A systematic review of experience of 180-W XPS GreenLight laser vaporisation of the prostate in 1640 men

被引:31
作者
Brunken, Claus [1 ]
Seitz, Christian [2 ]
Woo, Henry H. [3 ]
机构
[1] Asklepios Klin St Georg, Dept Urol, D-20099 Hamburg, Germany
[2] Med Univ Vienna, Dept Urol, Vienna, Austria
[3] Univ Sydney, Sydney Adventist Hosp, Sch Clin, Wharoonga, NSW, Australia
关键词
review; LUTS; BPH; laser; GreenLight; 180W; XPS; 532; nm; vaporisation; PHOTOSELECTIVE VAPORIZATION; MULTICENTER; HYPERPLASIA; EFFICACY; THERAPY; PARAMETERS; SAFETY; COHORT;
D O I
10.1111/bju.12955
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective To systematically review the literature regarding clinical outcomes of 180-W XPS GreenLight (R) laser (GL) vaporisation for the treatment of lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH). Methods Recent publications were identified in the field of 180-W GL vaporisation for the treatment of LUTS due to BPH. We searched for peer-reviewed original articles in the English language. Search items were: '180W lithium triborate laser' or '180W greenlight laser' or '180 watt lithium triborate laser' or '180 watt greenlight laser' or 'XPS greenlight laser'. In all, 30 papers published between 2012 and 2014 matched this search. Of these, 10 papers were identified dealing with consecutive cohorts of patients treated with the 180-W XPS GL Results The 10 papers included a total experience of 1640 patients. The only randomised controlled trial in this field compares 180-W with transurethral resection of the prostate (TURP). Functional outcomes and prostate volume reduction after GL vaporisation were similar to TURP. Catheterisation time and hospital stay were shorter in patients undergoing 180W XPS GL vaporisation (41 and 66 h vs 60 and 97 h, respectively). Four papers compared the 180-W XPS system to former GL devices showing increased operation time efficiency and comparable postoperative voiding results and adverse events. One paper defined the learning curve to achieve an expert level according to the speed of the procedure and the effectiveness of volume reduction was met after 120 procedures. Conclusion The 180-W XPS GL offers shorter operation times than former devices. In the one randomised controlled trial comparison with TURP, volume reduction and functional results were comparable to those of TURP. Longer term studies are required.
引用
收藏
页码:531 / 537
页数:7
相关论文
共 23 条
[1]  
Bachmann A, 2014, 29 ANN EAU C STOCKH
[2]   180-W XPS GreenLight Laser Vaporisation Versus Transurethral Resection of the Prostate for the Treatment of Benign Prostatic Obstruction: 6-Month Safety and Efficacy Results of a European Multicentre Randomised Trial-The GOLIATH Study [J].
Bachmann, Alexander ;
Tubaro, Andrea ;
Barber, Neil ;
d'Ancona, Frank ;
Muir, Gordon ;
Witzsch, Ulrich ;
Grimm, Marc-Oliver ;
Benejam, Joan ;
Stolzenburg, Jens-Uwe ;
Riddick, Antony ;
Pahernik, Sascha ;
Roelink, Herman ;
Ameye, Filip ;
Saussine, Christian ;
Bruyere, Franck ;
Loidl, Wolfgang ;
Larner, Tim ;
Gogoi, Nirjan-Kumar ;
Hindley, Richard ;
Muschter, Rolf ;
Thorpe, Andrew ;
Shrotri, Nitin ;
Graham, Stuart ;
Hamann, Moritz ;
Miller, Kurt ;
Schostak, Martin ;
Capitan, Carlos ;
Knispel, Helmut ;
Thomas, J. Andrew .
EUROPEAN UROLOGY, 2014, 65 (05) :931-942
[3]   180-W XPS GreenLight Laser Therapy for Benign Prostate Hyperplasia: Early Safety, Efficacy, and Perioperative Outcome After 201 Procedures [J].
Bachmann, Alexander ;
Muir, Gordon H. ;
Collins, Edward J. ;
Choi, Benjamin B. ;
Tabatabaei, Shahin ;
Reich, Oliver M. ;
Gomez-Sancha, Fernando ;
Woo, Henry H. .
EUROPEAN UROLOGY, 2012, 61 (03) :600-607
[4]   GreenLight XPS 180W vs HPS 120W Laser Therapy for Benign Prostate Hyperplasia: A Prospective Comparative Analysis After 200 Cases in a Single-center Study [J].
Ben-Zvi, Tal ;
Hueber, Pierre-Alain ;
Liberman, Daniel ;
Valdivieso, Roger ;
Zorn, Kevin C. .
UROLOGY, 2013, 81 (04) :853-858
[5]   The 532-nm 180-W (GreenLight®) laser vaporization of the prostate for the treatment of lower urinary tract symptoms: how durable is the new side-fire fiber with integrated cooling system? [J].
Brunken, Claus ;
Munsch, Maximilian ;
Tauber, Stephan ;
Schmidt, Rainer ;
Seitz, Christian .
LASERS IN MEDICAL SCIENCE, 2014, 29 (03) :1307-1312
[6]   Penetration Depth with the XPS GreenLight Laser Assessed by Contrast Enhanced Ultrasonography [J].
Bruyere, Franck ;
Bodin, Thomas ;
Bleuzen, Aurore ;
Patat, Frederic ;
Brunereau, Laurent .
JOURNAL OF ENDOUROLOGY, 2013, 27 (10) :1282-1286
[7]   Early experience photoselective vaporisation of the prostate using the 180W lithium triborate and comparison with the 120W lithium triborate laser [J].
Campbell, Nicholas A. ;
Chung, Amanda S. J. ;
Yoon, Peter D. ;
Thangasamy, Isaac ;
Woo, Henry H. .
PROSTATE INTERNATIONAL, 2013, 1 (01) :42-45
[8]   Photoselective vaporization of the prostate using the 180W lithium triborate laser [J].
Chung, Amanda S. J. ;
Chabert, Charles ;
Yap, Hin-Wai ;
Lam, Jimmy ;
Awad, Nader ;
Nuwayhid, Fadi ;
Redwig, Frank ;
Rashid, Prem ;
Woo, Henry H. .
ANZ JOURNAL OF SURGERY, 2012, 82 (05) :334-337
[9]   Classification of surgical complications - A new proposal with evaluation in a cohort of 6336 patients and results of a survey [J].
Dindo, D ;
Demartines, N ;
Clavien, PA .
ANNALS OF SURGERY, 2004, 240 (02) :205-213
[10]   The Continuous Evolution of the Greenlight Laser; the XPS Generator and the MoXy Laser Fiber, Expanding the Indications for Photoselective Vaporization of the Prostate [J].
Emara, Amr M. ;
Barber, Neil J. .
JOURNAL OF ENDOUROLOGY, 2014, 28 (01) :73-78