HbA1c response and hospital admissions following commencement of flash glucose monitoring in adults with type 1 diabetes

被引:11
|
作者
Stimson, Roland H. [1 ]
Dover, Anna R. [2 ]
Ritchie, Stuart A. [3 ]
Wright, Rohana J. [4 ]
McKnight, John A. [3 ]
Zammitt, Nicola N. [2 ]
Gibb, Fraser W. [1 ,2 ]
机构
[1] Univ Edinburgh, Queens Med Res Inst, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Royal Infirm Edinburgh NHS Trust, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[3] Western Gen Hosp, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[4] NHS Lothian, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
关键词
A1c; continous blood glucose monitor(s); hypoglycemia; ketoacidosis; QUALITY-OF-LIFE; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; PEOPLE;
D O I
10.1136/bmjdrc-2020-001292
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Our aim was to assess the effect of introducing flash monitoring in adults with type 1 diabetes with respect to change in hemoglobin A1c (HbA1c) and frequency of hospital admissions. Research design and methods Prospective observational study of adults with type 1 diabetes in our center, in whom a prescription for a flash monitoring sensor was collected. Primary outcome was change in HbA1c between 2016 and after flash monitoring. Rates of hospital admission were compared between the first year after flash monitoring and the corresponding 12-month period 2 years earlier. Results Approximately half of all adults with type 1 diabetes, attending our center, collected prescriptions for flash monitoring sensors (n=2216). Median fall in HbA1c was -1 (-0.1) mmol/mol (%) (p<0.001) and was greatest in those with baseline HbA1c >75 (9.0) mmol/mol (%): -10 (-0.9) mmol/mol (%), p53 mmol/mol (7%) experienced a >= 5 mmol/mol (0.5%) fall in HbA1c. In addition to higher HbA1c, early commencement within 1 month of NHS-funded flash monitoring (p<0.001), and male gender (p=0.013) were associated with a fall in HbA1c of >= 5 (0.5) mmol/mol (%). Socioeconomic deprivation (p=0.009) and collecting fewer than 2 sensors per month (p=0.002) were associated with lack of response. Overall, hospital admissions did not change but an increase in admissions for hypoglycemia was observed (1.1% vs 0.3%, p=0.026). Conclusions Flash monitoring is associated with reduction in HbA1c in individuals with HbA1c >58 mmol/mol. Numerous clinical features are independently associated with HbA1c response. An increase in hypoglycemia admissions occurred following flash monitoring.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes
    Tyndall, Victoria
    Stimson, Roland H.
    Zammitt, Nicola N.
    Ritchie, Stuart A.
    McKnight, John A.
    Dover, Anna R.
    Gibb, Fraser W.
    DIABETOLOGIA, 2019, 62 (08) : 1349 - 1356
  • [2] HbA1c reduction following flash monitoring commencement is not independently associated with adverse diabetic eye disease outcomes in type 1 diabetes
    Al-Dalla Ali, Muhammad
    Stimson, Roland H.
    Dover, Anna R.
    Forbes, Shareen
    Annoh, Roxanne
    Madill, Karen
    Gibb, Fraser W.
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (02)
  • [3] HbA1c Is Disproportionately Higher in Women and Older People With Type 1 Diabetes Compared With Flash Glucose Monitoring Metrics of Glycemic Control
    Stimson, Roland H.
    Dover, Anna R.
    Forbes, Shareen
    Strachan, Mark W. J.
    McKnight, John A.
    Gibb, Fraser W.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02): : 446 - 453
  • [4] Can HbA1c detect undiagnosed diabetes in acute medical hospital admissions?
    Manley, Susan E.
    O'Brien, Kathleen T.
    Quinlan, Diarmuid
    Round, Rachel A.
    Nightingale, Peter G.
    Ali, Fauzi
    Durrani, Behram K.
    Liew, Aaron
    Luzio, Stephen D.
    Stratton, Irene M.
    Roberts, Graham A.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 115 : 106 - 114
  • [5] The interrelationship of HbA1c and real-time continuous glucose monitoring in children with type 1 diabetes
    Ferenci, Tamas
    Koerner, Anna
    Kovacs, Levente
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (01) : 38 - 44
  • [6] The importance of HbA1c and glucose variability in patients with type 1 and type 2 diabetes: outcome of continuous glucose monitoring (CGM)
    Sartore, Giovanni
    Chilelli, Nino Cristiano
    Burlina, Silvia
    Di Stefano, Paola
    Piarulli, Francesco
    Fedele, Domenico
    Mosca, Andrea
    Lapolla, Annunziata
    ACTA DIABETOLOGICA, 2012, 49 : S153 - S160
  • [7] Improving HbA1c Control in Type 1 or Type 2 Diabetes Using Flash Glucose Monitoring: A Retrospective Observational Analysis in Two German Centres
    Ludger Rose
    Gerhard Klausmann
    Alexander Seibold
    Diabetes Therapy, 2021, 12 : 363 - 372
  • [8] Improving HbA1c Control in Type 1 or Type 2 Diabetes Using Flash Glucose Monitoring: A Retrospective Observational Analysis in Two German Centres
    Rose, Ludger
    Klausmann, Gerhard
    Seibold, Alexander
    DIABETES THERAPY, 2021, 12 (01) : 363 - 372
  • [9] Determination of Glucose-Independent Racial Disparity in HbA1c for Youth With Type 1 Diabetes in the Era of Continuous Glucose Monitoring
    Christakis, Nicholas J.
    Gioe, Marcella
    Gomez, Ricardo
    Felipe, Dania
    Soros, Arlette
    Mccarter, Robert
    Chalew, Stuart
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025, 19 (01): : 72 - 79
  • [10] Snap diagnosis of fulminant type 1 diabetes by the normalized glucose/HbA1c ratio
    Mori, Jun-Ichiro
    Miyakoshi, Takahiro
    Yuzuriha, Hanae
    Kondo, Teruki
    Nishimori, Eita
    Naka, Motoji
    Sato, Ai
    Komatsu, Mitsuhisa
    Yamashita, Koh
    Aizawa, Toru
    ENDOCRINE JOURNAL, 2024, 71 (11) : 1093 - 1096