Development of multipoint vibrational coherent anti-Stokes Raman spectroscopy for flame applications

被引:15
作者
Afzelius, M
Bengtsson, PE
Bood, J
Brackmann, C
Kurtz, A
机构
[1] Lund Inst Technol, Div Combust Phys, S-22100 Lund, Sweden
[2] Univ Appl Sci Cologne, D-51643 Gummersbach, Germany
关键词
D O I
10.1364/AO.45.001177
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel technique for coherent anti-Stokes Raman spectroscopy (CARS) measurements in multiple points is presented. In a multipass cavity the pump and Stokes laser beams are multiply reflected and refocused into a measurement volume with an adjustable number of separated points along a line. This optical arrangement was used in a vibrational CARS setup with planar BOXCARS phase-matching configuration. The CARS spectra from spatially separated points were recorded at different heights on a CCD camera. Measurements of temperature profiles were carried out in the burned gas zone of a premixed one-dimensional flame to demonstrate the applicability of this method for temperature measurements in high-temperature regions. The ability to measure in flames with strong density gradients was demonstrated by simultaneous measurements of Q-branch spectra of N-2 and CO in a Wolfhard-Parker burner flame. Interference phenomena found in multipoint spectra are discussed, and possible solutions are proposed. Merits and limitations of the technique are discussed. (c) 2006 Optical Society of America.
引用
收藏
页码:1177 / 1186
页数:10
相关论文
共 17 条
[1]   ROTATIONAL CARS THERMOMETRY IN SOOTING FLAMES [J].
BENGTSSON, PE ;
MARTINSSON, L ;
ALDEN, M ;
KROLL, S .
COMBUSTION SCIENCE AND TECHNOLOGY, 1992, 81 (1-3) :129-140
[2]   SOOT PARTICLE MEASUREMENTS IN PREMIXED ETHYLENE FLAMES USING A PULSED LASER METHOD [J].
BENGTSSON, PE ;
ALDEN, M .
JOURNAL OF AEROSOL SCIENCE, 1988, 19 (07) :959-962
[3]   Multipoint temperature and oxygen-concentration measurements using rotational coherent anti-Stokes Raman spectroscopy [J].
Bood, J ;
Brackmann, C ;
Bengtsson, PE ;
Aldén, M .
OPTICS LETTERS, 2000, 25 (20) :1535-1537
[4]   SPATIAL AVERAGING AND MULTIPLEX COHERENT ANTI-STOKES RAMAN-SCATTERING TEMPERATURE-MEASUREMENT ERROR [J].
BOQUILLON, JP ;
PEALAT, M ;
BOUCHARDY, P ;
COLLIN, G ;
MAGRE, P ;
TARAN, JP .
OPTICS LETTERS, 1988, 13 (09) :722-724
[5]   Simultaneous vibrational and pure rotational coherent anti-Stokes Raman spectroscopy for temperature and multispecies concentration measurements demonstrated in sooting flames [J].
Brackmann, C ;
Bood, J ;
Bengtsson, PE ;
Seeger, T ;
Schenk, M ;
Leipertz, A .
APPLIED OPTICS, 2002, 41 (03) :564-572
[6]  
ECKBRETH AC, 1988, LASER DIAGNOSIS COMB
[7]  
GREENHALGH DA, 1988, ADV NONLINEAR SPECTR
[8]   One-dimensional vibrational coherent anti-Stokes Raman-scattering thermometry [J].
Jonuscheit, J ;
Thumann, A ;
Schenk, M ;
Seeger, T ;
Leipertz, A .
OPTICS LETTERS, 1996, 21 (19) :1532-1534
[9]   Accuracy and precision of single-pulse one-dimensional vibrational coherent anti-Stokes Raman-scattering temperature measurements [J].
Jonuscheit, J ;
Thumann, A ;
Schenk, M ;
Seeger, T ;
Leipertz, A .
APPLIED OPTICS, 1997, 36 (15) :3253-3260
[10]   AN EVALUATION OF PRECISION AND SYSTEMATIC-ERRORS IN VIBRATIONAL CARS THERMOMETRY [J].
KROLL, S ;
ALDEN, M ;
BENGTSSON, PE ;
LOFSTROM, C .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1989, 49 (05) :445-453