The Influence of Central Corneal Thickness and Corneal Curvature Radius on The Intraocular Pressure as Measured By Different Tonometers: Noncontact and Goldmann Applanation Tonometers

被引:37
作者
Harada, Yukinori [1 ]
Hirose, Naofumi [2 ]
Kubota, Toshiaki
Tawara, Akihiko
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Ophthalmol, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Sakka Eye Clin, Kitakyushu, Fukuoka, Japan
关键词
intraocular pressure; central corneal thickness; corneal curvature radius; Goldmann applanation tonometer; noncontact tonometer;
D O I
10.1097/IJG.0b013e3181634f0f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to examine whether or not central corneal thickness (CCT) and corneal curvature radius (CCR) influence the concordance of intraocular pressuree (IOP) readings taken with a noncontact tonometer (NCT) and a Goldmann applanalion tonometer (GAT). Methods: Eighty-seven eves from 87 patients without any histories of intraocular operation were enrolled in the present study. We calculated the difference in IOP readings between the Methods (NCT-GAT). and then examined the relationship between the IOP readings. and CCT and CCR using a linear regression line. Results: IOP measured by both NCT (r = 0.515 P < 0.0001) and GAT (r = 0.237. P < 0.05) was significantly correlated with CCT. NCT readings were significantly higher in the thicket group (CCT >= 526.9 mu m) than in the thinner group (CCT < 526.9 mu m) (P < 0.005). GAT readings had no difference between the thicker and thinner groups. 10P measured by GAT (r = -0.261 P < 0.05). but not that measured by NCT (r = -0.111. P = 0.3042). showed a significant negative correlation with CCR. An IOP value of(NCT-GAT) had a significant positive correlation with not only CCT (r = 0.666, P < 0.0001) also CCR (r = 0.227. P < 0.05). The value of (NCT-GAT) was significantly higher in the thicker group than in the thinner group (P < 0.005). Conclusions: NCT can be more affected by CCT than GAT. CCR could influence the measurements of GAT, but not those by NCT. CCT and CCR can therefore influence the discordance of 1011 readings taken with NCT and GAT.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 22 条
[1]   Influence of corneal variables on accuracy of intraocular pressure measurement [J].
Damji, KF ;
Muni, RH ;
Munger, RM .
JOURNAL OF GLAUCOMA, 2003, 12 (01) :69-80
[2]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P652
[3]  
EHLERS N, 1976, ACTA OPHTHALMOL, V54, P774
[4]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[5]   Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonomet [J].
Francis, Brian A. ;
Hsieh, Amy ;
Lai, Mei-Ying ;
Chopra, Vikas ;
Pena, Fernando ;
Azen, Stanley ;
Varma, Rohit .
OPHTHALMOLOGY, 2007, 114 (01) :20-26
[6]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[7]  
GOLDMANN H, 1961, Ophthalmologica, V141, P441
[8]  
GROLMAN B, 1972, AMER J OPT ARCH AM A, V49, P646
[9]   Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer [J].
Gunvant, P ;
Baskaran, M ;
Vijaya, L ;
Joseph, IS ;
Watkins, RJ ;
Nallapothula, M ;
Broadway, DC ;
O'Leary, DJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) :518-522
[10]   Evaluation of tonometric correction factors [J].
Gunvant, P ;
Oleary, DJ ;
Baskaran, M ;
Broadway, DC ;
Watkins, RJ ;
Vijaya, L .
JOURNAL OF GLAUCOMA, 2005, 14 (05) :337-343