Optimization of retrospective respiratory-gated high speed micro-CT for free-breathing mice

被引:1
作者
Ford, Nancy L. [1 ]
Detombe, Sarah [1 ]
Wheatley, Andrew [1 ]
Holdsworth, David W. [1 ,2 ,3 ]
Drangova, Maria [1 ,2 ,3 ]
机构
[1] John P Robarts Res Inst, Imaging Res Labs, POB 5015, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N64 5B8, Canada
[3] Univ Western Ontario, Diagnost Radiol & Nucl Med, London, ON N64 5B8, Canada
来源
MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2 | 2006年 / 6143卷
基金
加拿大健康研究院;
关键词
volume micro-computed tomography; retrospective respiratory gating; optimization; small-animal imaging; lung physiology;
D O I
10.1117/12.653993
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Technological advances in micro-CT scanners have introduced dynamic, flat-panel scanners, which allow the acquisition of volume images in a few seconds. However, motion artefacts associated with normal respiratory motion arise when imaging the thorax or abdomen. To reduce these artefacts, and the accompanying loss of spatial resolution, and to enable the study of rodent respiratory function, we developed a retrospective respiratory gating technique for volume micro-CT imaging of free-breathing rodents. Anaesthetized male C57BL6 mice were placed in the prone position on a custom-made bed containing an embedded pressure chamber that was connected to a pressure transducer. Inhalation motion caused an increase in the chamber pressure, which was monitored as a surrogate for the respiratory waveform, and measured throughout the scan. Projection images of the mouse thorax were acquired using a GE Locus Ultra micro-CT scanner, at 80 kVp, 50 mA (entrance exposure of approximately 2.7 cGy per rotation), over ten rotations in less than 1 minute. Respiratory gating was performed retrospectively by selecting projections that were obtained during the same portion of the respiratory cycle prior to reconstruction; CT images reconstructed from three to ten rotations were evaluated. The nominal voxel spacing was 0.15 mm. isotropic. Images were assessed for image noise, artefacts and measurement accuracy of physiologically relevant structures. These measurements showed no significant differences for images reconstructed from projection images from five to ten rotations. The optimum number of rotations for imaging mouse lungs was found to be six, corresponding to a 3 0 second (16.2 cGy) scan.
引用
收藏
页数:8
相关论文
共 11 条
[1]   Micro-CT with respiratory and cardiac gating [J].
Badea, C ;
Hedlund, LW ;
Johnson, GA .
MEDICAL PHYSICS, 2004, 31 (12) :3324-3329
[2]   A method of endotracheal intubation and pulmonary functional assessment for repeated studies in mice [J].
Brown, RH ;
Walters, DM ;
Greenberg, RS ;
Mitzner, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2362-2365
[3]   Murine lung tumor measurement using respiratory-gated micro-computed tomography [J].
Cody, DD ;
Nelson, CL ;
Bradley, WM ;
Wislez, M ;
Juroske, D ;
Price, RE ;
Zhou, X ;
Bekele, BN ;
Kurie, JM .
INVESTIGATIVE RADIOLOGY, 2005, 40 (05) :263-269
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   Prospective respiratory-gated micro-CT of free breathing rodents [J].
Ford, NL ;
Nikolov, HN ;
Norley, CJD ;
Thornton, MM ;
Foster, PJ ;
Drangova, M ;
Holdsworth, DW .
MEDICAL PHYSICS, 2005, 32 (09) :2888-2898
[6]   Micro-CT in small animal and specimen imaging [J].
Holdsworth, David W. ;
Thornton, Michael M. .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) :S34-S39
[7]   Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography [J].
Hu, JC ;
Haworth, ST ;
Molthen, RC ;
Dawson, CA .
ACADEMIC RADIOLOGY, 2004, 11 (09) :961-970
[8]   High resolution computed tomography and MRI for monitoring lung tumor growth in mice undergoing radioimmunotherapy: Correlation with histology [J].
Kennel, SJ ;
Davis, IA ;
Branning, J ;
Pan, HJ ;
Kabalka, GW ;
Paulus, MJ .
MEDICAL PHYSICS, 2000, 27 (05) :1101-1107
[9]   Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis [J].
Kiessling, F ;
Greschus, S ;
Lichy, MP ;
Bock, M ;
Fink, C ;
Vosseler, S ;
Moll, J ;
Mueller, MM ;
Fusenig, NE ;
Traupe, H ;
Semmler, W .
NATURE MEDICINE, 2004, 10 (10) :1133-1138
[10]  
Paulus MJ, 2001, LAB ANIMAL, V30, P36