 min. The proposed device can potentially be used for detecting a wide range of blood infection with high sensitivity.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 23 条
[1]   Flow Sensing of Single Cell by Graphene Transistor in a Microfluidic Channel [J].
Ang, Priscilla Kailian ;
Li, Ang ;
Jaiswal, Manu ;
Wang, Yu ;
Hou, Han Wei ;
Thong, John T. L. ;
Lim, Chwee Teck ;
Loh, Kian Ping .
NANO LETTERS, 2011, 11 (12) :5240-5246
[2]  
Balk R.A., 2001, Sepsis Handbook
[3]   Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array [J].
Bishara, Waheb ;
Sikora, Uzair ;
Mudanyali, Onur ;
Su, Ting-Wei ;
Yaglidere, Oguzhan ;
Luckhart, Shirley ;
Ozcan, Aydogan .
LAB ON A CHIP, 2011, 11 (07) :1276-1279
[4]  
Canalys, 2011, SMART PHON OV CLIENT
[5]   A personalized food allergen testing platform on a cellphone [J].
Coskun, Ahmet F. ;
Wong, Justin ;
Khodadadi, Delaram ;
Nagi, Richie ;
Tey, Andrew ;
Ozcan, Aydogan .
LAB ON A CHIP, 2013, 13 (04) :636-640
[6]   Simple Fluidic System for Purifying and Concentrating Diagnostic Biomarkers Using Stimuli-Responsive Antibody Conjugates and Membranes [J].
Golden, Allison L. ;
Battrell, Charles F. ;
Pennell, Sean ;
Hoffman, Allan S. ;
Lai, James J. ;
Stayton, Patrick S. .
BIOCONJUGATE CHEMISTRY, 2010, 21 (10) :1820-1826
[7]   Nanoparticle immunoagglutination Rayleigh scatter assay to complement microparticle immunoagglutination Mie scatter assay in a microfluidic device [J].
Heinze, Brian C. ;
Yoon, Jeong-Yeol .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 85 (02) :168-173
[8]   Microfluidic immunosensor with integrated liquid core waveguides for sensitive Mie scattering detection of avian influenza antigens in a real biological matrix [J].
Heinze, Brian C. ;
Gamboa, Jessica R. ;
Kim, Keesung ;
Song, Jae-Young ;
Yoon, Jeong-Yeol .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (06) :2693-2700
[9]   A microfluidic system to study cytoadhesion of Plasmodium falciparum infected erythrocytes to primary brain microvascularendothelial cells [J].
Herricks, Thurston ;
Seydel, Karl B. ;
Turner, George ;
Molyneux, Malcolm ;
Heyderman, Robert ;
Taylor, Terrie ;
Rathod, Pradipsinh K. .
LAB ON A CHIP, 2011, 11 (17) :2994-3000
[10]   Rapid diagnosis of malaria [J].
Kakkilaya, BS .