Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study

被引:83
作者
Kroll, Ryan R. [1 ]
Boyd, Gordon [1 ,2 ]
Maslove, David M. [1 ,2 ]
机构
[1] Queens Univ, Dept Med, Kingston, ON, Canada
[2] Queens Univ, Dept Crit Care Med, Kingston, ON, Canada
关键词
biometry/instrumentation; clothing; monitoring; physiologic; informatics; clinical trial; CLINICAL DETERIORATION; PREDICTION MODEL; CARDIAC-ARREST; VITAL SIGNS; PATIENT; WARDS; RISK; PAIN;
D O I
10.2196/jmir.6025
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. Objective: To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. Methods: We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo(2).R) was also measured as a positive control. Results: On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo(2).R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Conclusions: Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo(2).R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals.
引用
收藏
页数:11
相关论文
共 29 条
[1]   Mobile Phone-Connected Wearable Motion Sensors to Assess Postoperative Mobilization [J].
Appelboom, Geoff ;
Taylor, Blake E. ;
Bruce, Eliza ;
Bassile, Clare C. ;
Malakidis, Corinna ;
Yang, Annie ;
Youngerman, Brett ;
D'Amico, Randy ;
Bruce, Sam ;
Bruyere, Olivier ;
Reginster, Jean-Yves ;
Dumont, Emmanuel P. L. ;
Connolly, E. Sander, Jr. .
JMIR MHEALTH AND UHEALTH, 2015, 3 (03)
[2]   Mobile monitoring with wearable photoplethysmographic biosensors [J].
Asada, HH ;
Shaltis, P ;
Reisner, A ;
Rhee, S ;
Hutchinson, RC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03) :28-40
[3]   Big Data In Health Care: Using Analytics To Identify And Manage High-Risk And High-Cost Patients [J].
Bates, David W. ;
Saria, Suchi ;
Ohno-Machado, Lucila ;
Shah, Anand ;
Escobar, Gabriel .
HEALTH AFFAIRS, 2014, 33 (07) :1123-1131
[4]   Opportunities and challenges in the use of personal health data for health research [J].
Bietz, Matthew J. ;
Bloss, Cinnamon S. ;
Calvert, Scout ;
Godino, Job G. ;
Gregory, Judith ;
Claffey, Michael P. ;
Sheehan, Jerry ;
Patrick, Kevin .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2016, 23 (E1) :E42-E48
[5]   Clinical Applications of Wearable Technology [J].
Bonato, Paolo .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :6580-6583
[6]   Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data [J].
Case, Meredith A. ;
Burwick, Holland A. ;
Volpp, Kevin G. ;
Patel, Mitesh S. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (06) :625-626
[7]   Photoplethysmography variability as an alternative approach to obtain heart rate variability information in chronic pain patient [J].
Chuang, Chiung-Cheng ;
Ye, Jing-Jhao ;
Lin, Wan-Chun ;
Lee, Kuan-Ting ;
Tai, Yu-Ting .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (06) :801-806
[8]   Multicenter Comparison of Machine Learning Methods and Conventional Regression for Predicting Clinical Deterioration on the Wards [J].
Churpek, Matthew M. ;
Yuen, Trevor C. ;
Winslow, Christopher ;
Meltzer, David O. ;
Kattan, Michael W. ;
Edelson, Dana P. .
CRITICAL CARE MEDICINE, 2016, 44 (02) :368-374
[9]   Differences in Vital Signs Between Elderly and Nonelderly Patients Prior to Ward Cardiac Arrest [J].
Churpek, Matthew M. ;
Yuen, Trevor C. ;
Winslow, Christopher ;
Hall, Jesse ;
Edelson, Dana P. .
CRITICAL CARE MEDICINE, 2015, 43 (04) :816-822
[10]   Using Electronic Health Record Data to Develop and Validate a Prediction Model for Adverse Outcomes in the Wards [J].
Churpek, Matthew M. ;
Yuen, Trevor C. ;
Park, Seo Young ;
Gibbons, Robert ;
Edelson, Dana P. .
CRITICAL CARE MEDICINE, 2014, 42 (04) :841-848