Improvement of the sensor system in magnetic flux leakage-type nondestructive testing (NDT)

被引:3
|
作者
Park, GS [1 ]
Park, ES [1 ]
机构
[1] Korea Maritime Univ, Dept Elect Engn, Pusan 606791, South Korea
关键词
magnetic flux leakage (MFL); magnetic sensor; nondestructive testing (NDT); nonlinear finite-element analysis;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In magnetic flux leakage (MFL)-type nondestructive testing (NDT) system, the sensitivity of MFL sensor depends on the change of the magnetic field, not just on the magnitude of the field. In this paper, the leakage parameter was defined to determine the operating point in saturation curves, and an optimum design method to determine the size of the magnet to maximize the MFL signals in NDT is described. For detecting the small depth defect, we also developed the back yoke sensor system. The sensitivity of the optimum sensor system is increased up to 200%. The computed MFL signals in the optimally designed system are verified by measurement using Hall sensors mounted on the six-legged PIG in an 8-in test pipe with defects. The rhombic defects could be successfully measured and identified from the weak defect signals.
引用
收藏
页码:1277 / 1280
页数:4
相关论文
共 50 条
  • [1] Improvement of the sensor system in magnetic flux leakage-type nondestructive testing (NDT)
    Park, Gwan Soo
    Park, Eun Sik
    IEEE Transactions on Magnetics, 2002, 38 (2 I) : 1277 - 1280
  • [2] The Application of Topological Gradients to Defect Identification in Magnetic Flux Leakage-Type NDT
    Li, M.
    Lowther, D. A.
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (08) : 3221 - 3224
  • [3] FEM modelling techniques of magnetic flux leakage-type NDT for ferromagnetic plate inspections
    Al-Naemi, F. I.
    Hall, J. P.
    Moses, A. J.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2006, 304 (02) : E790 - E793
  • [4] Magnetic mechanisms of magnetic flux leakage nondestructive testing
    Sun, Yanhua
    Kang, Yihua
    APPLIED PHYSICS LETTERS, 2013, 103 (18)
  • [5] A Review of Magnetic Flux Leakage Nondestructive Testing
    Feng, Bo
    Wu, Jianbo
    Tu, Hongming
    Tang, Jian
    Kang, Yihua
    MATERIALS, 2022, 15 (20)
  • [6] Influence of Specimen Velocity on the Leakage Signal in Magnetic Flux Leakage Type Nondestructive Testing
    Zhang, Lintao
    Belblidia, Fawzi
    Cameron, Ian
    Sienz, Johann
    Boat, Matthew
    Pearson, Neil
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2015, 34 (02)
  • [7] Influence of Specimen Velocity on the Leakage Signal in Magnetic Flux Leakage Type Nondestructive Testing
    Lintao Zhang
    Fawzi Belblidia
    Ian Cameron
    Johann Sienz
    Matthew Boat
    Neil Pearson
    Journal of Nondestructive Evaluation, 2015, 34
  • [8] Multi-Objective Optimization of a Magnetic Circuit for Magnetic Flux Leakage-Type Non-destructive Testing
    Parra-Raad, Jaime A.
    Roa-Prada, Sebastian
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2016, 35 (01) : 1 - 12
  • [9] Multi-Objective Optimization of a Magnetic Circuit for Magnetic Flux Leakage-Type Non-destructive Testing
    Jaime A. Parra-Raad
    Sebastián Roa-Prada
    Journal of Nondestructive Evaluation, 2016, 35
  • [10] A Giant-Magnetoresistance Sensor for Magnetic-Flux-Leakage Nondestructive Testing of a Pipeline
    L. Chen
    P.-W. Que
    T. Jin
    Russian Journal of Nondestructive Testing, 2005, 41 : 462 - 465