Finite element analysis of the stability of transverse acetabular fractures in standing and sitting positions by different fixation options

被引:23
作者
Yildirim, Ahmet Ozgur [1 ,2 ]
Alemdaroglu, Kadir Bahadir [3 ,4 ]
Yuksel, Halil Yalcin [5 ]
Oken, Ozdamar Fuad [1 ,2 ]
Ucaner, Ahmet [1 ,2 ]
机构
[1] Ankara Numune Training & Res Hosp, Orthopaed Clin, Ankara, Turkey
[2] Ankara Numune Training & Res Hosp, Traumatol Clin, Ankara, Turkey
[3] Ankara Numune Training & Res Hosp, Orthopaed Clin, Ankara, Turkey
[4] Ankara Numune Training & Res Hosp, Traumatol Clin, Ankara, Turkey
[5] Antalya Training & Res Hosp, Antalya, Turkey
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷
关键词
Transvers acetabular fracture; Finite element; Stability; Biomechanic; OPERATIVE TREATMENT; REDUCTION; SCREW; SYSTEMS;
D O I
10.1016/j.injury.2015.05.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Treatment of a transverse acetabular fracture type is possible from an anterior approach, a posterior approach or both. Different fixation methods have been described but whether one is superior to the other is still under debate. The aim of the current study was to test the different fixation alternatives of stabilization of transverse acetabular fractures under two basic physiological loading conditions: standing and sitting utilizing a finite element model. Material and methods: A transtectal transverse fracture model was fixed in five different alternatives: an anterior column plate; a posterior column plate; an anterior column plate combined with a posterior column screw; a posterior column plate combined with an anterior column screw; and a posterior column plate and an anterior column plate. In these models, a load of 400 N was applied at standing and sitting positions and the displacements were analyzed by using three-dimensional finite element stress analysis method. Results: In the model simulating standing human position, overall motion at the posterior column was minimum when two columns were plated (0.071 mm). The second best fixation was posterior column plate with an anterior column screw (0.077 mm). Overall motion at the anterior column was minimum by posterior column plate with an anterior column screw (0.0326 mm). The plating of two columns was associated with motion of (0.0333 mm). In the model that simulates sitting position, the motion at the posterior column was minimum when two columns were plated (0.0478 mm), and (0.0517 mm) when a posterior column plate with an anterior column screw was used. Overall motion in the anterior column was minimum when posterior column plate with an anterior column screw (0.0198 mm) was used, whereas the motion was (0.0203 mm) when plating of both columns was examined. Conclusion: Posterior column plating combined with an anterior column screw has quite comparable results to a both column plating in transverse fractures, suggesting that two column fixations might be unnecessary. This method is also very superior to anterior column plating combined with a posterior column screw in that type of fractures. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S29 / S35
页数:7
相关论文
共 21 条
[1]  
Atchison SM, 1995, P 14 SO BIOM ENG C, P55
[2]   Quality of Radiographic Reduction and Perioperative Complications for Transverse Acetabular Fractures Treated by the Kocher-Langenbeck Approach: Prone Versus Lateral Position [J].
Collinge, Cory ;
Archdeacon, Michael ;
Sagi, H. Claude .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (09) :538-542
[3]   Operative treatment of displaced fractures of the acetabulum - A meta-analysis [J].
Giannoudis, PV ;
Grotz, MRW ;
Papakostidis, C ;
Dinopoulos, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (01) :2-9
[4]  
Giordano V, 2009, INT J MED SCI, V6, P192
[5]   Screw- versus plate-fixation strength of acetabular anterior column fractures: A biomechanical study [J].
Gras, Florian ;
Marintschev, Ivan ;
Schwarz, Christoph E. ;
Hofmann, Gunther O. ;
Pohlemann, Tim ;
Culemann, Ulf .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (06) :1664-1670
[6]   Fractures of the acetabulum in elderly patients: An update [J].
Guerado, E. ;
Cano, J. R. ;
Cruz, E. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 :S33-S41
[7]   A finite element analysis of the pelvic reconstruction using fibular transplantation fixed with four different rod-screw systems after type I resection [J].
Jia Yong-Wei ;
Cheng Li-Ming ;
Yu Guang-Rong ;
Du Cheng-fei ;
Yang Zhi-yong ;
Yu Yan ;
Ding Zu-quan .
CHINESE MEDICAL JOURNAL, 2008, 121 (04) :321-326
[8]   FRACTURES OF THE ACETABULUM - CLASSIFICATION AND SURGICAL APPROACHES FOR OPEN REDUCTION - PRELIMINARY REPORT [J].
JUDET, R ;
JUDET, J ;
LETOURNEL, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1964, 46 (08) :1615-&
[9]   Acetabular loading in active abduction [J].
Kristan, Anze ;
Mavcic, Blaz ;
Cimerman, Matej ;
Iglic, Ales ;
Tonin, Martin ;
Slivnik, Tomaz ;
Kralj-Iglic, Veronika ;
Daniel, Matej .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (02) :252-257
[10]   Operative management of acetabular fractures - A review of 73 fractures [J].
Kumar, A ;
Shah, NA ;
Kershaw, SA ;
Clayson, AD .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (05) :605-612