Investigation of Noise-Induced Instabilities in Quantitative Biological Spectroscopy and Its Implications for Noninvasive Glucose Monitoring

被引:43
作者
Barman, Ishan [1 ]
Dingari, Narahara Chari [1 ]
Singh, Gajendra Pratap [1 ]
Soares, Jaqueline S. [1 ]
Dasari, Ramachandra R. [1 ]
Smulko, Janusz M. [1 ,2 ]
机构
[1] MIT, Laser Biomed Res Ctr, GR Harrison Spect Lab, Cambridge, MA 02139 USA
[2] Gdansk Univ Technol, Fac Elect Telecommun & Informat, PL-80233 Gdansk, Poland
关键词
RAMAN-SPECTROSCOPY; MULTIVARIATE CALIBRATION; CLASSIFICATION; REGRESSION; CANCER;
D O I
10.1021/ac301200n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Over the past decade, optical spectroscopy has been employed in combination with multivariate chemometric models to investigate a wide variety of diseases and pathological conditions, primarily due to its excellent chemical specificity and lack of sample preparation requirements. Despite promising results in several proof-of-concept studies, its translation to the clinical setting has often been hindered by inadequate accuracy of the conventional spectroscopic models. To address this issue and the possibility of curved (nonlinear) effects in the relationship between the concentrations of the analyte of interest and the mixture spectra (due to fluctuations in sample and environmental conditions), support vector machine-based least-squares nonlinear regression (LS-SVR) has been recently proposed. In this paper, we investigate the robustness of this methodology to noise-induced instabilities and present an analytical formula for estimating modeling precision as a function of measurement noise and model parameters. This formalism can be readily used to evaluate uncertainty in information extracted from spectroscopic measurements, particularly important for rapid-acquisition biomedical applications. Subsequently, using field data (Raman spectra) acquired from a glucose clamping study on an animal model subject, we perform the first systematic investigation of the relative effect of additive interference components (namely, noise in prediction spectra, calibration spectra, and calibration concentrations) on the prediction error of nonlinear spectroscopic models. Our results show that the LS-SVR method gives more accurate results and is substantially more robust to additive noise when compared with conventional regression methods such as partial least-squares regression (PLS), when careful selection of the LS-SVR model parameters are performed. We anticipate that these results will be useful for uncertainty estimation in similar biomedical applications where the precision of measurements and its response to noise in the data set is as important, if not more so, than the generic accuracy level.
引用
收藏
页码:8149 / 8156
页数:8
相关论文
共 45 条
  • [1] [Anonymous], 2000, AN INTRODUCTION TO S
  • [2] [Anonymous], 2011, ONGOING SPACE NUCL S
  • [3] Rapid and accurate determination of tissue optical properties using least-squares support vector machines
    Barman, Ishan
    Dingari, Narahara Chari
    Rajaram, Narasimhan
    Tunnell, James W.
    Dasari, Ramachandra R.
    Feld, Michael S.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2011, 2 (03): : 592 - 599
  • [4] Effect of photobleaching on calibration model development in biological Raman spectroscopy
    Barman, Ishan
    Kong, Chae-Ryon
    Singh, Gajendra P.
    Dasari, Ramachandra R.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
  • [5] Development of Robust Calibration Models Using Support Vector Machines for Spectroscopic Monitoring of Blood Glucose
    Barman, Ishan
    Kong, Chae-Ryon
    Dingari, Narahara Chari
    Dasari, Ramachandra R.
    Feld, Michael S.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (23) : 9719 - 9726
  • [6] Accurate Spectroscopic Calibration for Noninvasive Glucose Monitoring by Modeling the Physiological Glucose Dynamics
    Barman, Ishan
    Kong, Chae-Ryon
    Singh, Gajendra P.
    Dasari, Ramachandra R.
    Feld, Michael S.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (14) : 6104 - 6114
  • [7] Turbidity-Corrected Raman Spectroscopy for Blood Analyte Detection
    Barman, Ishan
    Singh, Gajendra P.
    Dasari, Ramachandra R.
    Feld, Michael S.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (11) : 4233 - 4240
  • [8] Analysis of luminescent samples using subtracted shifted Raman spectroscopy
    Bell, SEJ
    Bourguignon, ESO
    Dennis, A
    [J]. ANALYST, 1998, 123 (08) : 1729 - 1734
  • [9] Multicomponent blood analysis by near-infrared Raman spectroscopy
    Berger, AJ
    Koo, TW
    Itzkan, I
    Horowitz, G
    Feld, MS
    [J]. APPLIED OPTICS, 1999, 38 (13) : 2916 - 2926
  • [10] Analytical method of estimating chemometric prediction error
    Berger, AJ
    Feld, MS
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (05) : 725 - 732