Evaluation of bonding effectiveness of a self-etch and an etch-and-rinse adhesive resin to un-treated and Er:Yag laser treated dentin using mini-interfacial fracture toughness test

被引:1
作者
Behroozibakhsh, Marjan [1 ,2 ]
Davaie, Sotoudeh [1 ,2 ]
Monzavi, Abbas [3 ,4 ]
Abazari, Tayebeh [5 ]
Shahabi, Sima [1 ,3 ,4 ]
Pirmoradian, Maryam [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Sch Dent, Dept Dent Biomat, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[3] Univ Tehran Med Sci, Dent Res Inst, LRCD, Tehran, Iran
[4] Univ Tehran Med Sci, Dent Res Inst, Dent Res Ctr, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Dent, Tehran, Iran
关键词
Bonding effectiveness; Er; Yag laser; etch-and-rinse; mini-iFT; self-etch; COMPOSITE; STRENGTH; MECHANICS; FAILURE; ENAMEL;
D O I
10.1080/01694243.2019.1581391
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The aim of current study was to assess interfacial bonding effectiveness of self-etch and etch-and-rinse dental adhesives to untreated and Er:YAG laser-treated dentine using mini-interfacial fracture toughness (mini-iFT) test. 32 selected non-carious third molars were divided into two groups: untreated and Er:YAG laser treated. The laser-treated specimens were subjected to Er:YAG laser with energy density of 25.82 J/cm(2). Both groups were further assigned to two groups based on adhesive systems: self-etch and etch-and-rinse. The teeth were sectioned perpendicular to the adhesive/dentine interface to obtain 1.5 x 2 mm wide longitudinal rectangular sections. A single notch then was prepared at the adhesive-dentine interface. The mini-iFT test was done via a 4-point bend testing until failure and the KIC was calculated. All specimens were observed using a, scanning electron microscope (SEM). The data were analysed using two-way analysis of variance (ANOVA) at a significant level of 0.05. Weibull parameters including Weibull modulus and characteristic strength also were calculated for each experimental group. Two-way ANOVA showed both variables (the type of adhesive system and laser treatment) significantly influenced the mini-iFT values of specimens (p <= 0.001). The self-etch and laser-treated group showed lower mini-iFT than the etch-and-rinse and untreated samples. SEM observations revealed that the fracture region was located at the adhesive-dentine interface in most of the specimens. The Er:YAG laser treatment may adversely affects the bonding effectiveness of the dentine/adhesive interface. The mini-iFT method can be used as a discriminative and valid method for the evaluation of bonding effectiveness at the adhesive-dentine interface.
引用
收藏
页码:1201 / 1214
页数:14
相关论文
共 44 条
[21]   Fracture mechanics of dental adhesives supplemented with Polymethyl-vinyl-ether-co-maleic anhydride [J].
Kim, Chris S. ;
Ozer, Fusun ;
Mante, Francis K. .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2017, 31 (10) :1116-1124
[22]  
Koliniotou-koumpia E, 2012, EUR J DENT, V6, P16
[23]  
Lee H-E, 2007, J KOREAN ACAD CONSER, V32, P9
[24]   FAILURE MECHANISMS AT THE HUMAN DENTIN-RESIN INTERFACE - A FRACTURE-MECHANICS APPROACH [J].
LIN, CP ;
DOUGLAS, WH .
JOURNAL OF BIOMECHANICS, 1994, 27 (08) :1037-1047
[25]   Dental Adhesion to Erbium-Lased Tooth Structure: A Review of the Literature [J].
Lopes, Raquel Marianna ;
Trevelin, Livia Tosi ;
Barros da Cunha, Sandra Ribeiro ;
de Oliveira, Renata Ferreira ;
Richarte de Andrade Salgado, Daniela Miranda ;
Moreira de Freitas, Patricia ;
Eduardo, Carlos de Paula ;
Correa Aranha, Ana Cecilia .
PHOTOMEDICINE AND LASER SURGERY, 2015, 33 (08) :393-403
[26]   A review of adhesion science [J].
Marshall, Sally J. ;
Bayne, Stephen C. ;
Baier, Robert ;
Tomsia, Antoni P. ;
Marshall, Grayson W. .
DENTAL MATERIALS, 2010, 26 (02) :E11-E16
[27]   THE PROMOTION OF ADHESION BY THE INFILTRATION OF MONOMERS INTO TOOTH SUBSTRATES [J].
NAKABAYASHI, N ;
KOJIMA, K ;
MASUHARA, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (03) :265-273
[28]  
Nassif M, 2013, NANOBIOMATERIALS IN CLINICAL DENTISTRY, P131
[29]   CLINICAL CORRELATIONS OF DENTIN STRUCTURE AND FUNCTION [J].
PASHLEY, DH .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 66 (06) :777-781
[30]  
Pelagalli J, 1997, J CLIN LASER MED SUR, V15, P10915