OCCUPATIONAL RADIATION DOSE PERFORMING HEPATOBILIARY MINIMALLY INVASIVE PROCEDURES IN CHILDREN WEIGHING LESS THAN 20 kg

被引:1
作者
Gerasia, Roberta [1 ]
Cannataci, Christine [2 ]
Maruzzelli, Luigi [1 ]
Caruso, Calogero [1 ]
Liotta, Ferdinanda [1 ]
Cucchiara, Antonino [1 ]
Cortis, Kelvin [2 ]
Miraglia, Roberto [1 ]
机构
[1] Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tric 5, I-90127 Palermo, Italy
[2] Mater Dei Hosp, Med Imaging Dept, MSD-9032 Msida, Malta
关键词
RADIOLOGY; SYSTEM;
D O I
10.1093/rpd/ncz260
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Our objective is to retrospectively evaluate the effective dose (E) of operators performing pediatric Hepatobiliary Minimally Invasive Procedures (HMIP). Between October 2015 and December 2017, 58 consecutive HMIP were performed on 26 children weighing less than 20 kg (mean 12.3 kg, median 13 kg, range 2.4-20 kg). About 31 vascular procedures (n = 9 hepatic venograms with/without stenting; n = 9 retrograde wedge portography; n = 8 transhepatic portography with angioplasty and/or stenting and n = 5 hepatic arteriography/embolization) and 27 non-vascular procedures (n = 6 percutaneous transhepatic biliary drainage (PTBD); n = 3 bilioplasty; n = 15 biliary catheter change and n = 3 cholangiogram) were performed. Electronic personal dosimeters were used to measure radiation doses to the interventional radiologist, radiographer and anesthesia nurse. The results shows the highest mean effective dose: interventional radiologist's in PTBD (1.18 mu Sv); radiographer's in hepatic veins phlebography with/without stenting (0.25 mu Sv) and nurse's in hepatic arteriography/embolization (0.26 mu Sv). Operators' E can vary depending on the complexity of procedure performed and the position of the operators within the angiosuite.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 20 条
  • [1] Considerations concerning the use of counting active personal dosemeters in pulsed fields of ionising radiation
    Ambrosi, Peter
    Borowski, Markus
    Iwatschenko, Michael
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (04) : 483 - 493
  • [2] [Anonymous], 2010, 606012432010 IEC
  • [3] Cho K-W., 2018, Annals of the ICRP, V47, P1, DOI 10.1177/0146645317746010
  • [4] Removal of the Antiscatter Grid During Routine Biliary Interventional Procedures Performed in a Flat-Panel Interventional Suite: Preliminary Data on Image Quality and Patient Radiation Exposure
    Cortis, Kelvin
    Miraglia, Roberto
    Maruzzelli, Luigi
    Gerasia, Roberta
    Tafaro, Corrado
    Luca, Angelo
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (04) : 1078 - 1082
  • [5] Radiation Doses to Operators in Hepatobiliary Interventional Procedures
    Degiorgio, Sarah
    Gerasia, Roberta
    Liotta, Ferdinanda
    Maruzzelli, Luigi
    Cortis, Kelvin
    Miraglia, Roberto
    Luca, Angelo
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (05) : 772 - 780
  • [6] Meso-Rex Bypass-A Procedure to Cure Prehepatic Portal Hypertension: The Insight and the Inside
    di Francesco, Fabrizio
    Grimaldi, Chiara
    de Goyet, Jean de Ville
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 218 (02) : E23 - E36
  • [7] A formula to estimate the approximate surface area if height and weight be known
    Du Bois, D
    Du Bois, EF
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1916, 17 (06) : 863 - 871
  • [8] THE RELATIONSHIP OF EFFECTIVE DOSE TO PERSONNEL AND MONITOR READING FOR SIMULATED FLUOROSCOPIC IRRADIATION CONDITIONS
    FAULKNER, K
    MARSHALL, NW
    [J]. HEALTH PHYSICS, 1993, 64 (05): : 502 - 508
  • [9] IAEA, 2007, IAEA SAFETY GLOSSARY, P1
  • [10] Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Jansen, J.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    d'Errico, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 333 - 339