Theoretical Analysis on Strain Transfer Error of FBG Sensors Attached on Steel Structures Subjected to Fatigue Load

被引:61
作者
Wang, H. P. [1 ,2 ]
Xiang, P. [3 ]
Li, X. [4 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[2] Dalian Univ Technol, Sch Civil Engn, Dalian 116024, Peoples R China
[3] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Hong Kong, Peoples R China
[4] Carnegie Mellon Univ, Dept Civil & Environm Engn, Pittsburgh, PA 15213 USA
关键词
error modification; fatigue load; FBG sensor; sensitive parameter; strain transfer theory; OPTICAL-FIBER SENSORS; BRAGG GRATING SENSORS;
D O I
10.1111/str.12195
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fibre Bragg grating (FBG) sensors have been increasingly adopted to detect the dynamic strain of structures. When the sensor is attached on the surface, adhesive material is employed to assist the installation, which leads to indirect contact of sensing fibre and the monitored structure. To correct the strain transfer error induced by the shear lag effect and improve the measurement accuracy of FBG sensors under dynamic response, strain transfer mechanism of a three-layered testing model constituted of sensing fibre, adhesive layer and host material has been studied in this paper. Laboratory test on steel beam attached with FBG sensor under fatigue load has been projected to investigate the feasibility of the derived strain transfer formula, and numerical simulation by MATLAB has been used as a supporting tool to offer the reference dynamic strain. Based on the analysis, sensitive parameters that affect the strain transfer coefficient have been discussed to instruct the application design of FBG sensors. Results indicate that strain transfer coefficient under dynamic response is much lower than that in static state, and error modification is particularly significant; in the dynamic testing model, bonded length, shear modulus and thickness of adhesive layer are more sensitive, which should be precisely selected in practical engineering to guarantee the effective strain measurement.
引用
收藏
页码:522 / 530
页数:9
相关论文
共 30 条
[1]  
[Anonymous], GUIDELINES STRUCTURA
[2]  
[Anonymous], SPIE SMART SENSOR PH
[3]  
[Anonymous], OPTICAL ENG
[4]  
[Anonymous], MEASUREMENT SCI TECH
[5]  
[Anonymous], 2015, Thesis
[6]   Mechanics of bond and interface shear transfer in optical fiber sensors [J].
Ansari, F ;
Libo, Y .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1998, 124 (04) :385-394
[7]   Practical implementation of optical fiber sensors in civil structural health monitoring [J].
Ansari, Farhad .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2007, 18 (08) :879-889
[8]   Development of a FBG based distributed strain sensor system for wind turbine structural health monitoring [J].
Arsenault, Tyler J. ;
Achuthan, Ajit ;
Marzocca, Pier ;
Grappasonni, Chiara ;
Coppotelli, Giuliano .
SMART MATERIALS AND STRUCTURES, 2013, 22 (07)
[9]   Fatigue Life Estimation of Structural Components Using Macrofibre Composite Sensors [J].
Butrym, B. A. ;
Kim, M. H. ;
Inman, D. .
STRAIN, 2012, 48 (03) :190-197
[10]   STRESS DISTRIBUTIONS ALONG A SHORT FIBER IN FIBER REINFORCED-PLASTICS [J].
CHON, CT ;
SUN, CT .
JOURNAL OF MATERIALS SCIENCE, 1980, 15 (04) :931-938