Intraocular pressure fluctuation after water drinking test in primary angle-closure glaucoma and primary open-angle glaucoma

被引:10
作者
Poon, Yi-Chieh [1 ]
Teng, Mei-Ching [1 ]
Lin, Pei-Wen [1 ]
Tsai, Jen-Chia [1 ]
Lai, Ing-Chou [1 ]
机构
[1] Chang Gung Univ, Coll Med, Dept Ophthalmol, Kaohsiung Chang Gung Mem Hosp, Kaohsiung, Taiwan
关键词
Intraocular pressure; primary angle-closure glaucoma; primary open-angle glaucoma; water drinking test; CHOROIDAL THICKNESS; RISK-FACTOR; PROGRESSION; TRIAL; VOLUME; EYES;
D O I
10.4103/0301-4738.198851
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Context: Only a few studies have assessed intraocular pressure (IOP) changes during the water drinking test (WDT) in patients with primary angle-closure glaucoma (PACG). Aims: The aim of this study is to investigate IOP changes during WDT in patients with PACG versus primary open-angle glaucoma (POAG). Settings and Design: This was a prospective and single tertiary center study. Materials and Methods: PACG and POAG patients (n = 15 each) without prior glaucoma surgery were enrolled and subjected to WDT, wherein they consumed an amount of water proportional to their body weight within 10 min. IOP was measured at baseline and every 15 min for 1 h after water intake. Statistical Analysis Used: Intergroup comparisons were performed using Mann-Whitney U-test for continuous variables and Chi-square test for categorical variables. Wilcoxon signed-ranks test was used for comparisons of IOP before and after water intake in the two groups. Regression analysis was used to determine factors associated with IOP fluctuations during WDT. Results: IOP changes over 1 h after water intake showed no significant differences between groups. The mean maximum fluctuation from baseline was 3.61 +/- 2.49 and 3.79 +/- 1. 91 mmHg, respectively, in the PACG and POAG groups. The mean peak IOP was 19.17 +/- 4.32 and 19.87 +/- 3.44 mmHg in the PACG and PAOG groups, respectively. The axial length and anterior chamber depth showed no correlations with IOP fluctuations. Conclusions: We found similar IOP fluctuation curves and peak IOP values in both PACG and POAG patients subjected to WDT. These findings suggest that WDT is a useful test to induce IOP peaks in both POAG and PACG patients.
引用
收藏
页码:919 / 923
页数:5
相关论文
共 36 条
[1]  
Alward WL, 1998, AM J OPHTHALMOL, V126, P498
[2]   Choroidal Thickness Change after Water Drinking Is Greater in Angle Closure than in Open Angle Eyes [J].
Arora, Karun S. ;
Jefferys, Joan L. ;
Maul, Eugenio A. ;
Quigley, Harry A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (10) :6393-6402
[3]  
Asrani S, 2000, J GLAUCOMA, V9, P134
[4]   Diurnal Intraocular Pressure Fluctuation and Associated Risk Factors in Eyes with Angle Closure [J].
Baskaran, Mani ;
Kumar, Rajesh S. ;
Govindasamy, Chitra V. ;
Htoon, Hla Myint ;
Wong, Ching-Yee ;
Perera, Shamira A. ;
Wong, Tina T. L. ;
Aung, Tin .
OPHTHALMOLOGY, 2009, 116 (12) :2300-2304
[5]   Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial [J].
Bengtsson, Boel ;
Leske, M. Cristina ;
Hyman, Leslie ;
Heijl, Anders .
OPHTHALMOLOGY, 2007, 114 (02) :205-209
[6]   Intraocular pressure fluctuation - A risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study [J].
Caprioli, Joseph ;
Coleman, Anne L. .
OPHTHALMOLOGY, 2008, 115 (07) :1123-1129
[7]   The water-drinking test: The elegance of simplicity [J].
Danesh-Meyer, Helen V. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 36 (04) :301-303
[8]   Short- and Long-Term Phasing of Intraocular Pressure in Stable and Progressive Glaucoma [J].
Fogagnolo, Paolo ;
Orzalesi, Nicola ;
Centofanti, Marco ;
Oddone, Francesco ;
Manni, Gianluca ;
Rossetti, Luca .
OPHTHALMOLOGICA, 2013, 230 (02) :87-92
[9]   The Circadian Curve of Intraocular Pressure: Can We Estimate Its Characteristics during Office Hours? [J].
Fogagnolo, Paolo ;
Orzalesi, Nicola ;
Ferreras, Antonio ;
Rossetti, Luca .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (05) :2209-2215
[10]   Postural and diurnal fluctuations in intraocular pressure across the spectrum of glaucoma [J].
Gautam, Natasha ;
Kaur, Savleen ;
Kaushik, Sushmita ;
Raj, Srishti ;
Pandav, Surinder Singh .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (04) :537-541