Maximum Drag Reduction Asymptote for Surfactant-Based Fluids in Circular Coiled Tubing

被引:13
|
作者
Kamel, Ahmed H. [1 ]
Shah, Subhash N. [2 ]
机构
[1] Univ Texas Permian Basin, Sch Business, Odessa, TX 79762 USA
[2] Univ Oklahoma, Mewbourne Sch Petr & Geol Engn, Sarkeys Energy Ctr T301, Norman, OK 73019 USA
来源
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME | 2013年 / 135卷 / 03期
关键词
surfactant; straight tubing; coiled tubing; friction factor; drag reduction; MDR asymptote; FRICTION-FACTOR; FLOW; PIPES;
D O I
10.1115/1.4023297
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Surfactants are superior to polymers in reducing drag and their advantages are very well established. As drag reducers, several factors, such as concentration, temperature, salinity, shear rate, etc., can affect their behavior. Other unique factors relevant to surfactants may include tubing diameter (scale-up effect), head group structure, counterion, charge, etc. Although, drag reduction envelope is customarily employed to investigate drag reduction phenomena, it is defined only for polymeric fluids in both straight and coiled tubing and for surfactant-based (SB) fluids in straight tubing. No such envelope is available for SB fluids in coiled tubing. The present research aims at experimentally investigating the drag reduction characteristics of the most widely used Aromox APA-T surfactant-based fluids. It is a highly active surfactant used as gelling agent in aqueous and brine base fluids. Flow data are gathered using small and large scale flow loops. Straight and coiled tubing with various sizes (1.27 cm to 7.30 cm o.d.) and curvature ratios (0.01 to 0.031) covering the field application range are utilized. The results show that SB fluids exhibit superior drag reduction characteristics. Their behavior is significantly affected by surfactant concentration, shear, tubing size, and geometry. Higher drag reduction is seen in straight tubing than in coiled tubing and increasing curvature ratio yields higher friction pressure losses. In coiled tubing, SB fluids exhibit better drag reduction characteristics than Shah and Zhou maximum drag reduction (MDR) asymptote for polymeric fluids. Therefore, a new maximum drag reduction asymptote is developed using data gathered in 1.27 cm o.d. tubing. The proposed correlation agrees with Zakin MDR asymptote for SB fluids in straight tubing where the curvature ratio is set to be zero. Employing the proposed correlation, a modified drag reduction envelope can be used to evaluate drag reduction characteristics of SB fluids.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Maximum Drag Reduction Asymptote of Polymeric Fluid Flow in Coiled Tubing
    Shah, Subhash N.
    Zhou, Yunxu
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (01): : 0112011 - 0112019
  • [2] Scale-Up Correlation for the Flow of Surfactant-Based Fluids in Circular Coiled Pipes
    Kamel, Ahmed H. Ahmed
    Shah, Subhash N.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (08):
  • [3] Effects of coiled-tubing curvature on drag reduction of polymeric fluids
    Zhou, Y.
    Shah, S. N.
    Gujar, P. V.
    SPE PRODUCTION & OPERATIONS, 2006, 21 (01): : 134 - 141
  • [4] Investigation of the Complex Flow Behaviour of Surfactant-Based Fluids in Straight Tubing
    Kamel, A. H. Ahmed
    Shah, S. N.
    JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 2010, 49 (06): : 13 - 20
  • [5] Theory of concentration dependence in drag reduction by polymers and of the maximum drag reduction asymptote
    Benzi, R
    Ching, ESC
    Horesh, N
    Procaccia, I
    PHYSICAL REVIEW LETTERS, 2004, 92 (07)
  • [6] The onset of drag reduction by dilute polymer additives, and the maximum drag reduction asymptote
    Sreenivasan, KR
    White, CM
    JOURNAL OF FLUID MECHANICS, 2000, 409 : 149 - 164
  • [7] Effects of solids loading on drag reduction in polymeric drilling fluids through straight and coiled tubing
    Shah, SN
    Tareen, M
    Clark, D
    JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 2002, 41 (05): : 63 - 69
  • [8] Limiting maximum drag-reduction asymptote for the moment coefficient of a rotating disk in drag-reducing surfactant solution
    Ogata, S
    Watanabe, K
    JOURNAL OF FLUID MECHANICS, 2002, 457 : 325 - 337
  • [9] Drag reduction characteristics in straight and coiled tubing - An experimental study
    Shah, Subhash N.
    Kamel, Ahmed
    Zhou, Yunxu
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2006, 53 (3-4) : 179 - 188
  • [10] An experimental study of drag reduction of polymer solutions in coiled tubing
    Shah, SN
    Zhou, Y
    SPE PRODUCTION & FACILITIES, 2003, 18 (04): : 280 - 287