Two autopsy cases of rupture of the aorta by fistula formation after thoracic endovascular aortic repair and open stent-grafting on aortic arch aneurysm

被引:3
作者
Mori, Shinjiro [1 ,2 ]
Kimura, Satoko [1 ]
Ro, Ayako [1 ,3 ]
Hayakawa, Akira [1 ,4 ]
Funakoshi, Izumi [1 ]
Fukunaga, Tatsushige [1 ]
Mizukami, Hajime [1 ,2 ]
机构
[1] Tokyo Med Examiners Off, Tokyo 1120012, Japan
[2] Kanazawa Med Univ, Dept Legal Med, Uchinada, Ishikawa 9200293, Japan
[3] St Marianna Univ, Sch Med, Dept Legal Med, Kawasaki, Kanagawa 2168511, Japan
[4] Gunma Univ, Dept Legal Med, Grad Sch Med, Gunma 3718511, Japan
基金
日本学术振兴会;
关键词
Thoracic endovascular aortic repair; Open stent-grafting; Aortic esophageal fistula; Aortopulmonary fistula; Autopsy; AORTOESOPHAGEAL FISTULA; PLACEMENT;
D O I
10.1016/j.carpath.2018.12.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The mortality rate of aortic aneurysm/dissection is low in Japan. Two surgical procedures, the thoracic endovascular aortic repair (TEVAR) and the open gent-grafting have contributed much in survival of such aneu-rysmal patients. We encountered with two autopsy cases of death by aortic rupture with fistula formation after these procedures. Case 1 is an 85-year-old male who had the history of TEVAR for thoracic aorta aneurysm one and a half year before his death. His endovascular stem-graft was composed of a steel endoskeleton consisting of six Z-shape elements while at autopsy, one of the elements locating at the distal part was found inserted deep into the wall of descending aorta, causing aorto-esophageal fistula. Case 2 is an 88-year-old male who had the history of open stent-grafting for aortic aneurysm eight years ago. At autopsy, the stent-graft was found detached from aorta at its lesser curvature, causing gap formation between the aorta and the stent. Six Z-shaped stent elements, the parts of stent-graft, were found separated from descending aorta and located in the aneurism. Furthermore, three of the separated elements were found inserted deep in the aortic wall, causing aorto-pulmonary fistula. Since aorto-esophageal fistula formation after surgery for aortic aneurysm is very rare in TEVAR and there are no reported cases of death by aorto-pulmonary fistula in the open stent-grafting, these cases are reported here. (C) 2018 Elsevier Inc All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 14 条
[1]   Aorto-oesophageal and Aortobronchial Fistulae Following Thoracic Endovascular Aortic Repair: A National Survey [J].
Chiesa, R. ;
Melissano, G. ;
Marone, E. M. ;
Marrocco-Trischitta, M. M. ;
Kahlberg, A. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 39 (03) :273-279
[2]   PRIMARY AORTOESOPHAGEAL FISTULA FROM AORTIC-ANEURYSM - SUCCESSFUL SURGICAL-TREATMENT BY USE OF OMENTAL PEDICLE GRAFT [J].
COSELLI, JS ;
CRAWFORD, ES .
JOURNAL OF VASCULAR SURGERY, 1990, 12 (03) :269-277
[3]   Aorto-bronchial and aorto-pulmonary fistulation after thoracic endovascular aortic repair: an analysis from the European Registry of Endovascular Aortic Repair Complications [J].
Czerny, Martin ;
Reser, Diana ;
Eggebrecht, Holger ;
Janata, Karin ;
Sodeck, Gottfried ;
Etz, Christian ;
Luehr, Maximilian ;
Verzini, Fabio ;
Loschi, Diletta ;
Chiesa, Roberto ;
Melissano, Germano ;
Kahlberg, Andrea ;
Amabile, Philippe ;
Harringer, Wolfgang ;
Janosi, Rolf Alexander ;
Erbel, Raimund ;
Schmidli, Juerg ;
Tozzi, Piergiorgio ;
Okita, Yutaka ;
Canaud, Ludovic ;
Khoynezhad, Ali ;
Maritati, Gabriele ;
Cao, Piergiorgio ;
Koelbel, Tilo ;
Trimarchi, Santi .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 48 (02) :252-257
[4]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[5]   Aortoesophageal Fistula After Thoracic Aortic Stent-Graft Placement A Rare but Catastrophic Complication of a Novel Emerging Technique [J].
Eggebrecht, Holger ;
Mehta, Rajendra H. ;
Dechene, Alexander ;
Tsagakis, Konstantinos ;
Kuehl, Hilmar ;
Huptas, Sebastian ;
Gerken, Guido ;
Jakob, Heinz G. ;
Erbel, Raimund .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (06) :570-576
[6]  
Grande William, 2006, Semin Intervent Radiol, V23, P156, DOI 10.1055/s-2006-941446
[7]   Vocal cord paralysis after surgery for thoracic aortic aneurysm [J].
Ishimoto, S ;
Ito, K ;
Toyama, M ;
Kawase, I ;
Kondo, K ;
Oshima, K ;
Niimi, S .
CHEST, 2002, 121 (06) :1911-1915
[8]  
Kato M, 1996, CIRCULATION, V94, P188
[9]   The results of total arch graft implantation with open stent-graft placement for type A aortic dissection [J].
Kato, M ;
Kuratani, T ;
Kaneko, M ;
Kyo, S ;
Ohnishi, K .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (03) :531-540
[10]  
Ministry of Health Labor and welfare, DEM STAT