Impact of vessel curvature on neointimal healing after stent implantation as assessed by optical coherence tomography

被引:3
|
作者
Fu, Yandong [1 ]
Zhang, Shaotao [1 ]
Du, Hongwei [1 ]
Li, Lulu [1 ]
Wang, Chao [1 ]
Zheng, Gonghui [1 ]
Wang, Yan [1 ]
Dong, Hui [1 ]
Jia, Haibo [1 ]
Yu, Bo [1 ]
机构
[1] Harbin Med Univ, Dept Cardiol, Affiliated Hosp 2, Harbin, Heilongjiang, Peoples R China
关键词
neointimal healing; optical coherence tomography; vessel curvature; ENDOTHELIAL SHEAR-STRESS; CORONARY-ARTERY-DISEASE; ELUTING STENT; FOLLOW-UP; RESTENOSIS; COVERAGE; WALL; PLAQUE; PROGRESSION; CORRELATE;
D O I
10.1097/MD.0000000000010518
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose:Previous studies have indicated that stent implantation could alter the vessel geometry, which may impact the neointimal healing process. Curvature is an important parameter for evaluating vessel geometry. The purpose of our study was to investigate the relationship between vessel curvature and neointimal healing after stent implantation. Methods:Fifty-nine patients with acute coronary syndrome (ACS) who underwent stent implantation were enrolled in the study. According to the post-percutaneous coronary intervention vessel curvature measured by quantitative coronary angiography, patients were divided into high (n=30) and low (n=29) curvature groups. Neointimal thickness and area together with the neointimal type were assessed by optical coherence tomography at a 6-month follow-up. Results:Baseline clinical characteristics were comparable between the 2 groups. The vessel curvature at pre- and 6-month follow-up was significantly higher in the high curvature group than the low curvature group. At 6-month follow-up, neointimal thickness (0.22 [0.08-0.32] mm vs. 0.10 [0.07-0.16] mm, P=.043) and neointimal area (1.86 [0.66-2.66] vs. 0.82 [0.60-1.41] mm(2), P=.030) were significantly higher in the high curvature group than the low curvature group. In the high curvature group, the incidence of the heterogeneous neointimal type was higher than that in the low curvature group (50.00% vs. 17.20%, respectively, P=.004), whereas the frequency of the homogeneous neointimal type was lower (43.30% vs. 82.80%, respectively, P=.004) in the high curvature group than the low curvature group. Conclusion:Higher vessel curvature after stent implantation may potentially have an impact on the neointimal healing with a higher incidence of heterogeneous neointimal.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Vascular Responses in Patients With and Without Diabetes Mellitus After Everolimus-Eluting Stent Implantation - Optical Coherence Tomography Study
    Iwasaki, Masamichi
    Otake, Hiromasa
    Shinke, Toshiro
    Nakagawa, Masayuki
    Hariki, Hirotoshi
    Osue, Tsuyoshi
    Inoue, Takumi
    Taniguchi, Yu
    Nishio, Ryo
    Kinutani, Hiroto
    Konishi, Akihide
    Hiranuma, Noritoshi
    Kuroda, Masaru
    Shite, Junya
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2014, 78 (09) : 2188 - U294
  • [22] Association of Neointimal Morphology by Optical Coherence Tomography with Rupture of Neoatherosclerotic Plaque Very Late After Coronary Stent Implantation.
    Karanasos, Antonios
    Ligthart, Jurgen
    Witberg, Karen
    Toutouzas, Konstantinos
    Daemen, Joost
    van Soest, Gijs
    Gnanadesigan, Muthukaruppan
    van Geuns, Robert-Jan
    de Jaegere, Peter
    Regar, Evelyn
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [23] Effects of daily glucose fluctuations on the healing response to everolimus-eluting stent implantation as assessed using continuous glucose monitoring and optical coherence tomography
    Kuroda, Masaru
    Shinke, Toshiro
    Otake, Hiromasa
    Sugiyama, Daisuke
    Takaya, Tomofumi
    Takahashi, Hachidai
    Terashita, Daisuke
    Uzu, Kenzo
    Tahara, Natsuko
    Kashiwagi, Daiji
    Kuroda, Koji
    Shinkura, Yuto
    Nagasawa, Yoshinori
    Sakaguchi, Kazuhiko
    Hirota, Yushi
    Ogawa, Wataru
    Hirata, Ken-ichi
    CARDIOVASCULAR DIABETOLOGY, 2016, 15
  • [24] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Ko, Young-Guk
    Kim, Dong-Min
    Cho, Jin Man
    Choi, So Yeon
    Yoon, Jung Han
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 715 - 723
  • [25] Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography
    Malle, Caroline
    Tada, Tomohisa
    Steigerwald, Kristin
    Ughi, Giovanni J.
    Schuster, Tibor
    Nakano, Masataka
    Massberg, Steffen
    Jehle, Johannes
    Guagliumi, Giulio
    Kastrati, Adnan
    Virmani, Renu
    Byrne, Robert A.
    Joner, Michael
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2013, 33 (06) : 1376 - +
  • [26] Impacts of lesion angle on incidence and distribution of acute vessel wall injuries and strut malapposition after drug-eluting stent implantation assessed by optical coherence tomography
    Minami, Yoshiyasu
    Ong, Daniel S.
    Uemura, Shiro
    Wang, Zhao
    Aguirre, Aaron D.
    Mukhopadhyay, Shankha
    Soeda, Tsunenari
    Vergallo, Rocco
    Jia, Haibo
    Tian, Jinwei
    Hu, Sining
    Kim, Soo Joong
    Park, Chang-Bum
    Dauerman, Harold L.
    Lee, Stephen
    Jang, Ik-Kyung
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (12) : 1390 - 1398
  • [27] Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation
    Fu, Qiang
    Hu, Hongyu
    Chen, Wei
    Tan, Zhixu
    Li, Li
    Wang, Dezhao
    Chen, Buxing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2015, 8 (09): : 11068 - 11075
  • [28] "Baumkuchen" Structure Assessed by Optical Coherence Tomography After 15 Years of Bare-Metal Stent Implantation
    Yukimitsu, Nozomu
    Hioki, Hirofumi
    Kyono, Hiroyuki
    Nagura, Fukuko
    Kozuma, Ken
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (23) : 2431 - 2432
  • [29] Healing and early stent coverage after ultrathin strut biodegradable polymer-coated sirolimus-eluting stent implantation: SiBi optical coherence tomography study
    Abhyankar, Atul
    Abizaid, Alexandre
    Chamie, Daniel
    Patel, Gaurang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (07) : 1335 - 1342
  • [30] Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage
    Nam, Hyeong Soo
    Kim, Chang-Soo
    Lee, Jae Joong
    Song, Joon Woo
    Kim, Jin Won
    Yoo, Hongki
    MEDICAL PHYSICS, 2016, 43 (04) : 1662 - 1675