Impact of vessel curvature on neointimal healing after stent implantation as assessed by optical coherence tomography

被引:3
|
作者
Fu, Yandong [1 ]
Zhang, Shaotao [1 ]
Du, Hongwei [1 ]
Li, Lulu [1 ]
Wang, Chao [1 ]
Zheng, Gonghui [1 ]
Wang, Yan [1 ]
Dong, Hui [1 ]
Jia, Haibo [1 ]
Yu, Bo [1 ]
机构
[1] Harbin Med Univ, Dept Cardiol, Affiliated Hosp 2, Harbin, Heilongjiang, Peoples R China
关键词
neointimal healing; optical coherence tomography; vessel curvature; ENDOTHELIAL SHEAR-STRESS; CORONARY-ARTERY-DISEASE; ELUTING STENT; FOLLOW-UP; RESTENOSIS; COVERAGE; WALL; PLAQUE; PROGRESSION; CORRELATE;
D O I
10.1097/MD.0000000000010518
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose:Previous studies have indicated that stent implantation could alter the vessel geometry, which may impact the neointimal healing process. Curvature is an important parameter for evaluating vessel geometry. The purpose of our study was to investigate the relationship between vessel curvature and neointimal healing after stent implantation. Methods:Fifty-nine patients with acute coronary syndrome (ACS) who underwent stent implantation were enrolled in the study. According to the post-percutaneous coronary intervention vessel curvature measured by quantitative coronary angiography, patients were divided into high (n=30) and low (n=29) curvature groups. Neointimal thickness and area together with the neointimal type were assessed by optical coherence tomography at a 6-month follow-up. Results:Baseline clinical characteristics were comparable between the 2 groups. The vessel curvature at pre- and 6-month follow-up was significantly higher in the high curvature group than the low curvature group. At 6-month follow-up, neointimal thickness (0.22 [0.08-0.32] mm vs. 0.10 [0.07-0.16] mm, P=.043) and neointimal area (1.86 [0.66-2.66] vs. 0.82 [0.60-1.41] mm(2), P=.030) were significantly higher in the high curvature group than the low curvature group. In the high curvature group, the incidence of the heterogeneous neointimal type was higher than that in the low curvature group (50.00% vs. 17.20%, respectively, P=.004), whereas the frequency of the homogeneous neointimal type was lower (43.30% vs. 82.80%, respectively, P=.004) in the high curvature group than the low curvature group. Conclusion:Higher vessel curvature after stent implantation may potentially have an impact on the neointimal healing with a higher incidence of heterogeneous neointimal.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Stent implantation and vascular healing of a spontaneous coronary artery dissection assessed by optical coherence tomography in a patient with acute coronary syndrome
    Hansen, Kirstine Norregaard
    Antonsen, Lisbeth
    Jensen, Lisette Okkels
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (03) : 376 - 379
  • [32] Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels
    Nakamura, Shun
    Kimura, Shigeki
    Nakagama, Shun
    Misawa, Toru
    Mizusawa, Masafumi
    Hayasaka, Kazuto
    Yamakami, Yosuke
    Kojima, Keisuke
    Sagawa, Yuichiro
    Hishikari, Keiichi
    Hikita, Hiroyuki
    Takahashi, Atsushi
    Hirao, Kenzo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (12) : 2147 - 2155
  • [33] Natural history of low-intensity neointimal tissue after an everolimus-eluting stent implantation: a serial observation with optical coherence tomography
    Masahiko Shibuya
    Kenichi Fujii
    Masashi Fukunaga
    Takahiro Imanaka
    Kojiro Miki
    Hiroto Tamaru
    Mitsumasa Ohyanagi
    Tohru Masuyama
    Heart and Vessels, 2015, 30 : 136 - 139
  • [34] Effects of angiotensin receptor blockers on neointimal characteristics in angina patients requiring stent implantation: optical coherence tomography analysis
    Cho, Jae Young
    Hong, Soon Jun
    Lim, Do-Sun
    BMC CARDIOVASCULAR DISORDERS, 2017, 17
  • [35] Coronary Stent Healing in Cancer Patients-An Optical Coherence Tomography Perspective
    Aziz, Moez Karim
    Herrmann, Joerg
    Marmagkiolis, Konstantinos
    Balanescu, Dinu Valentin
    Donisan, Teodora
    Pushparaji, Bala
    Lin, Heather Y.
    Tomakin, Gerryross
    Hoyt, Taylor
    Pham, Martin
    Dijkstra, Jouke
    Cilingiroglu, Mehmet
    Lopez-Mattei, Juan
    Zaha, Vlad
    Anderson, H. Vernon
    Feldman, Marc D.
    Molony, Donald A.
    Iliescu, Cezar A.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [36] Plaque Erosion Delays Vascular Healing After Drug Eluting Stent Implantation in Patients with Acute Coronary Syndrome: An In Vivo Optical Coherence Tomography Study
    Hu, Sining
    Wang, Chao
    Zhe, Chunyang
    Zhu, Yinchun
    Yonetsu, Taishi
    Jia, Haibo
    Hou, Jingbo
    Zhang, Shaosong
    Jang, Ik-Kyung
    Yu, Bo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 : 592 - 600
  • [37] Impact of Coronary Plaque Morphology Assessed by Optical Coherence Tomography on Cardiac Troponin Elevation in Patients With Elective Stent Implantation
    Lee, Tetsumin
    Yonetsu, Taishi
    Koura, Kenji
    Hishikari, Keiichi
    Murai, Tadashi
    Iwai, Toshiyuki
    Takagi, Takamitsu
    Iesaka, Yoshito
    Fujiwara, Hideomi
    Isobe, Mitsuaki
    Kakuta, Tsunekazu
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (04) : 378 - 386
  • [38] Relationship between endothelial vasomotor function and strut coverage after implantation of drug-eluting stent assessed by optical coherence tomography
    Won, Hoyoun
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02) : 263 - 270
  • [39] Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation
    Tamaru, Hiroto
    Fujii, Kenichi
    Nakata, Tsuyoshi
    Fukunaga, Masashi
    Imanaka, Takahiro
    Kawai, Kenji
    Miki, Kojiro
    Horimatsu, Tetsuo
    Nishimura, Machiko
    Saita, Ten
    Sumiyoshi, Akinori
    Shibuya, Masahiko
    Naito, Yoshiro
    Masuyama, Tohru
    Ishihara, Masaharu
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2019, 34 (02) : 164 - 170
  • [40] Impact of coronary calcifications 12 months after everolimus-eluting stent implantation: an optical coherence tomography study
    Zhan, Yefei
    Hou, Jingbo
    Xing, Lei
    Zhang, Yingying
    Yu, Huai
    Yu, Bo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2015, 17 (0F) : F24 - F31