A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives

被引:46
作者
Cevik, Emre [2 ]
Senel, Mehmet [1 ]
Baykal, Abdulhadi [1 ]
Abasiyanik, M. Fatih [2 ]
机构
[1] Fatih Univ, Dept Chem, Fac Arts & Sci, TR-34500 Istanbul, Turkey
[2] Fatih Univ, Fac Engn, Dept Genet & Bioengn, TR-34500 Istanbul, Turkey
关键词
Horseradish peroxidase; Magnetic nanomaterials; Biosensor; Phenol; HORSERADISH-PEROXIDASE; HYDROGEN-PEROXIDE; GLUCOSE-OXIDASE; COVALENT IMMOBILIZATION; TYROSINASE; ELECTRODE; NANOBIOCOMPOSITE; CONDUCTIVITY; MICROSPHERES; FERROCENE;
D O I
10.1016/j.snb.2012.07.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of amperometric phenol biosensor was fabricated for the determination of phenol and its derivatives such as, phenol, catechol, p-cresol, 2-aminophenol and pyrogallol. The telomere of poly(glycidylmethacrylate) (PGMA) with a trimethoxysilyl terminal group was synthesized by telomerization of glycidylmethacrylate. Iron oxide nanoparticles were coated with telomere of poly(glycidylmethacrylate) in order to obtain good enzyme immobilization platform. PGMA covered Fe3O4 was covalently attached Au electrode surface and horseradish peroxidase (HRP) was immobilized on nanoparticles covered surface, respectively. The telomere, nanoparticles and modified electrodes were characterized by Fourier transform infrared (FT-IR), X-ray diffraction (XRD), transmission electron microscopy (TEM) and cyclic voltammetry (CV) before and after immobilization of HRP. Amperometric response was measured as a function of substrate concentration, at a fixed potential of -0.50 V vs. Ag/AgCl in phosphate-buffered saline (pH 7.5). Analytical parameters for the fabricated phenol biosensor were obtained from the calibration curves. The basic features (optimum pH, optimum temperature, reusability, and storage stability) of the enzyme electrode were determined. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:396 / 405
页数:10
相关论文
共 57 条
[1]   Immobilization of glucose oxidase on reagentless ferrocene-containing polythiophene derivative and its glucose sensing application [J].
Abasiyanik, M. Fatih ;
Senel, Mehmet .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 639 (1-2) :21-26
[2]  
[Anonymous], 1985, BEILSTEINS HDB ORG C
[3]  
[Anonymous], 1994, ENZYME HDB
[4]  
Bergmeyer H., 1970, Methoden der Enzymatischen Analyse
[5]   A novel thin film amperometric urea biosensor based on urease-immobilized on poly(N-glycidylpyrrole-co-pyrrole) [J].
Bozgeyik, Ibrahim ;
Senel, Mehmet ;
Cevik, Emre ;
Abasiyanik, M. Fatih .
CURRENT APPLIED PHYSICS, 2011, 11 (04) :1083-1088
[6]   Synthesis, characterisation and application of silica-magnetite nanocomposites [J].
Bruce, IJ ;
Taylor, J ;
Todd, M ;
Davies, MJ ;
Borioni, E ;
Sangregorio, C ;
Sen, T .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 284 :145-160
[7]   A novel bienzyme glucose biosensor based on three-layer Au-Fe3O4@SiO2 magnetic nanocomposite [J].
Chen, Xiaojun ;
Zhu, Jinwei ;
Chen, Zixuan ;
Xu, Chenbin ;
Wang, Yan ;
Yao, Cheng .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 159 (01) :220-228
[8]   CHROMATOGRAPHIC DETERMINATION OF PHENOLS IN WATER [J].
CHRISWELL, CD ;
CHANG, RC ;
FRITZ, JS .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1325-1329
[9]   MEDIATORLESS ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE AT GRAPHITE-ELECTRODES CHEMICALLY-MODIFIED WITH PEROXIDASES [J].
CSOREGI, E ;
JONSSONPETTERSSON, G ;
GORTON, L .
JOURNAL OF BIOTECHNOLOGY, 1993, 30 (03) :315-337
[10]   Synthesis and characterization of multifunctional poly(glycidyl methacrylate) microspheres and their use in cell separation [J].
Dong, Xiaoqing ;
Zheng, Yonghui ;
Huang, Yubin ;
Chen, Xuesi ;
Jing, Xiabin .
ANALYTICAL BIOCHEMISTRY, 2010, 405 (02) :207-212