Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

被引:0
|
作者
Sriraman, Aishwarya [1 ]
Fifield, Leonard S. [1 ]
Glass, S. W. [1 ]
Spencer, Mychal [1 ]
Prowant, Matthew S. [1 ]
Guzman, Anthony [1 ]
机构
[1] Pacif Northwest Natl Lab PNNL, Richland, WA 99354 USA
来源
2022 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP 2022) | 2022年
关键词
D O I
10.1109/CEIDP55452.2022.9985311
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 V-AC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 degrees C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 degrees C) and with the oven off (at 22 degrees C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 degrees C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 50 条
  • [1] Influence of Temperature on Wave Propagation in Low-Voltage Distribution Cables
    van Deursen, Armand
    Wouters, Peter
    Steennis, Fred
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (05) : 1785 - 1792
  • [2] Converter Stress Impact on Thermally Aged Resin for Low-Voltage Machines
    Rumi, Alberto
    Marinelli, Jacopo Gabriele
    Cavallini, Andrea
    2021 96TH IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP 2021) / 16TH IEEE NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (IEEE NMDC 2021), 2021, : 40 - 43
  • [3] LOCALIZATION OF FAULTS IN LOW-VOLTAGE CABLES
    不详
    NATURE, 1945, 156 (3955) : 201 - 201
  • [4] Spatial Temperature Measurement of Low-Voltage Cluster Cables With Electronic Nose
    Lei, Fangfei
    Chu, Jifeng
    Yue, Xianghong
    Pan, Jianbin
    Yang, Aijun
    Yuan, Huan
    Rong, Mingzhe
    Wang, Xiaohua
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [5] MODERN LOW-VOLTAGE CABLES FOR INDUSTRIAL INSTALLATIONS
    PHILBRICK, S
    ELECTRICAL REVIEW, 1976, 198 (09): : 21 - 22
  • [6] Condition Management of Low-Voltage Distribution Cables
    Cselko, Richard
    Balogh, Daniel
    Kalecz, Gyorgy
    Nemeth, Balint
    Hartmann, Balint
    2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 128 - 131
  • [7] Investigation of the Structural Dependence of the Cyclical Thermal Aging of Low-Voltage PVC-Insulated Cables
    Bal, Semih
    Tamus, Zoltan Adam
    SYMMETRY-BASEL, 2023, 15 (06):
  • [8] Intermittent arcing fault on underground low-voltage cables
    Hamel, A
    Gaudreau, A
    Côté, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) : 1862 - 1868
  • [9] Research on the Coupling between High-voltage Cables and Low-voltage Cables in Electric Vehicles
    Wang, Huihui
    Gao, Changsheng
    Han, Hongji
    Ren, Jie
    Zhang, Dan
    2023 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS, ICEAA, 2023, : 273 - 276
  • [10] Partial discharge characteristics of NYCY low-voltage cables
    Cselko, Richard
    Garcia, Mario Macos
    Berta, Istvan
    2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 138 - 141