Computational Fluid Dynamics Simulations of Contrast Agent Bolus Dispersion in a Coronary Bifurcation: Impact on MRI-Based Quantification of Myocardial Perfusion

被引:8
作者
Schmidt, Regine [1 ]
Graafen, Dirk [1 ]
Weber, Stefan [1 ]
Schreiber, Laura M. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Radiol, Sect Med Phys, D-55131 Mainz, Germany
关键词
POSITRON-EMISSION-TOMOGRAPHY; VESSEL WALL ELASTICITY; BLOOD-FLOW; MAGNETIC-RESONANCE; BYPASS GRAFT; MODEL; ADENOSINE; PARAMETERS; RESISTANCE; VELOCITY;
D O I
10.1155/2013/513187
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between the LV and the myocardial tissue. Negligence of bolus dispersion could cause an error in MBF determination. The aim of this study was to investigate the influence of bolus dispersion in a simplified coronary bifurcation geometry including one healthy and one stenotic branch on the quantification of MBF and MPR. Computational fluid dynamics (CFD) simulations were combined with MMID4. Different inlet boundary conditions describing pulsatile and constant flows for rest and hyperemia and differing outflow conditions have been investigated. In the bifurcation region, the increase of the dispersion was smaller than inside the straight vessels. A systematic underestimation of MBF values up to -16.1% for pulsatile flow and an overestimation of MPR up to 7.5% were found. It was shown that, under the conditions considered in this study, bolus dispersion can significantly influence the results of quantitative myocardial MR-perfusion measurements.
引用
收藏
页数:13
相关论文
共 51 条
[1]   Usefulness of hemodynamic changes during adenosine infusion in predicting the diagnostic accuracy of adenosine technetium-99m sestamibi single-photon emission computed tomography (SPECT) [J].
Amanullah, AM ;
Berman, DS ;
Kiat, H ;
Friedman, JD .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (10) :1319-1322
[2]  
[Anonymous], 2009, USER MANUAL ANSYS IC
[3]  
Arslan N., 2005, P 3 EUR MED BIOL ENG
[4]  
Barton IE, 1998, INT J NUMER METH FL, V26, P459, DOI 10.1002/(SICI)1097-0363(19980228)26:4<459::AID-FLD645>3.0.CO
[5]  
2-U
[6]   Bolus delay and dispersion in perfusion MRI: Implications for tissue predictor models in stroke [J].
Calamante, F ;
Willats, L ;
Gadian, DG ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1180-1185
[7]   Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics [J].
Calamante, F ;
Yim, PJ ;
Cebral, JR .
NEUROIMAGE, 2003, 19 (02) :341-353
[8]  
Chaichanas T, 2012, COMPUT MATH METHOD M, V2012, DOI DOI 10.1155/2012/504367
[9]   SENSOP - A DERIVATIVE-FREE SOLVER FOR NONLINEAR LEAST-SQUARES WITH SENSITIVITY SCALING [J].
CHAN, IS ;
GOLDSTEIN, AA ;
BASSINGTHWAIGHTE, JB .
ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (06) :621-631
[10]   REDISTRIBUTION OF CORONARY MICROVASCULAR RESISTANCE PRODUCED BY DIPYRIDAMOLE [J].
CHILIAN, WM ;
LAYNE, SM ;
KLAUSNER, EC ;
EASTHAM, CL ;
MARCUS, ML .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (02) :H383-H390