Minimisation of life cycle cost of a detached house using combined simulation and optimisation

被引:145
作者
Hasan, Ala [1 ]
Vuolle, Mika [1 ]
Siren, Kai [1 ]
机构
[1] Helsinki Univ Technol, Lab Heating Ventilating & Air Conditioning, FIN-02015 Espoo, Finland
关键词
Simulation; Optimisation; Life cycle cost; Heating;
D O I
10.1016/j.buildenv.2007.12.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the current study, minimisation of life cycle cost (LCC) for a single family detached house is achieved by combined simulation and optimisation. The house has a typical Finnish construction with initial U-values in accordance with the Finnish National Building Code C3 of 2003. The implemented approach is coupling the IDA ICE 3.0 building performance simulation program with the GenOpt 2.0 generic optimisation program to find optimised values of five selected design variables in the building construction and HVAC system. These variables are three Continuous variables (insulation thickness of the external wall, roof and floor) and two discrete variables (U-value of the windows and type of beat recovery). This investigation shows the advantages gained from the implemented approach of combining simulation and optimisation. The solution suggests lowering the U-values for the external wall, roof, floor and the window from their initial values. The exact values of the optimised design variables depend on the set tip of the LCC data for each case. Reduction of 23-49% in the space heating energy for the optimised house is obtained compared with the reference case. Verification of the GenOpt results is made by comparison with results from a brute-force search method, which indicates that GenOpt has found, or has come very close to, the global minimum in the current study. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2022 / 2034
页数:13
相关论文
共 14 条
[1]  
Achermann M., 2003, RADTEST RADIANT COOL
[2]  
[Anonymous], TRANS SYST SIM PROGR
[3]  
[Anonymous], 2005, IBPSA 2005 INT BUILD
[4]  
Crawley DB, 2000, ASHRAE J, V42, P49
[5]   Optimization of energy consumption in buildings with hydronic heating systems considering thermal comfort by use of computer-based tools [J].
Djuric, Natasa ;
Novakovic, Vojislav ;
Holst, Johnny ;
Mitrovic, Zoran .
ENERGY AND BUILDINGS, 2007, 39 (04) :471-477
[6]  
Fuller S., 1996, NIST Handbook, V135
[7]  
Holst J, 2003, P 8 IBPSA C EINDH NE, P507
[8]  
*MIN TRAD IND, 2005, EN REV
[9]   Whole-building simulation with symbolic DAE equations and general purpose solvers [J].
Sahlin, P ;
Eriksson, L ;
Groman, P ;
Johnsson, H ;
Shapovalov, A ;
Vuolle, M .
BUILDING AND ENVIRONMENT, 2004, 39 (08) :949-958
[10]  
SARJA A, 2003, TIEDOTTEITA2206 TECH