Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study

被引:5
作者
Andreasen, Lene N. [1 ]
Holm, Niels R. [1 ]
Balleby, Ida R. [1 ]
Krusell, Lars R. [1 ]
Maeng, Michael [1 ]
Jakobsen, Lars [1 ]
Veien, Karsten T. [2 ]
Hansen, Knud N. [2 ]
Kristensen, Steen D. [1 ]
Hjort, Jakob [3 ]
Kaltoft, Anne [1 ]
Dijkstra, Jouke [4 ]
Terkelsen, Christian J. [1 ]
Lassen, Jens F. [1 ]
Madsen, Morten [5 ]
Botker, Hans Erik [1 ]
Jensen, Lisette O. [2 ]
Christiansen, Evald H. [1 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
[2] Odense Univ Hosp, Dept Cardiol, Sondre Blvd 29, DK-5000 Odense C, Denmark
[3] Aarhus Univ Hosp, Inst Clin Med, Skejby, Denmark
[4] Leiden Univ, Med Ctr, Div Image Proc, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[5] Aarhus Univ Hosp, Dept Clin Epidemiol, Skejby, Denmark
关键词
drug-eluting stents; bioresorbable polymer stents; optical coherence tomography; INTRAVASCULAR ULTRASOUND; CORONARY INTERVENTIONS; NEOINTIMAL COVERAGE; IMPLANTATION; THROMBOSIS; EVAGINATIONS; APPOSITION; MECHANISMS; RESTENOSIS; ANEURYSMS;
D O I
10.1093/ehjci/jex035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To show non-inferiority of the 67- or 87 mu m thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 mu m thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up. Methods and results This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Delta = 0.60 mm(2)) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro (n = 60) or Nobori (n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm(2), but increased to 0.82 mm(2) after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm(2) [0.02; 0.30] mm(2), Nobori: 0.03 mm(2) [0.00; 0.17] mm(2), P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8; 99.4]%, and Nobori: 96.3 % [90.5; 98,6]% (P = 0.13). Conclusion Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution of neointima but stent strut coverage did not differ significantly between the two stents.
引用
收藏
页码:329 / 338
页数:10
相关论文
共 26 条
  • [1] Coronary Aneurysms After Drug-Eluting Stent Implantation Clinical, Angiographic, and Intravascular Ultrasound Findings
    Alfonso, Fernando
    Perez-Vizcayno, Maria-Jose
    Ruiz, Miguel
    Suarez, Alfonso
    Cazares, Miguel
    Hernandez, Rosana
    Escaned, Javier
    Banuelos, Camino
    Jimenez-Quevedo, Pilar
    Macaya, Carlos
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (22) : 2053 - 2060
  • [2] Coronary Artery Aneurysms After Drug-Eluting Stent Implantation
    Aoki, Jiro
    Kirtane, Ajay
    Leon, Martin B.
    Dangas, George
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (01) : 14 - 21
  • [3] An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study
    Barlis, Peter
    Regar, Evelyn
    Serruys, Patrick W.
    Dimopoulos, Konstantinos
    van der Giessen, Willem J.
    van Geuns, Robert-Jan M.
    Ferrante, Giuseppe
    Wandel, Simon
    Windecker, Stephan
    van Es, Gerrit-Anne
    Eerdmans, Pedro
    Jueni, Peter
    di Mario, Carlo
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (02) : 165 - 176
  • [4] Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization
    Finn, Aloke V.
    Joner, Michael
    Nakazawa, Gaku
    Kolodgie, Frank
    Newell, John
    John, Mike C.
    Gold, Herman K.
    Virmani, Renu
    [J]. CIRCULATION, 2007, 115 (18) : 2435 - 2441
  • [5] Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance Implications for the Management of Incomplete Stent Apposition
    Foin, Nicolas
    Gutierrez-Chico, Juan Luis
    Nakatani, Shimpei
    Torii, Ryo
    Bourantas, Christos V.
    Sen, Sayan
    Nijjer, Sukhjinder
    Petraco, Ricardo
    Kousera, Chrysa
    Ghione, Matteo
    Onuma, Yoshinobu
    Garcia-Garcia, Hector M.
    Francis, Darrel P.
    Wong, Philip
    Di Mario, Carlo
    Davies, Justin E.
    Serruys, Patrick W.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (02) : 180 - 189
  • [6] Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal Stent coronary interventions
    Jensen, Lisette Okkels
    Maeng, Michael
    Kaltoft, Anne
    Thayssen, Per
    Hansen, Hans Henrik Tilsted
    Bottcher, Morten
    Lassen, Jens Flensted
    Krussel, Lars Romer
    Rasmussen, Klaus
    Hansen, Knud Noerregaard
    Pedersen, Lars
    Johnsen, Soeren Paaske
    Soerensen, Henrik Toft
    Thuesen, Leif
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (05) : 463 - 470
  • [7] Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention The SORT OUT VII Trial
    Jensen, Lisette Okkels
    Thayssen, Per
    Maeng, Michael
    Ravkilde, Jan
    Krusell, Lars Romer
    Raungaard, Bent
    Junker, Anders
    Terkelsen, Christian Juhl
    Veien, Karsten Tange
    Villadsen, Anton Boel
    Kaltoft, Anne
    Tilsted, Hans-Henrik
    Hansen, Knud Norregaard
    Aaroe, Jens
    Kristensen, Steen Dalby
    Hansen, Henrik Steen
    Jensen, Svend Eggert
    Madsen, Morten
    Botker, Hans Erik
    Berencsi, Klara
    Lassen, Jens Flensted
    Christiansen, Evald Hoj
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [8] Safety and Efficacy of Everolimus-Versus Sirolimus-Eluting Stents 5-Year Results From SORT OUT IV
    Jensen, Lisette Okkels
    Thayssen, Per
    Christiansen, Evald Hoj
    Maeng, Michael
    Ravkilde, Jan
    Hansen, Knud Norregaard
    Hansen, Henrik Steen
    Krusell, Lars
    Kaltoft, Anne
    Tilsted, Hans Henrik
    Berencsi, Klara
    Junker, Anders
    Lassen, Jens Flensted
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (07) : 751 - 762
  • [9] Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk
    Joner, Michael
    Finn, Aloke V.
    Farb, Andrew
    Mont, Erik K.
    Kolodgie, Frank D.
    Ladich, Elena
    Kutys, Robert
    Skorija, Kristi
    Gold, Herman K.
    Virmani, Renu
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) : 193 - 202
  • [10] Early Neointimal Coverage and Vasodilator Response Following Biodegradable Polymer Sirolimus-Eluting vs. Durable Polymer Zotarolimus-Eluting Stents in Patients With Acute Coronary Syndrome - HATTRICK-OCT Trial -
    Karjalainen, Pasi P.
    Varho, Ville
    Nammas, Wail
    Mikkelsson, Jussi
    Pietila, Mikko
    Ylitalo, Antti
    Airaksinen, Juhani K. E.
    Sia, Jussi
    Nyman, Kai
    Biancari, Fausto
    Kiviniemi, Tuomas
    [J]. CIRCULATION JOURNAL, 2015, 79 (02) : 360 - 367